ASTM D3236-1988(2014) Standard Test Method for Apparent Viscosity of Hot Melt Adhesives and Coating Materials《热熔粘合剂及涂层材料表观粘度的标准试验方法》.pdf
《ASTM D3236-1988(2014) Standard Test Method for Apparent Viscosity of Hot Melt Adhesives and Coating Materials《热熔粘合剂及涂层材料表观粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3236-1988(2014) Standard Test Method for Apparent Viscosity of Hot Melt Adhesives and Coating Materials《热熔粘合剂及涂层材料表观粘度的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3236 88 (Reapproved 2014)Standard Test Method forApparent Viscosity of Hot Melt Adhesives and CoatingMaterials1This standard is issued under the fixed designation D3236; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the appar-ent viscosity of hot melt adhesives and coating ma
3、terialscompounded with additives and having apparent viscosities upto 200 000 millipascal second (mPas) (Note 3) at temperaturesup to 175C (347F).NOTE 1Although precision has not been studied, this procedure maybe adaptable to viscosities higher than the present 200 000-mPas limit andtemperatures ab
4、ove 175C (347F). Equipment described in this testmethod permits testing of materials having viscosities as high as 16 106mPas and provides temperatures up to 260C (500F).NOTE 2For petroleum waxes and their blends having apparentviscosities below 15 mPas, Test Method D445 is especially applicable.NOT
5、E 3One pascal second (Pas) = 1000 centipoise (CP); one milli-pascal second = one centipoise.1.2 The values stated in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associa
6、ted with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D445 Test Method for Kinematic Viscosity of Transparentand O
7、paque Liquids (and Calculation of Dynamic Viscos-ity)3. Terminology3.1 Definitions:3.1.1 apparent viscositythe viscosity determined by thistest method and expressed in millipascal seconds. Its valuemay vary with the spindle and rotational speed selectedbecause many hot melts are non-Newtonian.3.1.2
8、viscositythe ratio of shear stress to shear rate. Theviscosity of a liquid is a measure of the internal friction of theliquid in motion. The unit of dynamic viscosity is the pascalsecond. For a Newtonian liquid, the viscosity is constant at allshear rates. For a non-Newtonian liquid, viscosity will
9、varydepending on shear rate.4. Summary of Test Method4.1 A representative sample of the molten material to betested is maintained in a thermally controlled sample chamber.Apparent viscosity is determined under temperature equilib-rium conditions using a precision rotating spindle type viscom-eter. D
10、ata obtained at several temperatures can be plotted onappropriate semi-logarithmic graph paper and apparent viscos-ity at intermediate temperatures can be estimated.5. Significance and Use5.1 This test method distinguishes between hot melts havingdifferent apparent viscosities. It is believed that a
11、pparentviscosity determined by this procedure is related to flowperformance in application machinery operating under condi-tions of low shear rate. Apparent viscosity as determined bythis test method may not correlate well with end-use applica-tions where high shear rates are encountered.5.2 Materia
12、ls of the type described in this procedure may bequite non-Newtonian and as such, the apparent viscosity willbe a function of shear rate under the conditions of test.Although the viscometer described in this test method gener-ally operates under conditions of relatively low shear rate,differences in
13、 shear effect can exist depending upon the spindleand rotational speed conditions selected for the test program.Maximum correlation between laboratories, therefore, dependsupon testing under conditions of equivalent shear.5.3 Approximate shear rates using various spindles areshown in Table A1.1.1Thi
14、s test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.10.0A on Physical/Chemical Properties.Current edition approved May 1, 2014. Published July 2014. Originally approvedin 1973. Last previ
15、ous edition approved in 2009 as D3236 88 (2009). DOI:10.1520/D3236-88R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe A
16、STM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 Viscometer, rotating spindle type with leveling stand.36.2 Viscometer Spindles, stainless steel.36.3 Sample Chamber, with precision proportional tempera-ture
17、controller3,4that provides control accuracy of61.0C (1.8F) or better through the range from 100 to 200C(212 to 392F).6.4 Graph Paper, semi-logarithmic.7. Calibration7.1 The viscometer is precalibrated using Newtonian fluidsby the manufacturer. No zero adjustment is provided, sinceexperience has show
18、n that the zero point will not vary due tochanges in the spring. The viscometer and spindles are preci-sion equipment and should be kept from undue shock andmishandling. Physical damage to the instrument will oftenreveal itself as erratic or no oscillation of the pointer when theinstrument, with or
19、without the spindle in place, is operated inair. When operating normally, the pointer will be stable andhave free oscillation about the zero point in air.7.2 The instrument may be further calibrated using standardreference fluids. Suitable fluids are available in nominalviscosities up to 15 000 mPas
20、 at 149C (300F).5The proce-dure for instrument calibration using standard reference fluidsis that encompassed by this test method. Results obtained usingstandard reference fluids should not deviate from the nominalviscosity by more than 2 %.7.3 The temperature controller of the type recommended fort
21、his procedure is factory calibrated and has control capabilityof 60.5 % of the control point (61.0C at 175C). To furthercheck the controller and further establish controller settings,use the following procedure: Place a sufficient quantity of lowviscosity (500 mPas or less) hot melt in the sample co
22、ntainerto permit immersion of the appropriate ASTM thermometer tothe proper depth. Do not permit the thermometer bulb to rest onthe bottom of the sample container. Suitable thermometers areshown in Table 1.NOTE 4Particular care must be taken not to overflow the samplechamber when using the 100C, 76-
23、mm immersion thermometer.7.3.1 Insert the thermometer through the insulating cover ofthe sample container and hold it in place at the point requiredfor proper immersion depth. Adjust the thermal controller toprovide the desired test temperature. Rotate the thermometerduring temperature reading to mi
24、nimize the effect of thermalgradients in the sample. Continue temperature readings andcontroller adjustment until minimum deviation from test tem-perature is obtained. Minimum deviation may vary betweenlaboratories, depending upon the controller, but should in nocase exceed 60.5C (0.9F). Repeat this
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD323619882014STANDARDTESTMETHODFORAPPARENTVISCOSITYOFHOTMELTADHESIVESANDCOATINGMATERIALS 粘合剂 涂层 材料

链接地址:http://www.mydoc123.com/p-514364.html