ASTM D3359-2002 Standard Test Methods for Measuring Adhesion by Tape Test《胶带试验用测定粘合性的标准试验方法》.pdf
《ASTM D3359-2002 Standard Test Methods for Measuring Adhesion by Tape Test《胶带试验用测定粘合性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3359-2002 Standard Test Methods for Measuring Adhesion by Tape Test《胶带试验用测定粘合性的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3359 02Standard Test Methods forMeasuring Adhesion by Tape Test1This standard is issued under the fixed designation D 3359; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in paren
2、theses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover procedures for assessing theadhesion of coa
3、ting films to metallic substrates by applying andremoving pressure-sensitive tape over cuts made in the film.1.2 Test Method A is primarily intended for use at job siteswhile Test Method B is more suitable for use in the laboratory.Also, Test Method B is not considered suitable for films thickerthan
4、 5 mils (125m).NOTE 1Subject to agreement between the purchaser and the seller,Test Method B can be used for thicker films if wider spaced cuts areemployed.1.3 These test methods are used to establish whether theadhesion of a coating to a substrate is at a generally adequatelevel. They do not distin
5、guish between higher levels ofadhesion for which more sophisticated methods of measure-ment are required.NOTE 2It should be recognized that differences in adherability of thecoating surface can affect the results obtained with coatings having thesame inherent adhesion.1.4 In multicoat systems adhesi
6、on failure may occur be-tween coats so that the adhesion of the coating system to thesubstrate is not determined.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address the safetyconcer
7、ns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 609 Practice for Preparation of Cold-Rolled
8、Steel Panelsfor Testing Paint, Varnish, Conversion Coatings, andRelated Coating Products2D 823 Practices for Producing Films of Uniform Thicknessof Paint, Varnish, and Related Products on Test Panels2D 1000 Test Method For Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic A
9、pplica-tions3D 1730 Practices for Preparation of Aluminum andAluminum-Alloy Surfaces for Painting4D 2092 Guide for Preparation of Zinc-Coated (Galvanized)Steel Surfaces for Painting5D 2370 Test Method for Tensile Properties of OrganicCoatings2D 3330 Test Method for Peel Adhesion of Pressure-Sensitiv
10、e Tape6D 3924 Specification for Standard Environment for Condi-tioning and Testing Paint, Varnish, Lacquer, and RelatedMaterials2D 4060 Test Method for Abrasion Resistance of OrganicCoatings by the Taber Abraser23. Summary of Test Methods3.1 Test Method AAn X-cut is made through the film tothe subst
11、rate, pressure-sensitive tape is applied over the cut andthen removed, and adhesion is assessed qualitatively on the 0to 5 scale.3.2 Test Method BA lattice pattern with either six oreleven cuts in each direction is made in the film to thesubstrate, pressure-sensitive tape is applied over the lattice
12、 andthen removed, and adhesion is evaluated by comparison withdescriptions and illustrations.4. Significance and Use4.1 If a coating is to fulfill its function of protecting ordecorating a substrate, it must adhere to it for the expectedservice life. Because the substrate and its surface preparation
13、(or lack of it) have a drastic effect on the adhesion of coatings,a method to evaluate adhesion of a coating to differentsubstrates or surface treatments, or of different coatings to the1These test methods are under the jurisdiction of ASTM Committee D01 onPaint and Related Coatings, Materials, and
14、Applications and are the directresponsibility of Subcommittee D01.23 on Physical Properties of Applied PaintFilms.Current edition approved Aug. 10, 2002. Published October 2002. Originallypublished as D 3359 74. Last previous edition D 3359 97.2Annual Book of ASTM Standards, Vol 06.01.3Annual Book o
15、f ASTM Standards, Vol 10.01.4Annual Book of ASTM Standards, Vol 02.05.5Annual Book of ASTM Standards, Vol 06.02.6Annual Book of ASTM Standards, Vol 15.09.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.same substrate and treatment, i
16、s of considerable usefulness inthe industry.4.2 The limitations of all adhesion methods and the specificlimitation of this test method to lower levels of adhesion (see1.3) should be recognized before using it. The intra- andinter-laboratory precision of this test method is similar to otherwidely-acc
17、epted tests for coated substrates (for example, TestMethod D 2370 and Test Method D 4060), but this is partly theresult of it being insensitive to all but large differences inadhesion. The limited scale of 0 to 5 was selected deliberatelyto avoid a false impression of being sensitive.TEST METHOD AX-
18、CUT TAPE TEST5. Apparatus and Materials5.1 Cutting ToolSharp razor blade, scalpel, knife or othercutting devices. It is of particular importance that the cuttingedges be in good condition.5.2 Cutting GuideSteel or other hard metal straightedgeto ensure straight cuts.5.3 Tape25-mm (1.0-in.) wide semi
19、transparent pressure-sensitive tape7with an adhesion strength agreed upon by thesupplier and the user is needed. Because of the variability inadhesion strength from batch-to-batch and with time, it isessential that tape from the same batch be used when tests areto be run in different laboratories. I
20、f this is not possible the testmethod should be used only for ranking a series of testcoatings.5.4 Rubber Eraser, on the end of a pencil.5.5 IlluminationA light source is helpful in determiningwhether the cuts have been made through the film to thesubstrate.6. Test Specimens6.1 When this test method
21、 is used in the field, the specimenis the coated structure or article on which the adhesion is to beevaluated.6.2 For laboratory use apply the materials to be tested topanels of the composition and surface conditions on which it isdesired to determine the adhesion.NOTE 3Applicable test panel descrip
22、tion and surface preparationmethods are given in Practice D 609 and Practices D 1730 and D 2092.NOTE 4Coatings should be applied in accordance with PracticeD 823, or as agreed upon between the purchaser and the seller.NOTE 5If desired or specified, the coated test panels may be subjectedto a prelimi
23、nary exposure such as water immersion, salt spray, or highhumidity before conducting the tape test. The conditions and time ofexposure will be governed by ultimate coating use or shall be agreed uponbetween the purchaser and seller.7. Procedure7.1 Select an area free of blemishes and minor surfaceim
24、perfections. For tests in the field, ensure that the surface isclean and dry. Extremes in temperature or relative humiditymay affect the adhesion of the tape or the coating.7.1.1 For specimens which have been immersed: Afterimmersion, clean and wipe the surface with an appropriatesolvent which will
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD33592002STANDARDTESTMETHODSFORMEASURINGADHESIONBYTAPETEST 胶带 试验 测定 粘合 标准 方法 PDF

链接地址:http://www.mydoc123.com/p-514647.html