ASTM D3104-2014 Standard Test Method for Softening Point of Pitches &40 Mettler Softening Point Method&41 《沥青软化点的标准试验方法(Mettler软化点法)》.pdf
《ASTM D3104-2014 Standard Test Method for Softening Point of Pitches &40 Mettler Softening Point Method&41 《沥青软化点的标准试验方法(Mettler软化点法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3104-2014 Standard Test Method for Softening Point of Pitches &40 Mettler Softening Point Method&41 《沥青软化点的标准试验方法(Mettler软化点法)》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3104 99 (Reapproved 2010)D3104 14Standard Test Method forSoftening Point of Pitches (Mettler Softening Point Method)1This standard is issued under the fixed designation D3104; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers the determination of the softening point of pitches having softening
3、 points in the range from 50 to180C by this test method, and gives results comparable to those obtained by Test Method D2319 above 176F (80C).1.2 The values stated in SI units are to be regarded as the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associa
4、ted with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A314 Specification for Stainless Steel Billets and Bars for For
5、gingD2319 Test Method for Softening Point of Pitch (Cube-in-Air Method)D4296 Practice for Sampling Pitch3. Summary of Test Method3.1 In this test method, the softening point is defined as the temperature at which pitch, suspended in a cylindrical cup with a6.35-mm hole in the bottom, flows downward
6、a distance of 19 mm to interrupt a light beam, as the sample is heated at a linearrate in air.4. Significance and Use4.1 Pitch does not go through a solid-liquid phase change when heated, and therefore does not have a true melting point. Asthe temperature is raised pitch gradually softens or becomes
7、 less viscous. For this reason, the determination of the softening pointmust be made by an arbitrary, but closely defined, method if the test values are to be reproducible.4.2 This test method is useful in determining the consistency of pitches as one element in establishing the uniformity ofshipmen
8、ts or sources of supply.5. Apparatus5.1 A Mettler dropping point cell3 shall be used to determine pitch softening points by this test method. These commerciallyavailable instruments consist of a control unit with a digital temperature indicator, matched furnace, sample cartridges, andaccessories. Th
9、e control unit automatically regulates the heating rate of the furnace. The softening point is indicated on the readout,and the heating program stopped, when the sample flow triggers a photocell detector.Ageneral view of the contents of the Mettleris shown in Fig. 1.5.1.1 Control UnitThis unit shall
10、 provide a continuous, linear temperature increase from 25 to 250C at a rate of 2C/min.A digital readout shall indicate the temperature to 0.1C throughout.1 This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuels, and Lubricantsand is the direct
11、responsibility ofSubcommittee D02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved May 1, 2010June 1, 2014. Published May 2010July 2014. Originally approved in 1972. Last previous edition approved in 20052010 asD3104 99 (2010). (2005). DOI: 10.1520/D3104-99R10.1
12、0.1520/D3104-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The sole source of supply of the apparatus
13、known to the committee at this time is available from the Mettler Toledo, Inc., Balances and Instruments, 69Princeton-Hightstown Rd., Hightstown, NJ 08520-0071. If you are aware of alternative suppliers, please provide this information to ASTM International Headquarters. Yourcomments will receive ca
14、reful consideration at a meeting of the responsible technical committee,1 which you may attend.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically pos
15、sible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCo
16、pyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.1.1 Control and Furnace UnitThis unit shall shall provide a continuous, linear temperature increase from 25 to 250C ata rate of 2C/min. A digital readout shall indicate the temperature t
17、o 0.1C throughout. This shall be capable of heating a one ortwo sample cup assembly,assemblies, as described in 5.1.35.1.2, at a linear rate of 2 6 0.3C/min. It shall include a sensing systemcapable of detecting the softening point with a precision of 0.1C.5.1.2 Sample Cup AssemblyA cup of chromium-
18、plated brass, or of stainless steel steel, or of aluminum, conforming to therequirements for Type 303 (UNS S30300) as prescribed in Specification A314, with the dimensions shown in Fig. 2. It shall beplaced in the assembly so that the pitch sample will flow downward a distance of 19 mm before interr
19、upting a light beam andstopping the heating program as the softening point is reached.softening point will be detected when it has flowed down a distanceof 19 mm.6. Reagents6.1 Xylene, industrial grade.6.2 Benzoic Acid.FIG. 1 General View of the Mettler FP-5/53D3104 1427. Calibration of the Mettler
20、Apparatus7.1 This step, required only occasionally, is designed to establish that the temperature indicated by the instrument is inagreement with a known standard.Aspecial cup with a bottom orifice of 2.8 mm is used instead of the one prescribed for the testingof pitch.7.2 ReagentUse either analytic
21、al reagent or primary standard grade benzoic acid for the calibration. As this material ishygroscopic it must be stored in a tightly sealed container, and replaced with fresh material from a newly opened supply ifhydration or other contamination is suspected.7.3 Procedure:7.3.1 Filling the Sample Cu
22、pPlace the cup on a clean, flat surface. Add a small amount of benzoic acid crystals and pressdown with a rod (approximately 4.5 mm in diameter). Check that the bottom orifice is completely filled. Refill and repeat thepressing step until the cup is filled with benzoic acid. Remove any crystals from
23、 the exterior of the cup.7.3.2 Heating Preheat the Mettler furnace to 121C, and maintain it at that temperature. Place the cartridge assemblycontaining the benzoic acid in position in the furnace, taking care that the slits for the light beam are properly positioned. Waitfor temperature equilibratio
24、n, that is, the furnace and the sample are in equilibrium at the preset temperature, but not less than the30 s after inserting the cartridge, start the automatic heating cycle at 0.2C/min. The temperature will rise steadily at the correctrate until the drop point is reached, and then remain steady o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD31042014STANDARDTESTMETHODFORSOFTENINGPOINTOFPITCHES40METTLERSOFTENINGPOINTMETHOD41 沥青 软化 标准 试验

链接地址:http://www.mydoc123.com/p-514081.html