ASTM D5666-1995(2004)e1 Standard Test Method for P-Phenylenediamine Antidegradants-Purity by High Performance Liquid Chromatography《使用高效液相色谱的P-苯二胺抗降解剂纯度的标准试验方法》.pdf
《ASTM D5666-1995(2004)e1 Standard Test Method for P-Phenylenediamine Antidegradants-Purity by High Performance Liquid Chromatography《使用高效液相色谱的P-苯二胺抗降解剂纯度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5666-1995(2004)e1 Standard Test Method for P-Phenylenediamine Antidegradants-Purity by High Performance Liquid Chromatography《使用高效液相色谱的P-苯二胺抗降解剂纯度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5666 95 (Reapproved 2004)e1Standard Test Method forRubber Chemical AntidegradantsPurity ofp-Phenylenediamine (PPD) Antidegradants by HighPerformance Liquid Chromatography1This standard is issued under the fixed designation D 5666; the number immediately following the designation indic
2、ates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEThe title was revised editorially in December 20
3、04.1. Scope1.1 This test method covers the purity of Type I, II, and IIIp-phenylenediamine (PPD) antidegradants as described inPractice D 4676 by high performance liquid chromatography(HPLC) using ultraviolet detection and external standardcalculations.1.2 Expertise in HPLC is necessary to the succe
4、ssful appli-cation of this test method.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory l
5、imitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 3853 Terminology Relating to Rubber and RubberLaticesAbbreviations for Chemicals Used in Com-poundingD 4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesD 4676 Cla
6、ssification for Rubber CompoundingMaterialsAntidegradants2.2 ISO Standards:3ISO 5725 Precision of Test MethodsISO 6472 Rubber Compounding IngredientsAbbreviations3. Terminology3.1 Definitions:3.1.1 external standard calculationa method of calculat-ing the percent composition by measuring the area of
7、 theanalyte peak, multiplying by a response factor, and dividing bythe sample concentration. All components are assumed to beresolved from the component of interest.3.1.2 lot samplea production sample representative of astandard production unit, normally referred to as the sample.3.1.3 specimenthe a
8、ctual material used in the analysis,also known as the test portion. It must be representative of thelot sample.3.2 Abbreviations: The following abbreviations are in ac-cordance with Terminology D 3853 and ISO 6472:3.2.1 77PDN,N8 bis-(1,4-dimethylpentyl)-p-phenylene-diamine.3.2.2 DTPDN,N8-ditolyl-p-p
9、henylenediamine.3.2.3 IPPDN-isopropyl-N8-phenyl- p-phenylenediamine.3.2.4 PPDp-phenylenediamine.3.2.5 6PPDN-(1,3 dimethylbutyl)-N8-phenyl-p-phenyl-enediamine.4. Summary of Test Method4.1 A specimen is dissolved in acetonitrile and a fixed loopvolume is analyzed by isocratic HPLC using a thermostated
10、C18 reversed phase column and an ultraviolet (UV) detector.Peak areas are determined using a chromatographic integratoror laboratory data system with the amount of analyte beingdetermined by external calibration.5. Significance and Use5.1 This test method is designed to determine the purity ofp-phen
11、ylenediamine antidegradants.1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.11 on Chemical Analysis.Current edition approved Dec. 1, 2004. Published December 2004. Originallyapproved in 1995. Last previous edition approv
12、ed in 2000 as D 5666 - 95 (2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Nat
13、ional Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 Since the results of this test method are based on anintegrated peak area as determined by HPLC, it is
14、 assumed thatall analytes of interest are resolved from interfering peaks.6. Interferences6.1 Components co-eluting with the analyte of interest willcause erroneous results; thus it is required that the system becapable of providing a minimum of 10 000 theoretical plates.7. Apparatus7.1 Liquid Chrom
15、atograph, consisting of the following:7.1.1 Precision chromatographic pump,7.1.2 Variable wavelength UV detector,7.1.3 A method for thermostating the column at 35 6 1C,for example, a column oven or water jacket,7.1.4 A fixed injector made of either a 20 mm3(L)rheodyne loop or an automatic sampler.7.
16、2 HPLC Columns, consisting of:7.2.1 A precolumn packed with C18 grafted silica withparticle size of 35 to 40 m (100 to 150 mm), and7.2.2 A column of 10- to 15-cm length packed with C18grafted silica with particle size of 3 to 5 m.7.3 Integrator/Data System, capable of determining abso-lute amounts o
17、f analyte of interest by means of integration ofdetector output versus time.7.4 Analytical Balance, capable of measuring within 60.01mg.7.5 Shaking Machine, or ultrasonic tank.7.6 Volumetric Flask, 100 cm3.7.7 Syringes, with rheodyne loop, 2 cm3.7.8 Clear Screw-Top Vials, with suitable septa, 125 cm
18、3.8. Reagents and Materials8.1 Acetonitrile, HPLC grade.8.2 Ethanolamine, HPLC grade.8.3 Water, HPLC grade or double distilled water or water ofresistivity greater than 2 megohms/cm.9. Calibration and Standardization9.1 Aprimary standard of known purity is used to determinethe response factor for ea
19、ch analyte.10. Procedure10.1 Chromatographic Conditions:10.1.1 Determine the eluant phase composition and the flowrate by adjusting the chromatographic parameters for theparticular column chosen. The eluant phase consists of theappropriate mixture of HPLC grade acetonitrile and HPLCgrade or equivale
20、nt water, both containing 0.2 kg/m3(g/L)ethanolamine or less according to the product to be tested.NOTE 1Different liquid chromatography columns may exhibit differ-ent elution characteristics. See Table 1 for suggested chromatographicstarting parameters for analysis.10.2 DetectorMonitor the absorban
21、ce of the sample at theprescribed wavelength. The detector should be set to 1 absor-bance unit full scale (AUFS).10.3 Integrator/Data SystemThe integrator settingsshould be adjusted to give a full-scale response to 1 absorbanceunit (AU).10.4 Sample Storage Before AnalysisSamples must al-ways be stor
22、ed in a refrigerator.10.5 Standard PreparationWeigh the clear vial to thenearest 0.1 mg, introduce approximately 20 mg of the standardusing a spatula and weigh the standard and vial to the nearest0.1 mg. Using a volumetric flask, add 100 cm3of acetonitrileto the vial. Stopper the vial so that it is
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD566619952004E1STANDARDTESTMETHODFORPPHENYLENEDIAMINEANTIDEGRADANTSPURITYBYHIGHPERFORMANCELIQUIDCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-520387.html