《ASTM D4251-1989(2016) Standard Test Method for Active Matter in Anionic Surfactants by Potentiometric Titration《采用电位滴定法测定阴离子表面活性剂中活性物质的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4251-1989(2016) Standard Test Method for Active Matter in Anionic Surfactants by Potentiometric Titration《采用电位滴定法测定阴离子表面活性剂中活性物质的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4251 89 (Reapproved 2016)Standard Test Method forActive Matter in Anionic Surfactants by PotentiometricTitration1This standard is issued under the fixed designation D4251; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a potentiometric titrationprocedure for determining the anionic active matte
3、r in deter-gents. It is intended for the analysis of anionic surfactants suchas detergent range alkylbenzenesulfonates, -olefin sulfonates,alcohol sulfates, and alcohol ethosulfates. It has not been testedfor surfactant formulations.1.2 The values stated in SI units are to be regarded asstandard. No
4、 other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bili
5、ty of regulatory limitations prior to use. Material SafetyData Sheets are available for reagents and materials. Reviewthem for hazards prior to usage.2. Referenced Documents2.1 ASTM Standards:2D459 Terminology Relating to Soaps and Other DetergentsD1193 Specification for Reagent WaterD1681 Test Meth
6、od for Synthetic Anionic Active Ingredientin Detergents by Cationic Titration ProcedureD3049 Test Method for Synthetic Anionic Ingredient byCationic TitrationE180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals (Withdrawn 2009)33.
7、 Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 active matterthe organic surface-active materialpresent in the detergent and defined in Terminology D459 asactive ingredient of a synthetic detergent.4. Summary of Test Method4.1 A detergent sample containing active matter is titra
8、tedpotentiometrically in an aqueous medium with a standardsolution of Hyamine 1622 using a nitrate ion-selective elec-trode. The titration reaction involves the formation of acomplex between the cationic quaternary ammonium titrant(Hyamine 1622) and the anionic surfactant which precipitates.The nitr
9、ate electrode probably responds to the concentration ofunreacted anionic surfactant.5. Significance and Use5.1 Anionic surfactants are the most widely used of thesynthetic detergents. ASTM methods in current use for theirdetermination involve two-phase aqueous/chloroform titrationswith the organic d
10、yes methylene blue (Test Method D1681)ordisulphine blue/dimidium bromide (Test Method D3049)asindicators. One advantage of the potentiometric method is thatit eliminates the use of chloroform whose use is restricted forenvironmental and toxicological reasons.5.2 This test method is intended for use
11、as described in 1.1.6. Apparatus6.1 Potentiometric Titration Assembly, consisting of anautomatic titrator (Metrohm E536 or equivalent) fitted with anitrate ion-selective electrode (Orion Model 93-07 Nitrate ISE,or equivalent) and a Ag/AgCl reference electrode (MetrohmEA 440 or equivalent) together w
12、ith a buret assembly having a5-mL buret (Metrohm E575) and 150-mL beaker. A TFE-fluorocarbon star-head stirring bar can be used to providemixing and eliminate foaming during titration. Use of theOrion electrode with a Metrohm E536 requires an adapter(Metrohm EA-1046/2).NOTE 1The conditioning of the
13、electrode is essential for obtaining agood break in the titration curve. Conditioning new electrodes in 0.01 MNaNO3aqueous solution for 60 min (or more) prior to use is recom-mended. Condition previously used electrodes by using again for the1This test method is under the jurisdiction of ASTM Commit
14、tee D12 on Soapsand Other Detergents and is the direct responsibility of Subcommittee D12.12 onAnalysis and Specifications of Soaps, Synthetics, Detergents and their Components.Current edition approved July 1, 2016. Published August 2016. Originallyapproved in 1983. Last previous edition approved in
15、 2009 as D4251 89(2009).DOI: 10.1520/D4251-89R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last ap
16、proved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1titration of aqueous sodium lauryl sulfate with Hyamine.NOTE 2Other electrodes (for example a calomel electrode) a
17、resuitable as the reference electrode provided they give a stable referencepotential during the titration. Reference electrodes having a ceramic or anasbestos junction tend to clog with use. Therefore, a ground-glass sleeveelectrode (such as the Metrohm EA 440) is suggested.7. Reagents7.1 Hyamine 16
18、22, diisobutylphenoxyethoxyethyl dimethylbenzyl ammonium chloride.7.2 Sodium Lauryl Sulfate, primary standard (Note 3).NOTE 3Sodium lauryl sulfate must be analyzed for purity accordingto the Reagent section of Test Method D3049, before using as a primarystandard.7.3 Water, type III reagent water con
19、forming to Specifica-tion D1193.8. Preparation of Standard Reagents8.1 Sodium Lauryl Sulfate Solution, 4102NWeighaccurately 11.5 6 0.5 g of sodium lauryl sulfate to 0.1 mg;dissolve in water and dilute to a final volume of 1 L. Calculatethe normality of the solution with the following equation:Normal
20、ity of sodium lauryl sulfate 5W!P!288.38!100!(1)where:P = purity of the sodium lauryl sulfate, weight %, andW = weight of sodium lauryl sulfate, g.8.1.1 Keep the solution no longer than 1 month beforemaking a fresh solution.8.2 Hyamine 1622 Solution, 4102NDissolve 18 6 0.5g of Hyamine 1622 in deioni
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD425119892016STANDARDTESTMETHODFORACTIVEMATTERINANIONICSURFACTANTSBYPOTENTIOMETRICTITRATION 采用 电位

链接地址:http://www.mydoc123.com/p-516634.html