ASTM D5600-2014 Standard Test Method for Trace Metals in Petroleum Coke by Inductively Coupled Plasma Atomic Emission Spectrometry &40 ICP-AES&41 《感应耦合等离子体原子发射光谱法(ICP-AES)分析石油焦炭中痕量.pdf
《ASTM D5600-2014 Standard Test Method for Trace Metals in Petroleum Coke by Inductively Coupled Plasma Atomic Emission Spectrometry &40 ICP-AES&41 《感应耦合等离子体原子发射光谱法(ICP-AES)分析石油焦炭中痕量.pdf》由会员分享,可在线阅读,更多相关《ASTM D5600-2014 Standard Test Method for Trace Metals in Petroleum Coke by Inductively Coupled Plasma Atomic Emission Spectrometry &40 ICP-AES&41 《感应耦合等离子体原子发射光谱法(ICP-AES)分析石油焦炭中痕量.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5600 09D5600 14Standard Test Method forTrace Metals in Petroleum Coke by Inductively CoupledPlasma Atomic Emission Spectrometry (ICP-AES)1This standard is issued under the fixed designation D5600; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the analysis for commonly determined trace metals in
3、test specimens of raw and calcined petroleumcoke by inductively coupled plasma atomic emission spectroscopy.1.2 Elements for which this test method is applicable are listed in Table 1. Detection limits, sensitivity, and optimum ranges ofthe metals will vary with the matrices and model of spectromete
4、r.1.3 This test method is applicable only to samples containing less than one mass % ash.1.4 Elements present at concentrations above the upper limit of the working ranges can be determined with additional,appropriate dilutions.1.5 The values stated in SI units are to be regarded as the standard. Th
5、e values given in parentheses are for information only.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability
6、of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D346 Practice for Collection and Preparation of Coke Samples for Laboratory AnalysisD1193 Specification for Reagent WaterD7260 Practice for Optimization, Calibration, and Validation of Inductively Coupled Plasma-Atomic
7、Emission Spectrometry(ICP-AES) for Elemental Analysis of Petroleum Products and LubricantsE11 Specification for Woven Wire Test Sieve Cloth and Test Sieves3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 gross samplethe original, uncrushed, representative portion taken from a s
8、hipment or lot of coke.3.1.2 ICP-AESInductively Coupled PlasmaAtomic Emission Spectrometry.3.1.3 petroleum cokea solid, carbonaceous residue produced by thermal decomposition of heavy petroleum fractions andcracked stocks.4. Summary of Test Method4.1 A test sample of the petroleum coke is ashed at 7
9、00C. The ash is fused with lithium borate. The melt is dissolved in dilutehydrochloric acid (HCl), and the resultant solution is analyzed by inductively coupled plasma atomic emission spectrometry(ICP-AES) using simultaneous, or sequential multielemental determination of elements. The solution is in
10、troduced to the ICPinstrument by free aspiration or by an optional peristaltic pump. The concentrations of the trace metals are then calculated bycomparing the emission intensities from the sample with the emission intensities of the standards used in calibration.1 This test method is under the juri
11、sdiction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuels, and Lubricantsand is the direct responsibility ofSubcommittee D02.03 on Elemental Analysis.Current edition approved Oct. 1, 2009June 1, 2014. Published November 2009 July 2014. Originally approved in 1994. Last previous edi
12、tion approved in 20042009 asD5600D5600 09.04 1. DOI: 10.1520/D5600-09.10.1520/D5600-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary
13、 page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends th
14、at users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
15、Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 The presence and concentration of various metallic elements in a petroleum coke are major factors in determining thesuitability of the coke for various end uses. This test method provides a means of determining the concentrations
16、of these metallicelements in a coke sample.5.2 The test method provides a standard procedure for use by buyer and seller in the commercial transfer of petroleum coke todetermine whether the petroleum coke meets the specifications of the purchasing party.6. Interferences6.1 SpectralFollow the instrum
17、ent manufacturers operating guide to develop and apply correction factors to compensate forthe interferences. To apply interference corrections, all concentrations shall be within the previously established linear responserange of each element.6.2 Spectral interferences are caused by: (1) overlap of
18、 a spectral line from another element; (2) unresolved overlap of molecularband spectra; (3) background contribution from continuous or recombination phenomena; and (4) stray light from the line emissionof high-concentration elements. Spectral overlap can be compensated for by computer-correcting the
19、 raw data after monitoring andmeasuring the interfering element. Unresolved overlap requires selection of an alternate wavelength. Background contribution andstray light can usually be compensated for by a background correction adjacent to the analyte line.6.3 Physical interferences are effects asso
20、ciated with the sample nebulization and transport processes. Changes in viscosity andsurface tension can cause significant inaccuracies, especially in samples containing high dissolved solids or high acidconcentrations. If physical interferences are present, they shall be reduced by diluting the sam
21、ple, by using a peristaltic pump, orby using the standard additions method. Another problem that can occur with high dissolved solids is salts buildup at the tip ofthe nebulizer, which can affect aerosol flow rate and cause instrumental drift. This problem can be controlled by wetting the argonprior
22、 to nebulization, using a tip washer, or diluting the sample.6.4 See Practice D7260 for explanation of ICP-AES interferences and other operational details.7. Apparatus7.1 Balance, top loading, with automatic tare, capable of weighing to 0.0001 g, 150 g capacity.7.2 Ceramic Cooling Plate, desiccator
23、plates have been found effective.7.3 Crucible Support, nichrome wire triangles.7.4 Furnaces, electric, capable of regulation of temperature at 700 6 10C and 1000 6 10C, with allowances for exchangeof combustion gases and air.7.5 Inductively Coupled Plasma Atomic Emission SpectrometerEither sequentia
24、l or simultaneous spectrometer is suitable.7.6 Magnetic Stirring Bars, polytetrafluoroethylene (PTFE) coated, approximately 12 mm (12 in.) in length.7.7 Magnetic Stirring Hot Plate.TABLE 1 Elements Determined and Suggested WavelengthsElement Wavelengths, nmA ,B ConcentrationRange, mg/kgCAluminum 237
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD56002014STANDARDTESTMETHODFORTRACEMETALSINPETROLEUMCOKEBYINDUCTIVELYCOUPLEDPLASMAATOMICEMISSIONSPECTROMETRY40ICPAES41

链接地址:http://www.mydoc123.com/p-520211.html