ASTM D2777-2008e1 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water《D19水委员会应用试验方法的精确性及偏差测定的标准实施规范》.pdf
《ASTM D2777-2008e1 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water《D19水委员会应用试验方法的精确性及偏差测定的标准实施规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2777-2008e1 Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water《D19水委员会应用试验方法的精确性及偏差测定的标准实施规范》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2777 081Standard Practice forDetermination of Precision and Bias of Applicable TestMethods of Committee D19 on Water1This standard is issued under the fixed designation D 2777; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorially added reference to Adjunct DQCALC in Referenced Documents in November 2008.1. Scope1.1 This
3、practice establishes uniform standards for estimat-ing and expressing the precision and bias of applicable testmethods for Committee D19 on Water.1.2 Except as specified in 1.3, 1.4, and 1.5, this practicerequires the task group proposing a new test method to carryout a collaborative study from whic
4、h statements for precision(overall and single-operator standard-deviation estimates) andbias can be developed. This practice provides general guidanceto task groups in planning and conducting such determinationsof precision and bias.1.3 If a full-scale collaborative study is not technicallyfeasible,
5、 due to the nature of the test method or instability ofsamples, the largest feasible scaled-down collaborative studyshall be conducted to provide the best possible limited basis forestimating the overall and single-operator standard deviations.1.3.1 Examples of acceptable scaled-down studies are the
6、local-area studies conducted by Subcommittee D19.24 onmicrobiological methods because of inherent sample instabil-ity. These studies involve six or more completely independentlocal-area analysts who can begin analysis of uniform samplesat an agreed upon time.1.3.2 If uniform samples are not feasible
7、 under any circum-stances, a statement of single-operator precision will meet therequirements of this practice. Whenever possible, this state-ment should be developed from data generated by independentmultiple operators, each doing replicate analyses on indepen-dent samples (of a specific matrix typ
8、e), which generally fallwithin specified concentration ranges (see 7.2.5.2 (3).1.3.3 This practice is not applicable to methodology involv-ing continuous sampling or continuous measurement, or both,of specific constituents and properties.1.3.4 This practice is also not applicable to open-channelflow
9、 measurements.1.4 A collaborative study that satisfied the requirements ofthe version of this practice in force when the study wasconducted will continue to be considered an adequate basis forthe precision-and-bias statement required in each test method.If the study does not satisfy the current mini
10、mum requirementsfor a collaborative study, a statement listing the studysdeficiencies and a reference to this paragraph shall be includedin the precision-and-bias statement as the basis for an exemp-tion from the current requirements.1.5 This paragraph relates to special exemptions not clearlyaccept
11、able under 1.3 or 1.4. With the approval of CommitteeD19 on the recommendation of the Results Advisor and theTechnical Operations Section of the Executive Subcommitteeof Committee D19, a statement giving a compelling reasonwhy compliance with all or specific points of this practicecannot be achieved
12、 will meet both ASTM requirements (1)2and the related requirements of this practice. In addition,Committee D19, through a Main Committee ballot, mayapprove publication of a “Preliminary” Standard Method for aperiod not to exceed 5 years. Preliminary Standards mustcontain a minimum of a single-operat
13、or precision-and-biasstatement and a Quality Control section based on the singleoperator data. Publication of a Preliminary Standard is condi-tional on the approval of a full D 2777 collaborative studydesign for the standard. Precision-and-bias statements autho-rized by this paragraph shall include
14、the date of approval byCommittee D19.1.6 In principle, all test methods are covered by thispractice.1.7 In Section 12 this practice shows exemplary precision-and-bias-statement formats for: (1) test methods yielding anumerical measure, (2) test methods yielding a non-numericalreport of success or fa
15、ilure based on criteria specified in theprocedure, and (3) test methods specifying that procedures inanother ASTM test method are to be used with only insignifi-cant modifications.1.8 All studies, even those exempt from some requirementsunder 1.3 or 1.5, shall receive approval from the ResultsAdviso
16、r before being conducted (see Section 8) and aftercompletion (see Section 13).1This practice is under the jurisdiction of ASTM Committee D19 on Water andis the direct responsibility of Subcommittee D19.02 on Quality Systems, Specifi-cation, and Statistics.Current edition approved Jan. 15, 2008. Publ
17、ished February 2008. Originallyapproved in 1969. Last previous edition approved in 2006 as D 2777 06.2The boldface numbers in parentheses refer to the list of standards at the end ofthis practice.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Uni
18、ted States.1.9 This practice satisfies the QC requirements of Practice D5847.1.10 It is the intent of this practice that task groups makeevery effort to retain all the data from their round-robin studies.Values should not be eliminated unless solid evidence exists fortheir exclusion. The Results Adv
19、isor should work closely withthe task groups to effect this goal.2. Referenced Documents2.1 ASTM Standards:3D 1129 Terminology Relating to WaterD 1141 Practice for the Preparation of Substitute OceanWaterD 1193 Specification for Reagent WaterD 4375 Practice for Basic Statistics in Committee D19 onWa
20、terD 5790 Test Method for Measurement of Purgeable OrganicCompounds in Water by Capillary Column GasChromatography/Mass SpectrometryD 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisD 5905 Practice for the Preparation of Substitute Wastewa-terD 609
21、1 Practice for 99 %/95 % Interlaboratory DetectionEstimate (IDE) for Analytical Methods with NegligibleCalibration ErrorD 6512 Practice for Interlaboratory Quantitation EstimateE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 178 Practice for Dealing With Outlying Observat
22、ionsE 456 Terminology Relating to Quality and StatisticsE 1169 Practice for Conducting Ruggedness Tests2.2 ASTM Adjuncts:DQCALC Microsoft Excel-based software for the Inter-laboratory Quantitation Estimate (IQE)43. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to T
23、erminologies D 1129, D 4375 and E 456, andPractice E 177.3.2 Definitions of Terms Specific to This Standard:3.2.1 accuracya measure of the degree of conformity ofa single test result generated by a specific procedure to theassumed or accepted true value, and includes both precisionand bias.3.2.2 bia
24、sthe persistent positive or negative deviation ofthe average value of a test method from the assumed oraccepted true value.3.2.3 laboratorya single and completely independent ana-lytical system with its own specific apparatus, source ofreagents, set of internal standard-operating procedures, etc.Dif
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD27772008E1STANDARDPRACTICEFORDETERMINATIONOFPRECISIONANDBIASOFAPPLICABLETESTMETHODSOFCOMMITTEED19ONWATERD19

链接地址:http://www.mydoc123.com/p-513482.html