ASTM D6584-2010ae1 3750 Standard Test Method for Determination of Total Monoglyceride Total Diglyceride Total Triglyceride and Free and Total Glycerin in B-100 Biodiesel Methyl Est.pdf
《ASTM D6584-2010ae1 3750 Standard Test Method for Determination of Total Monoglyceride Total Diglyceride Total Triglyceride and Free and Total Glycerin in B-100 Biodiesel Methyl Est.pdf》由会员分享,可在线阅读,更多相关《ASTM D6584-2010ae1 3750 Standard Test Method for Determination of Total Monoglyceride Total Diglyceride Total Triglyceride and Free and Total Glycerin in B-100 Biodiesel Methyl Est.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6584 10a1Standard Test Method forDetermination of Total Monoglycerides, Total Diglycerides,Total Triglycerides, and Free and Total Glycerin in B-100Biodiesel Methyl Esters by Gas Chromatography1This standard is issued under the fixed designation D6584; the number immediately following
2、the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTECorrected formatting and spac
3、ing in Eqs 12-19 and added previous Summary of Changes editorially in March 2011.1. Scope*1.1 This test method covers the quantitative determinationof total monoglyceride, total diglyceride, total triglyceride, andfree and total glycerin in B-100 methyl esters by gas chroma-tography. The range of qu
4、antitation for monoglyceride is 0.100to 1.000 mass %, for diglyceride is 0.050 to 0.500 mass %, andfor triglyceride is 0.050 to 0.500 mass %. The range ofquantitation for free glycerin is 0.005 to 0.05 mass % and fortotal glycerin from 0.05 to 0.5 mass %. This procedure is notapplicable to vegetable
5、 oil methyl esters obtained from lauricoils, such as coconut oil and palm kernel oil.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated
6、 with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D4307 Practice for Preparation of Liquid Blends for Use asAnaly
7、tical StandardsE355 Practice for Gas Chromatography Terms and Rela-tionshipsE594 Practice for Testing Flame Ionization Detectors Usedin Gas or Supercritical Fluid Chromatography3. Terminology3.1 Definitions:3.1.1 biodiesel (B-100), nfuel comprised of mono-alkylesters of long chain fatty acids derive
8、d from vegetable oils oranimal fats.3.1.2 bonded glycerin, nglycerin portion of the mono-,di-, and triglyceride molecules.3.2 Definitions of Terms Specific to This Standard:3.2.1 total glycerin, nsum of free and bonded glycerin.3.3 This test method makes reference to many common gaschromatographic p
9、rocedures, terms, and relationships. Detaileddefinitions can be found in Practices E355 and E594.4. Summary of Test Method4.1 The sample is analyzed by gas chromatography, aftersilyating with N-methyl-N-trimethylsilyltrifluoracetamide(MSTFA). Calibration is achieved by the use of two internalstandar
10、ds and four reference materials. Mono-, di-, and trig-lyceride are determined by comparing to monoolein, diolein,and triolein standards respectively. Average conversion factorsare applied to mono-, di-, and triglycerides to calculate thebonded glycerin content of the sample.5. Significance and Use5.
11、1 Free and bonded glycerin content reflects the quality ofbiodiesel. A high content of free glycerin may cause problemsduring storage, or in the fuel system, due to separation of theglycerin. A high total glycerin content can lead to injectorfouling and may also contribute to the formation of deposi
12、ts atinjection nozzles, pistons, and valves.6. Apparatus6.1 Chromatographic SystemSee Practice E355 for spe-cific designations and definitions.6.1.1 Gas Chromatograph (GC)The system must be ca-pable of operating at the conditions given in Table 1.6.1.2 Column, open tubular column with a 5 % phenylpo
13、ly-dimethylsiloxane bonded and cross linked phase internal coat-ing. The column should have an upper temperature limit of atleast 400C. Columns, either 10 m or 15 m in length, with a0.32 mm internal diameter, and a 0.1 m film thickness havebeen found satisfactory. Any column with better or equivalen
14、t1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of D02.04.0L onGas Chromatography Methods.Current edition approved Nov. 1, 2010. Published January 2011. Originallyapproved in 2000. Last previous edition approved
15、in 2010 as D658410. DOI:10.1520/D6584-10A.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Chan
16、ges section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.chromatographic efficiency and selectivity can be used. It isrecommended thata2to5metre 0.53 mm high temperatureguard column be installed
17、from the injector to the analyticalcolumn. This allows the use of autoinjectors and also increasescolumn life.6.2 Electronic Data Acquisition System:6.2.1 Integrator or Computer, capable of providing realtime graphic and digital presentation of the chromatographicdata is recommended for use. Peak ar
18、eas and retention timesshall be measured by computer or electronic integration.6.2.2 This device must be capable of performing multilevelinternal-standard-type calibrations and be able to calculate thecorrelation coefficient (r2) and internal standard calculationsfor each data set.7. Reagents and Ma
19、terials7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.3Other grades may b
20、e usedprovided it is first ascertained that the reagent is of sufficientpurity to permit its use without lessening the accuracy of thedetermination.7.2 n-Heptane, reagent grade.7.3 N-Methyl-N-trimethylsilyltrifluoroacetamide (MSTFA),reagent grade.7.4 Pyridine, reagent grade.7.5 Carrier Gas, hydrogen
21、 or helium of high purity. Addi-tional purification is recommended by the use of molecularsieves or other suitable agents to remove water, oxygen, andhydrocarbons. Available pressure must be sufficient to ensure aconstant carrier gas flow rate.7.6 Microlitre Syringes, 100 L and 250 L capacity.7.7 Sc
22、rew Cap Vials, with polytetrafluoroethylene (PTFE)-faced septa, 10 mL capacity.8. Preparation of Apparatus8.1 Install and condition the column in accordance withmanufacturer or suppliers instructions. After conditioning,attach column outlet to flame ionization detector inlet andcheck for leaks throu
23、ghout the system. If leaks are found,tighten or replace fittings and recheck for leaks before proceed-ing.9. Calibration and Standardization9.1 Preparation of Calibration StandardsPrepare stan-dards using fresh compounds listed in Table 2 according toPractice D4307. Weigh the components directly int
24、o thevolumetric flasks specified and record the mass to the nearest0.1 mg. Dilute the volumetric flasks to mark with pyridine.Store the calibration standards in a refrigerator when not in use.9.2 Standard SolutionsPrepare the five standard solutionsin Table 3 by transferring the specified volumes by
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD65842010AE13750STANDARDTESTMETHODFORDETERMINATIONOFTOTALMONOGLYCERIDETOTALDIGLYCERIDETOTALTRIGLYCERIDEANDFREEANDTOTALGLYCERININB100BIODIESELMETHYLESTPDF

链接地址:http://www.mydoc123.com/p-522939.html