ASTM D3359-2009e1 Standard Test Methods for Measuring Adhesion by Tape Test.pdf
《ASTM D3359-2009e1 Standard Test Methods for Measuring Adhesion by Tape Test.pdf》由会员分享,可在线阅读,更多相关《ASTM D3359-2009e1 Standard Test Methods for Measuring Adhesion by Tape Test.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3359 091Standard Test Methods forMeasuring Adhesion by Tape Test1This standard is issued under the fixed designation D3359; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1NOTEFootnote 5 and 5.2 were corrected editorially in June 2010.1. Scope*1.1 These
3、 test methods cover procedures for assessing theadhesion of coating films to metallic substrates by applying andremoving pressure-sensitive tape over cuts made in the film.NOTE 1This test method has been reported being used to measureadhesion of organic coatings on soft substrates (for example, wood
4、 andplastic). Issues with plastic substrates are noted inAppendix X1.Asimilartest method, ISO 2409, permits tests on soft substrates (for example, woodand plaster). Precision and bias data on the later is lacking. Test MethodsD3359 was developed with metal as the substrate and, in the absence ofsupp
5、orting precision and bias data, is so limited.1.2 Test Method A is primarily intended for use at job siteswhile Test Method B is more suitable for use in the laboratory.Also, Test Method B is not considered suitable for films thickerthan 5 mils (125m).NOTE 2Subject to agreement between the purchaser
6、 and the seller,Test Method B can be used for thicker films if wider spaced cuts areemployed.1.3 These test methods are used to establish whether theadhesion of a coating to a substrate is at a generally adequatelevel. They do not distinguish between higher levels ofadhesion for which more sophistic
7、ated methods of measure-ment are required.NOTE 3It should be recognized that differences in adherability of thecoating surface can affect the results obtained with coatings having thesame inherent adhesion.1.4 This test method is similar in content (but not techni-cally equivalent) to ISO 2409.1.5 I
8、n multicoat systems adhesion failure may occur be-tween coats so that the adhesion of the coating system to thesubstrate is not determined.1.6 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.7 This standard does not purport t
9、o address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D609 Practice for P
10、reparation of Cold-Rolled Steel Panelsfor Testing Paint, Varnish, Conversion Coatings, andRelated Coating ProductsD823 Practices for Producing Films of Uniform Thicknessof Paint, Varnish, and Related Products on Test PanelsD1000 Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Elec
11、trical and Electronic Applica-tionsD1730 Practices for Preparation of Aluminum andAluminum-Alloy Surfaces for PaintingD2092 Guide for Preparation of Zinc-Coated (Galvanized)Steel Surfaces for Painting3D2370 Test Method for Tensile Properties of Organic Coat-ingsD3330/D3330M Test Method for Peel Adhe
12、sion ofPressure-Sensitive TapeD3924 Specification for Environment for Conditioning andTesting Paint, Varnish, Lacquer, and Related MaterialsD4060 Test Method for Abrasion Resistance of OrganicCoatings by the Taber Abraser1These test methods are under the jurisdiction of ASTM Committee D01 onPaint an
13、d Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.23 on Physical Properties of Applied PaintFilms.Current edition approved June 1, 2009. Published June 2009. Originallyapproved in 1974. Last previous edition approved in 2008 as D3359 08. DOI:10.1520
14、/D3359-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this histo
15、rical standard is referencedon www.astm.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.2 Other Standard:ISO 2409 Paint and Varnishes Cross-cut test43. Summary o
16、f Test Methods3.1 Test Method AAn X-cut is made through the film tothe substrate, pressure-sensitive tape is applied over the cut andthen removed, and adhesion is assessed qualitatively on the 0to 5 scale.3.2 Test Method BA lattice pattern with either six oreleven cuts in each direction is made in t
17、he film to thesubstrate, pressure-sensitive tape is applied over the lattice andthen removed, and adhesion is evaluated by comparison withdescriptions and illustrations.4. Significance and Use4.1 If a coating is to fulfill its function of protecting ordecorating a substrate, it must adhere to it for
18、 the expectedservice life. Because the substrate and its surface preparation(or lack of it) have a drastic effect on the adhesion of coatings,a method to evaluate adhesion of a coating to differentsubstrates or surface treatments, or of different coatings to thesame substrate and treatment, is of co
19、nsiderable usefulness inthe industry.4.2 The limitations of all adhesion methods and the specificlimitation of this test method to lower levels of adhesion (see1.3) should be recognized before using it. The intra- andinter-laboratory precision of this test method is similar to otherwidely-accepted t
20、ests for coated substrates (for example, TestMethod D2370 and Test Method D4060), but this is partly theresult of it being insensitive to all but large differences inadhesion. The limited scale of 0 to 5 was selected deliberatelyto avoid a false impression of being sensitive.TEST METHOD AX-CUT TAPE
21、TEST5. Apparatus and Materials5.1 Cutting ToolSharp razor blade, scalpel, knife or othercutting devices. It is of particular importance that the cuttingedges be in good condition.5.2 Cutting GuideSteel or other hard metal straightedgeto ensure straight cuts.NOTE 4Tapes put on the market at this time
22、 have a shelf life that runsout in July 2010. Subcommittee D01.23 is assessing alternative tapes anda new interlaboratory study is planned to take place in 2010. Alternativetapes with specifications similar to that of Permacel P99 tape are available.Users of alternative tapes should check whether th
23、e alternative tapes givecomparable results to the Permacel P99 tape.5.3 Tape25-mm (1.0-in.) wide semitransparent pressure-sensitive tape5with an adhesion strength agreed upon by thesupplier and the user is needed. Because of the variability inadhesion strength from batch-to-batch and with time, it i
24、sessential that tape from the same batch be used when tests areto be run in different laboratories. If this is not possible the testmethod should be used only for ranking a series of testcoatings.5.4 Rubber Eraser, on the end of a pencil.5.5 IlluminationA light source is helpful in determiningwhethe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD33592009E1STANDARDTESTMETHODSFORMEASURINGADHESIONBYTAPETESTPDF

链接地址:http://www.mydoc123.com/p-514650.html