《ASTM D6584-2017 red 5625 Standard Test Method for Determination of Total Monoglycerides Total Diglycerides Total Triglycerides and Free and Total Glycerin in B-100 Biodiesel Methyl.pdf》由会员分享,可在线阅读,更多相关《ASTM D6584-2017 red 5625 Standard Test Method for Determination of Total Monoglycerides Total Diglycerides Total Triglycerides and Free and Total Glycerin in B-100 Biodiesel Methyl.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6584 131D6584 17Standard Test Method forDetermination of Total Monoglycerides, Total Diglycerides,Total Triglycerides, and Free and Total Glycerin in B-100Biodiesel Methyl Esters by Gas Chromatography1This standard is issued under the fixed designation D6584; the number immediately fol
2、lowing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEThe formats of Eq 11
3、and Eq 16 were editorially corrected in April 2014.1. Scope*1.1 This test method covers the quantitative determination of total monoglyceride, total diglyceride, total triglyceride, and freeand total glycerin in B-100 methyl esters by gas chromatography. The range of quantitation for monoglyceride i
4、s 0.009 to 0.77860mass %,0.009 % to 0.77860 % by mass, for diglyceride is 0.092353 to 0.54475 mass %,% to 0.54475 % by mass, and fortriglyceride is 0.00092857 to 1.3881 mass %.0.00092857 % to 1.3881 % by mass. The range of quantitation for free glycerin is0.00057140.0005714 % to 0.019533 0.019533 %
5、by mass % and for total glycerin from 0.0090714 to 0.42767 mass%.0.0090714 % to 0.42767 % by mass. This procedure is not applicable to vegetable oil methyl esters obtained from lauric oils,such as coconut oil and palm kernel oil.1.2 The values stated in SI units are to be regarded as standard. No ot
6、her units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability
7、of regulatorylimitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade
8、 Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D4307 Practice for Preparation of Liquid Blends for Use as Analytical StandardsE355 Practice for Gas Chromatography Terms and RelationshipsE594 Practice for Testing Flame Ionization Detectors Used in
9、 Gas or Supercritical Fluid Chromatography3. Terminology3.1 Definitions:3.1.1 biodiesel (B-100), nfuel comprised of mono-alkyl esters of long chain fatty acids derived from vegetable oils or animalfats.3.1.2 bonded glycerin, nglycerin portion of the mono-, di-, and triglyceride molecules.3.2 Definit
10、ions of Terms Specific to This Standard:3.2.1 total glycerin, nsum of free and bonded glycerin.3.3 This test method makes reference to many common gas chromatographic procedures, terms, and relationships. Detaileddefinitions can be found in Practices E355 and E594.1 This test method is under the jur
11、isdiction of ASTM Committee D02 on Petroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility of D02.04.0Lon Gas Chromatography Methods.Current edition approved May 1, 2013June 1, 2017. Published May 2013July 2017. Originally approved in 2000. Last previous edition approved in
12、 20102013 asD6584D6584 1310a1. DOI: 10.1520/D6584-13E01.10.1520/D6584-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the A
13、STM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consu
14、lt prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
15、PA 19428-2959. United States14. Summary of Test Method4.1 The sample is analyzed by gas chromatography, after silyating with N-methyl-N-trimethylsilyltrifluoracetamide (MSTFA).Calibration is achieved by the use of two internal standards and four reference materials. Mono-, di-, and triglyceride ared
16、etermined by comparing to monoolein, diolein, and triolein standards respectively. Average conversion factors are applied tomono-, di-, and triglycerides to calculate the bonded glycerin content of the sample.5. Significance and Use5.1 Free and bonded glycerin content reflects the quality of biodies
17、el.Ahigh content of free glycerin may cause problems duringstorage, or in the fuel system, due to separation of the glycerin. A high total glycerin content can lead to injector fouling and mayalso contribute to the formation of deposits at injection nozzles, pistons, and valves.6. Apparatus6.1 Chrom
18、atographic SystemSee Practice E355 for specific designations and definitions.6.1.1 Gas Chromatograph (GC)The system must be capable of operating at the conditions given in Table 1.6.1.2 Column, open tubular column with a 5 % phenylpolydimethylsiloxane bonded and cross linked phase internal coating.T
19、hecolumn should have an upper temperature limit of at least 400C.400 C. Columns, either 10 m or 15 m 10 m or 15 m in length,with a 0.32 mm 0.32 mm internal diameter, and a 0.1 m 0.1 m film thickness have been found satisfactory. Any column withbetter or equivalent chromatographic efficiency and sele
20、ctivity can be used. It is recommended that a 2 to 5 metre 0.53 mm 2 mto 5 m-0.53 mm high temperature guard column be installed from the injector to the analytical column. This allows the use ofautoinjectors and also increases column life.6.2 Electronic Data Acquisition System:6.2.1 Integrator or Co
21、mputer, capable of providing real time graphic and digital presentation of the chromatographic data isrecommended for use. Peak areas and retention times shall be measured by computer or electronic integration.6.2.2 This device must be capable of performing multilevel internal-standard-type calibrat
22、ions and be able to calculate thecorrelation coefficient (r2) and internal standard calculations for each data set.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that allreagents conform to the specificati
23、ons of the Committee on Analytical Reagents of the American Chemical Society where suchspecifications are available.3 Other grades may be used provided it is first ascertained that the reagent is of sufficient purity topermit its use without lessening the accuracy of the determination.7.2 n-Heptane,
24、 reagent grade.7.3 N-Methyl-N-trimethylsilyltrifluoroacetamide (MSTFA), reagent grade.7.4 Pyridine, reagent grade.3 Reagent Chemicals, American Chemical Society Specifications, American Chemical Society, Washington, DC. For Suggestions on the testing of reagents not listed bythe American Chemical So
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD65842017RED5625STANDARDTESTMETHODFORDETERMINATIONOFTOTALMONOGLYCERIDESTOTALDIGLYCERIDESTOTALTRIGLYCERIDESANDFREEANDTOTALGLYCERININB100BIODIESELMETHYLPDF

链接地址:http://www.mydoc123.com/p-522942.html