ASTM D5928-1996(2010)e1 1875 Standard Test Method for Screening of Waste for Radioactivity《放射性废弃物筛选的标准试验方法》.pdf
《ASTM D5928-1996(2010)e1 1875 Standard Test Method for Screening of Waste for Radioactivity《放射性废弃物筛选的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5928-1996(2010)e1 1875 Standard Test Method for Screening of Waste for Radioactivity《放射性废弃物筛选的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5928 96 (Reapproved 2010)1Standard Test Method forScreening of Waste for Radioactivity1This standard is issued under the fixed designation D5928; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial changes were made throughout in January 2010.1. Scope1.1 This test method covers the screening for a, b, and gradiation above
3、ambient background levels or user-definedcriteria, or both, in liquid, sludge, or solid waste materials.1.2 This test method is intended to be a gross screeningmethod for determining the presence or absence of radioactivematerials in liquid, sludge, or solid waste materials. It is notintended to rep
4、lace more sophisticated quantitative analyticaltechniques, but to provide a method for rapidly screeningsamples for radioactivity above ambient background levels oruser-defined criteria, or both, for facilities prohibited fromhandling radioactive waste.1.3 This test method may not be suitable for ap
5、plicationssuch as site assessments and remediation activities.1.4 The values stated in SI units are to be regarded as thestandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establis
6、h appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C859 Terminology Relating to Nuclear Materials3. Terminology3.1 For terminology related to radioactive materials, seeTerminology C859.4. Summa
7、ry of Test Method4.1 Asample is held within 6 mm of the detector window ofa radiation survey meter, and the visible or audible reaction ofthe meter, or both, is noted. The user defines an application/project specific “negative” and “positive” result criteria. A“negative” test result indicates radiat
8、ion levels are below theuser-established criteria; a “positive” test result indicates theradiation levels are above the user-established criteria.5. Significance and Use5.1 Most facilities disposing or utilizing waste materials areprohibited from handling wastes that contain radioactive ma-terials.
9、This test method provides the user a rapid method forscreening waste material samples in the field or laboratory forthe presence or absence of radioactivity at user-establishedcriteria. It is important to these facilities to be able to verifygenerator-supplied information that radioactive or mixedwa
10、stes have not been included in shipments of waste materials.6. Interferences6.1 Needle deflections or audible clicks of the survey meter,or both, occur due to naturally occurring omni-directionalbackground radiation. This level of ambient background radia-tion should be periodically assessed. See Se
11、ction 10.6.2 Possible sources of interference include pacemakers,X-ray generating equipment, radium-based luminescent dials,polonium-based static eliminators, and smoke detectors con-taining a radioactive isotope sensing mechanism. Such inter-ferences can usually be traced to their source using the
12、portableinstrument specified in this test method.6.3 A large amount of potassium in the waste sample mayproduce a positive result due to the natural presence of theradioactive isotope, Potassium-40.6.4 The sensitivity of this test method to beta and gammaradiation may be dependent on sample volume.A
13、small samplevolume with readings near background levels may give a falsenegative result.6.5 Some radioactive isotopes, such as3H and14C, may notemit radiation of sufficient energy to be detected. If suspectedto be present in the waste, another procedure should be usedthat is appropriate to their det
14、ermination.6.6 Liquid samples, as well as moisture in solid samples, aregood attenuators of radiation and will hinder detection of manyradionuclides unless they emit high-energy gamma radiation.The possible inability to detect alpha particles and low-level1This test method is under the jurisdiction
15、of ASTM Committee D34 on WasteManagement and is the direct responsibility of Subcommittee D34.01.05 onScreening Methods.Current edition approved Jan. 1, 2010. Published January 2010. Originallyapproved in 1996. Last previous edition approved in 2003 as D5928 96(2003).DOI: 10.1520/D5928-96R10E01.2For
16、 referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700
17、, West Conshohocken, PA 19428-2959, United States.beta emissions that may be attenuated, in many cases, shouldnot be a serious shortcoming in this test method because theseemissions are often accompanied by higher energy gammaemissions.6.6.1 Moisture-laden Americium-241 bearing waste wouldbe a case
18、where there is a high probability of non-detection dueto attenuation.6.7 Survey meter contamination can cause artificially low orhigh results when reading standard sources or ambient back-ground. If this occurs, the survey meter performance shall beconsidered unreliable and should be appropriately d
19、econtami-nated by qualified personnel, or disposed of in accordance withapplicable regulations.6.8 The radiation monitor should be operated in accordancewith the manufacturers instructions.7. Apparatus7.1 Radiation Survey Meter, with a halogen-quenched un-compensated Geiger-Mueller tube with thin mi
20、ca end-window.It is advisable to choose an instrument model that has aninternal counter (cpm) or is capable of operating in a scalermode.NOTE 1The meter used in the development of this test method wasthe Monitor 4.3A number of other survey meters4are suitable for this testmethod. Through the end-win
21、dow, this unit is capable of detecting andindicating alpha radiation (down to 2.5 MeV with a typical detectionefficiency of 80 % at 3.6 MeV), beta radiation (down to 150 KeV with atypical 75 % detection efficiency), gamma radiation and X-rays (down to10 KeV), with the survey meter set on its lowest
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD592819962010E11875STANDARDTESTMETHODFORSCREENINGOFWASTEFORRADIOACTIVITY 放射性 废弃物 筛选 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-521074.html