ASTM D4766-1998(2009)e1 Standard Test Method for Vinyl Chloride in Workplace Atmospheres (Charcoal Tube Method)《测定工作场所中氯乙烯的标准试验方法(活性碳法)》.pdf
《ASTM D4766-1998(2009)e1 Standard Test Method for Vinyl Chloride in Workplace Atmospheres (Charcoal Tube Method)《测定工作场所中氯乙烯的标准试验方法(活性碳法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4766-1998(2009)e1 Standard Test Method for Vinyl Chloride in Workplace Atmospheres (Charcoal Tube Method)《测定工作场所中氯乙烯的标准试验方法(活性碳法)》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4766 98 (Reapproved 2009)1Standard Test Method forVinyl Chloride in Workplace Atmospheres (Charcoal TubeMethod)1This standard is issued under the fixed designation D4766; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEReapproved with editorial changes in October 2009.1. Scope1.1 This test method describes the determination of v
3、inylchloride monomer (VCM) in workplace atmospheres using amodified charcoal tube method (see Practice D3686).1.2 This procedure is compatible with low flow rate per-sonal sampling equipment. It can be used for personal orstationary monitoring. It cannot determine instantaneous fluc-tuations in conc
4、entration to detect maximum values. Alterna-tive on-site procedures, such as gas chromatography or infraredspectrometry, must be used to measure fast-changing concen-trations.1.3 The range of this test method is from the limit ofdetection of approximately 0.01 to 100 ppm (v).1.4 The sampling method
5、provides a time-weighted averagesample.1.5 The values stated in SI units shall be regarded as thestandard. Inch-pound units are provided for information only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user
6、of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For more specificprecautionary statements, see Section 9 and Warnings in 10.2.3and 11.1.3.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relat
7、ing to Sampling and Analysis ofAtmospheresD3686 Practice for Sampling Atmospheres to Collect Or-ganic Compound Vapors (Activated Charcoal Tube Ad-sorption Method)E355 Practice for Gas Chromatography Terms and Rela-tionships3. Terminology3.1 DefinitionsFor definitions of terms relating to this testme
8、thod, refer to Terminology D1356 and Practice E355.4. Summary of Test Method4.1 Known volumes of sample air are passed through glassor metal tubes packed with activated charcoal. Vinyl chloride isadsorbed on the charcoal and thus removed from the flowinggas stream (1-3).34.2 A two-section tube conta
9、ining a front and a backupsection of adsorbent is used to collect the sample.4.3 The vinyl chloride is desorbed with carbon disulfide andanalyzed with a gas chromatograph equipped with a flameionization detector. Two or more different columns are to beused to reveal interferences that might otherwis
10、e not bedetected.4.4 Adsorption/desorption efficiencies are determined bythe same techniques used for the atmospheric analysis appliedto known standards. Instrument calibrations are made withprepared standard solutions of vinyl chloride in carbon disul-fide.5. Significance and Use5.1 Vinyl chloride
11、monomer (VCM) is the starting materialfor the manufacture of poly(vinyl chloride) (PVC), which isused extensively in construction, electronics, packaging, andother industries. The vinyl chloride gas can escape duringmanufacturing, transportation, and polymerization stages. Re-sidual monomer can also
12、 escape during subsequent fabricationprocesses.5.2 Vinyl chloride is a toxic and explosive hazardousmaterial.5.3 Vinyl chloride is suspected to be a carcinogenic agent(4), and occupational exposure limits (OELs) have beenestablished for this agent. For instance, the present U.S.1This test method is
13、under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.04 on Workplace AirQuality.Current edition approved Oct. 1, 2009. Published December 2009. Originallyapproved in 1988. Last previous edition approved in 2003 as D4766 98(03). DOI:10.1520/D
14、4766-98R09E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to t
15、he list of references at the end ofthis test method.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Occupational Safety and Health Administration (OSHA) stan-dard for VCM is 1.0 ppm (v) with a 0.5-ppm (v) action level;the maximum len
16、gth of operator exposure at 5 ppm (v) is 15min.45.4 The method is made selective for vinyl chloride bychoosing chromatograph columns that will separate vinylchloride from other organic compounds in the sample.5.5 The method meets requirements (for example, those ofOSHA) for monitoring workplace atmo
17、spheres in vinyl chlo-ride and poly(vinyl chloride) production and fabrication pro-cesses.6. Interferences6.1 Organic components that have the same or nearly thesame retention time as vinyl chloride during gas-chromatographic analysis will interfere.6.2 Other volatile organic compounds in the area s
18、amplesshould be given consideration.6.3 Such interferences can be minimized by proper selectionof gas-chromatographic columns. A mass spectrometric detec-tor can be used to confirm the presence of vinyl chloride.6.4 Water mists and high humidity affect adsorption effi-ciencies by reducing the adsorp
19、tive capacity of the charcoal forvinyl chloride.7. Apparatus7.1 Charcoal Sampling Tube:7.1.1 DescriptionA sampling tube consists of a length ofglass tubing containing two sections of activated charcoal thatare held in place by nonadsorbent material and sealed at eachend.7.1.2 Sampling tubes are comm
20、ercially available and con-sist of a glass tube 110 mm long, 10 mm in outside diameter,and 8 mm in inside diameter. They contain two sections of20/40 mesh activated charcoal, 800 and 200 mg, each separatedby a 2-mm section of urethane foam. The front section isretained by a plug of glass wool and th
21、e back section is retainedby a second 2-mm portion of urethane foam or other retainer,such as glass wool. The ends of the tube are flame sealed.7.1.3 The back section of the sample tube (200 mg) adsorbsvapors that penetrate the front section and is used to determinewhether the collection capacity of
22、 the tube has been exceeded.Instead of a single tube, two tubes in series may be used (see11.1.11).7.1.4 The pressure drop across the charcoal tube should beno greater than 2.5 cm Hg 3.3 kPa at a flowrate of 1000mL/min.7.1.5 Glass tubes must be held in suitable protective holdersto prevent breakage
23、during sampling.7.2 Syringes:7.2.1 Gas-Tight Syringe, 1 to 2-mL capacity.7.2.2 Microlitre Syringes, 10, 25, and 100-L or otherconvenient sizes for making standards.7.3 Polyethylene End Caps, for capping charcoal tube. Capsmust fit snugly to prevent leakage.7.4 Vials, glass, approximately 12 mL (3-dr
24、am), for desorb-ing samples and holding standards, polyethylene or TFE-fluorocarbon-lined screw cap or septum valve.A1-oz. vial withthe same types of closure is needed for standard preparation.7.5 Plastic BagsPoly(vinylidine chloride) or poly(vinylfluoride), 50 to 100 L, for preparing known concentr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD476619982009E1STANDARDTESTMETHODFORVINYLCHLORIDEINWORKPLACEATMOSPHERESCHARCOALTUBEMETHOD 测定 工作 场所

链接地址:http://www.mydoc123.com/p-517926.html