《ASTM D4016-2008 Standard Test Method for Viscosity of Chemical Grouts by Brookfield Viscometer (Laboratory Method)《用BROOKFIELD粒度计测定化学灌浆粘度的试验方法(实验室法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4016-2008 Standard Test Method for Viscosity of Chemical Grouts by Brookfield Viscometer (Laboratory Method)《用BROOKFIELD粒度计测定化学灌浆粘度的试验方法(实验室法)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4016 08Standard Test Method forViscosity of Chemical Grouts by Brookfield Viscometer(Laboratory Method)1This standard is issued under the fixed designation D 4016; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of viscosityof catalysed chemical grouts with the Brookfield visco
3、meter(laboratory method), over the range from 1.0 to 1000 cP (0.001to 1 Pas).1.2 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determ
4、ine the applica-bility of regulatory limitations prior to use.1.3 This test method offers a set of instructions for perform-ing one or more specific operations. This document cannotreplace education or experience and should be used in con-junction with professional judgment. Not all aspects of thisp
5、ractice may be applicable in all circumstances. This ASTMstandard is not intended to represent or replace the standard ofcare by which the adequacy of a given professional servicemust be judged, nor should this document be applied withoutconsideration of a projects many unique aspects. The word“Stan
6、dard” in the title of this document means only that thedocument has been approved through the ASTM consensusprocess.2. Referenced Documents2.1 ASTM Standards:2D 653 Terminology Relating to Soil, Rock, and ContainedFluidsD 3740 Practice for Minimum Requirements for AgenciesEngaged in the Testing and/
7、or Inspection of Soil and Rockas Used in Engineering Design and ConstructionD 6026 Practice for Using Significant Digits in Geotechni-cal DataE1 Specification for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 For common definitions of terms used in this standard,refer to Terminology D 653.3.2 D
8、efinitions of Terms Specific to This Standard:3.2.1 coeffcient of viscositythe ratio between the appliedshear stress and the rate of shear. This coefficient is a measureof the resistance to flow of the liquid. It is commonly called theviscosity of the liquid. The cgs unit of viscosity is 1 g/cms (1d
9、yn/s cm2) and is called a poise (P). Viscosities of thin liquidsare normally given in hundredths of a poise or centipoises (cP).The SI unit of viscosity is 1 Pas (1 Ns/m2) and is equal to 10P, or 1000 cP.3.2.2 Newtonian liquida liquid in which the shear stress isproportional to the rate of shearing
10、strain. This constant ratio isthe viscosity. Non-Newtonian behavior can be determined withthe Brookfield instrument by taking measurements at differentspindle speeds.4. Summary of Test Method4.1 A rotating spindle is immersed in a container of cataly-sed chemical grout.An index to the viscosity is r
11、ead directly onthe instrument scale.5. Significance and Use5.1 This test is intended for materials that will penetrate soilvoids and rock fissures. Viscosity alone is not necessarily anexact index of grout penetrability.NOTE 1The quality of the result produced by this test method isdependent on the
12、competence of the personnel performing it and thesuitability of the equipment and facilities used. Agencies that meet thecriteria of Practice D 3740 are generally considered capable of competentand objective testing/sampling/inspection/etc. Users of this standard arecautioned that compliance with of
13、 Practice D 3740 does not in itself assurereliable results. Reliable results depend on mnay factors; of PracticeD 3740 provides a means of evaluating some of those factors.6. Apparatus6.1 Brookfield ViscometerAny model whose lower limitof effective measurement is less than the value of the sample.Mo
14、dels LVF and LVT should be used for measurements above20 cP (20 mPas), and for measurements from 1 to 20 cP (1 to1This test method is under the jurisdiction ofASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.15 on Stabilization WithAdmixtures.Current edition ap
15、proved Jan. 1, 2008. Published February 2008. Originallyapproved in 1981. Last previous edition approved in 2002 as D 4016 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,
16、 refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.20 mPas) with the addition of a Model ULadapter. Model
17、s RV,RT, HA, and HB may be used for measurements above 100 cP(100 mPas).NOTE 2The UL adapter may be used for better accuracy in the 20 to100-cP (20 to 100-mPas) range also.6.2 Griffn Beaker, 600-cm3, low-form used as the containerfor the sample. Beaker material must not react with the grout.Glass be
18、akers are not acceptable for silicates. Stainless steelbeakers are acceptable for all materials.6.3 Calibrated Liquid-in-Glass Thermometers, accurate to61.0F (0.5C), or any other thermometric device of equalaccuracy.NOTE 3Glass thermometers should not be used with silicates.6.4 Temperature-Control B
19、ath, for work at other than am-bient temperature, and large enough to hold the samplecontainer. Any bath that will maintain its temperature within61.0F (0.5C) during the test period is adequate.NOTE 4Grout temperature must equal bath temperature at the start ofthe test. Temperature rise due to chemi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD40162008STANDARDTESTMETHODFORVISCOSITYOFCHEMICALGROUTSBYBROOKFIELDVISCOMETERLABORATORYMETHOD BROOKFIELD

链接地址:http://www.mydoc123.com/p-516066.html