ASTM D4148-1982(2004) Standard Test Method for Analysis of Phytoplankton in Surface Water by the Sedgwick-Rafter Method《用Sedgwick-木筏法分析地表水中可繁殖浮游生物的标准试验方法》.pdf
《ASTM D4148-1982(2004) Standard Test Method for Analysis of Phytoplankton in Surface Water by the Sedgwick-Rafter Method《用Sedgwick-木筏法分析地表水中可繁殖浮游生物的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4148-1982(2004) Standard Test Method for Analysis of Phytoplankton in Surface Water by the Sedgwick-Rafter Method《用Sedgwick-木筏法分析地表水中可繁殖浮游生物的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4148 82 (Reapproved 2004)Standard Test Method forAnalysis of Phytoplankton in Surface Water by theSedgwick-Rafter Method1This standard is issued under the fixed designation D 4148; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers determining the density andtaxonomic classification of phytoplankton
3、. It is applicable bothto relatively sparse or dense phytoplankton concentrations,provided the suspended-sediment concentration is low. TheSedgwick Rafter (S-R) method requires less costly apparatusthan does the inverted microscope method but gives lessaccurate results. The inherent inaccuracy in th
4、e Sedgwick-Rafter method is due to the design of the counting chamber andcannot be circumvented by a different choice of optics. For thisreason, the S-R method is limited to the use of objective lenseshaving a working distance of approximately 1.6 mm or more.With 103 oculars the maximum overall magn
5、ification isapproximately 2503. High concentrations of suspended sedi-ment can obscure the algal cells, and thus cause interference.1.2 This test method is applicable to both freshwater andmarine samples.1.3 This standard does not purport to address all of thesafety problems, if any, associated with
6、 its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary information see Section 8.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminol
7、ogy Relating to WaterD 1193 Specification for Reagent WaterD 3370 Practices for Sampling WaterD 4149 Classification for Sampling Phytoplankton in Sur-face Waters2.2 Various taxonomic keys are required for identificationof the algae. No single key is suitable for all species likely tobe encountered.
8、(See Greeson 1977; Weber 1973.)3. Summary of Test Method3.1 The microscope is calibrated to determine the field sizeon the superimposed ocular grid. A Sedgwick-Rafter chamberis filled with a preserved phytoplankton sample. After the algaesettles to the bottom, the chamber is examined microscopically
9、at 200 to 2503 for the presence of algae. Those algal cellslying within the border of the ocular grid are identified andenumerated. The tally is used to calculate the algal density incells per millilitre.4. Significance and Use4.1 Phytoplankton are basic to the food chain in all aquaticenvironments.
10、 In addition, they have long been considered tobe important indicators of water-quality conditions. Phy-toplankton data are also frequently used in the planning anddesign of water-treatment facilities and reservoirs.5. Interferences5.1 The presence of suspended sediment may obscure algalcells, makin
11、g identification difficult. Colonial forms and theoccurrence of algae in trichomes make the estimation of cellnumbers difficult. Some preservation techniques may cause aloss of flagella, hampering identification.6. Apparatus6.1 Microscope, compound, with 103 oculars and 103,253,403, and 903 objectiv
12、es, substage condenser, andmechanical stage.6.2 Ocular Micrometer, with Whipple grid.6.3 Sedgwick-Rafter Counting Cell,50by20by1mm.6.4 Stage Micrometer.6.5 Transfer Pipet, 1-mL.6.6 Microscope Slides and Cover Glasses, standard 76 by25-mm noncorrosive slides. Cover glasses, round or square,clean and
13、free of oil.7. Reagents7.1 Purity of ReagentReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,1This test method is under the juri
14、sdiction of ASTM Committee E47 onBiological Effects and Environmental Fate and is the direct responsibility ofSubcommittee E47.01 on Aquatic Assessment and Toxicology.Current edition approved April 1, 2004. Published April 2004. Originallyapproved in 1982. Last previous edition approved in 1998 as D
15、 4148 82 (1998).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbo
16、r Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.7.2 Purity of W
17、aterUnless otherwise indicated, referencesto water shall be understood to mean Type I reagent waterconforming to Specification D 1193.7.3 FormalinTo prepare the formalin preservative, mix900 mL of 37 to 40 % aqueous formaldehyde (100 % formalin)with 100 to 150 mL of 20 % surgical detergent solution
18、and 20to 30 mL of saturated cupric sulfate solution.7.4 Lugols SolutionAn alternative preservative isLugols solution. Prepare a stock Lugols solution by dissolv-ing 600 g of potassium iodide and 40 g of iodine crystals in1000 mL of water.8. Precautions8.1 Formaldehyde vapors are toxic, and the conce
19、ntratedsolution can damage exposed skin or eyes. Wear waterproofgloves and appropriate eye protection when handling concen-trated formaldehyde solutions. Work in adequately ventilatedareas.9. Sampling9.1 Collect the sample in accordance with ClassificationD 4149.9.2 Preserve the sample with either f
20、ormalin or Lugolssolution. If formalin preservative is desired, mix 40 to 50 mLof formalin preservative with each 1000 mL of sample. IfLugols solution is preferred, mix 37 mL of Lugols solutionwith each 1000 mL of sample, and store in the dark.10. Microscope Calibration10.1 Mount the ocular micromet
21、er (Whipple grid) in oneeyepiece in accordance with the manufacturers instructions forplacement.10.2 Set up the microscope and place the stage micrometeron the stage with the etched markings upper most.10.3 Focus on the ruled graduations under low power(1003). Measure and record the dimensions of th
22、e Whipplegrid to the nearest 0.01 mm. Repeat the procedure for all otherobjective/ocular combinations suitable for use with theSedgwick-Rafter cell. Often this is 2003 or 2503. At magni-fications greater than 1003, the Whipple grid should bemeasured to the nearest 0.001 mm (American Public HealthAss
23、ociation, 1976). Calculate and record the area enclosed bythe Whipple grid in square millimetres at each magnification.11. Pretreatment11.1 Some samples may require concentration or dilutionprior to analysis. The decision to concentrate or dilute issubjective and should be reached only after microsc
24、opicexamination of the sample. This can be done by preparing awet mount as follows: Mix the sample gently, then pipet a droponto a clean microscope slide, and add a cover slip. Examineat 1003 for general concentration. If desired, concentration ordilution may be performed by one of the following pro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD414819822004STANDARDTESTMETHODFORANALYSISOFPHYTOPLANKTONINSURFACEWATERBYTHESEDGWICKRAFTERMETHOD

链接地址:http://www.mydoc123.com/p-516388.html