ASTM D5280-1996(2013) Standard Practice for Evaluation of Performance Characteristics of Air Quality Measurement Methods with Linear Calibration Functions《使用线性校准功能评估空气质量测量方法的性能特性的标.pdf
《ASTM D5280-1996(2013) Standard Practice for Evaluation of Performance Characteristics of Air Quality Measurement Methods with Linear Calibration Functions《使用线性校准功能评估空气质量测量方法的性能特性的标.pdf》由会员分享,可在线阅读,更多相关《ASTM D5280-1996(2013) Standard Practice for Evaluation of Performance Characteristics of Air Quality Measurement Methods with Linear Calibration Functions《使用线性校准功能评估空气质量测量方法的性能特性的标.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5280 96 (Reapproved 2013)Standard Practice forEvaluation of Performance Characteristics of Air QualityMeasurement Methods with Linear Calibration Functions1This standard is issued under the fixed designation D5280; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice2covers procedures for evaluating thefollowing
3、performance characteristics of air quality measure-ment methods: bias (in part only), calibration function andlinearity, instability, lower detection limit, period of unattendedoperation, selectivity, sensitivity, and upper limit of measure-ment.1.2 The procedures presented in this practice are appl
4、icableonly to air quality measurement methods with linear continu-ous calibration functions, and the output variable of which is adefined time average. The linearity may be due to postprocess-ing of the primary output variable. Additionally, replicatevalues belonging to the same input state are assu
5、med to benormally distributed. Components required to transform theprimary measurement method output into the time averagesdesired are regarded as an integral part of this measurementmethod.1.3 For surveillance of measurement method stability underroutine measurement conditions, it may suffice to ch
6、eck theessential performance characteristics using simplified tests, thedegree of simplification acceptable being dependent on theknowledge on the invariance properties of the performancecharacteristics previously gained by the procedures presentedhere.1.4 There is no fundamental difference between
7、the instru-mental (automatic) and the manual (for example, wet-chemical) procedures, as long as the measured value is anaverage representative for a predefined time interval.Therefore, the procedures presented are applicable to both.Furthermore, they are applicable to measurement methods forambient,
8、 workplace, and indoor atmospheres, as well asemissions.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bilit
9、y of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1356 Terminology Relating to Sampling and Analysis ofAtmospheresE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminology Relating to Quality and Statistics2.2 ISO Standard:ISO 6879:
10、1983, Air QualityPerformance Characteristicsand Related Concepts for Air Quality Measuring Meth-ods43. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this practice, refer toTerminology D1356.3.2 Definitions of Terms Specific to This Standard:NOTE 1The statistical performance chara
11、cteristics used throughoutthis practice are estimated, by convention, at the confidence level1 = 0.95.3.2.1 averaging time predefined time interval length forwhich the air quality characteristic is made representative and the averaging time.3.2.1.1 DiscussionEvery measured value obtained is rep-rese
12、ntative for a defined interval of time, , the value of whichalways lies above a certain minimum due to the intrinsicproperties of the measuring procedure applied. In order toattain mutual comparability of data pertaining to comparableobjects, a normalization to a common, predefined interval oftime i
13、s necessary.1This practice is under the jurisdiction ofASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.03 on Ambient Atmospheresand Source Emissions.Current edition approved April 1, 2013. Published April 2013. Originallyapproved in 1994. Last previous edition a
14、pproved in 2007 as D5280 - 96(2007).DOI: 10.1520/D5280-96R13.2This practice was adapted from International Standard ISO/DP 9169, preparedby ISO/TC 146/SC 4/WG 4, by the kind permission of the Chairman of ISO/TC 146and the Secretariat of ISO/TC 146/SC 4.3For referenced ASTM standards, visit the ASTM
15、website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from International Organization for Standardization, Case Pastale 56,CH-1211, Geneva 20, Switzerl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD528019962013STANDARDPRACTICEFOREVALUATIONOFPERFORMANCECHARACTERISTICSOFAIRQUALITYMEASUREMENTMETHODSWITHLINEARCALIBRATIONFUNCTIONS

链接地址:http://www.mydoc123.com/p-519362.html