《ASTM D4243-1999(2004)e1 Standard Test Method for Measurement of Average Viscometric Degree of Polymerization of New and Aged Electrical Papers and Boards《新的和老化的电绝缘纸和纸板聚合作用的平均粘滞程度的测.pdf》由会员分享,可在线阅读,更多相关《ASTM D4243-1999(2004)e1 Standard Test Method for Measurement of Average Viscometric Degree of Polymerization of New and Aged Electrical Papers and Boards《新的和老化的电绝缘纸和纸板聚合作用的平均粘滞程度的测.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4243 99 (Reapproved 2004)e1An American National StandardStandard Test Method forMeasurement of Average Viscometric Degree ofPolymerization of New and Aged Electrical Papers andBoards1This standard is issued under the fixed designation D 4243; the number immediately following the desig
2、nation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEReferences to IEC 450 were replaced
3、with IEC 60450 in 2.2 and 4.2 editorially in December 2004.1. Scope1.1 This test method describes a standard procedure fordetermining the average viscometric degree of polymerization(abbreviated DPv) of new or aged electrical papers. Thedetermination is made by measuring the intrinsic viscosity of a
4、solution of the paper in an appropriate solvent.1.2 The degree of polymerization (or the degree of conden-sation) of a particular cellulose molecule is the number ofanhydro-b-glucose monomers, C6H10O5, in the cellulose mol-ecule. Within a sample of paper, not all the cellulose moleculeshave the same
5、 degree of polymerization so that the mean valuemeasured by viscometric methods is not necessarily the sameas that which may be obtained by other methods.1.3 This standard may involve hazardous materials, opera-tions, and equipment. This standard does not purport toaddress all of the safety concerns
6、, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and todetermine the applicability of regulatory limitations prior touse. See Section 92. Referenced Documents2.1 ASTM Standards:2D 445 Test Method for Kinematic
7、 Viscosity of Transparentand Opaque Liquids (and the Calculation of DynamicViscosity)D 1711 Terminology Relating to Electrical Insulation2.2 Other Document:IEC Publication 60450 Measurement of the Average Visco-metric Degree of Polymerization of New and AgedElectrical Papers33. Terminology3.1 Defini
8、tionsFor definitions of terms used in this testmethod, refer to Terminology D 1711.4. Summary of Test Method4.1 This test method measures the specific viscosity of asolution of the paper in cupriethylenediamine. From thismeasurement the intrinsic viscosity of the solution is deduced,and from this th
9、e degree of polymerization is easily calculated.4.2 This test method follows very closely the proceduresspecified in IEC 60450.5. Significance and Use5.1 This test method may be applied to all papers made fromunmodified cellulose, as used in transformer, cable, or capaci-tor manufacture. It applies
10、to new or aged papers. Forinformation, Appendix X2 shows an example of statisticaldistribution of DPvvalues for new papers intended for theinsulation of transformers, together with information relative tocable and capacitor papers. Nevertheless, where evaluating thedecomposition stage of aged papers
11、, take care to use, as areference, the DPvvalue of the new paper of the very sameorigin; DPvof new papers being a function, among otherfactors, of their specific gravity and of their manufacturingprocess.5.2 This test method can also be used for the determinationof the intrinsic viscosity of solutio
12、ns of chemically modifiedpapers, provided that these dissolve completely in the selectionsolvent. This test method should be used with caution when itis applied to papers with mineral fillers.1This test method is under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Mat
13、erials and is the direct responsibility ofSubcommittee D09.19 on Dielectric Sheet and Roll Products.Current edition approved April 10, 1999. Published June 1999. Originallyapproved in 1983. Last previous edition approved in 1998 as D 4243 86 (1998).2For referenced ASTM standards, visit the ASTM webs
14、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute, 11 W. 42nd St., 13thFloor, New York, NY 10036.1Copyright
15、ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Interferences6.1 Lignins, that are present in measurable amounts in mostpapers and boards, may have an effect on the test results,depending upon concentration and composition. For this rea-son,
16、 it is important in aging studies to use as a referencesamples of the unaged paper as mentioned in 5.1.6.2 Under some conditions of heat and atmosphere, crosslinking of cellulose molecules may occur, resulting in erratictest values. This effect has been observed for capacitor tissue invacuum at temp
17、eratures as low as 110 C and for other papersaged in air at higher temperatures.7. Apparatus7.1 Apparatus for Solution:7.1.1 Round-Bottomed 50-mL Flask, preferably with a shortnarrow neck, or a narrow-necked 50-mL Erlenmeyer flask.7.1.2 Rubber Stopper, fitting the neck of the flask, throughwhich pas
18、ses a capillary tube fitted with a small-bore cockglass cock; or a ground stopper, fitted with a small-bore cockmay be used with a ground-neck flask.7.1.3 Glass Balls, 4 to 6-mm diameter, that shall not be ableto enter the bore of the cock.7.1.4 Mechanical Stirrer, to rotate the solution flask with
19、auniform circular motion with a horizontal axis between 20 and40 r/min. The flask shall be mounted so that its axis is normalto the axis of rotation, and the radius of gyration shall not begreater than 200 mm.7.2 Apparatus for Measurement of Viscosity:7.2.1 Apparatus for Measurement of Kinematic Vis
20、cosity,asdescribed in Test Method D 445. The viscometer shall have acalibration constant, C, of from 0.00010 or 0.00013 St/s (10 3109to 13 3 109m2/s2).7.2.2 This constant shall be determined by measuring theefflux-time T (seconds) of a liquid of known dynamic viscosity(Ns/m2) and density r (g/cm3).
21、It is given by the formula:C 5hr T(1)7.2.3 Constant-Temperature Water Bath, regulated at 20 60.1 C.7.2.4 Stopwatch, with an accuracy of 0.1 s.7.3 Apparatus for Measurement of Water Content of PaperSample:7.3.1 Weighing Containers, impermeable to water vapor,with airtight lids.7.3.2 Ventilated Drying
22、 Oven, thermostatically controlled at105 6 2 C.7.3.3 Desiccator.8. Reagents8.1 Cupriethylene-Diamine Solution:8.1.1 The formula ascribed to cupriethylene-diamine (CED)is:CuNH22 CH22 CH2NH2!2#OH!2(2)This implies a molar ratio of 2 between the concentration ofethylene-diamine and the concentration of
23、copper:CED/Ccu! 5 2 (3)8.1.2 Cupriethylene-diamine solution may be purchasedcommercially at several different concentrations. At a concen-tration greater than 1 M it may be kept for one year in the dark.It is diluted to 1 M when required for use. Alternatively theCED solution can be made in the labo
24、ratory at its workingstrength of 1 M by the methods described in Annex A1.8.1.3 The 1 M solution will keep only for a limited time. Asoften as necessary the solution should be checked by:8.1.3.1 Using the method described in Annex A2 to verifythat the ratioCED/CCu5 2.0 6 0.1. (4)8.1.3.2 Verify that
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD424319992004E1STANDARDTESTMETHODFORMEASUREMENTOFAVERAGEVISCOMETRICDEGREEOFPOLYMERIZATIONOFNEWANDAGEDELECTRICALPAPERSANDBOARDS

链接地址:http://www.mydoc123.com/p-516623.html