ASTM D596-2001(2011) Standard Guide for Reporting Results of Analysis of Water《水分析结果报告的标准指南》.pdf
《ASTM D596-2001(2011) Standard Guide for Reporting Results of Analysis of Water《水分析结果报告的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D596-2001(2011) Standard Guide for Reporting Results of Analysis of Water《水分析结果报告的标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D596 01 (Reapproved 2011)Standard Guide forReporting Results of Analysis of Water1This standard is issued under the fixed designation D596; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This guide provides guidelines for reporting inorganica
3、nd organic results of analyses of drinking water, waste water,process water, ground water, and surface water, and so forth, tolaboratory clients in a complete and systematic fashion.1.2 The reporting of bacterial and radiological data are notaddressed in this guide.1.3 The commonly used data qualifi
4、ers for reviewing andreporting information are listed and defined. Client and labo-ratory specific requirements may make use of other qualifiers.This guide does not preclude the use of other data qualifiers.1.4 This guide discusses procedures for and specific prob-lems in the reporting of low level
5、data, potential errors (TypeI and Type II), and reporting data that are below the calculatedmethod detection limit and above the analyte.1.4.1 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.2. Referenced Documents2.1 ASTM Stand
6、ards:2D933 Practice for Reporting Results of Examination andAnalysis of Water-Formed DepositsD1129 Terminology Relating to WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3856 Guide for Good Laboratory Practices in Laborato-ries Engaged
7、 in Sampling and Analysis of WaterD4210 Practice for Intralaboratory Quality Control Proce-dures and a Discussion on Reporting Low-Level Data3D4460 Practice for Calculating Precision Limits WhereValues are Calculated from Other Test MethodsD4840 Guide for Sample Chain-of-Custody ProceduresD5792 Prac
8、tice for Generation of Environmental Data Re-lated to Waste Management Activities: Development ofData Quality ObjectivesD6091 Practice for 99 %/95 % Interlaboratory DetectionEstimate (IDE) for Analytical Methods with NegligibleCalibration ErrorE29 Practice for Using Significant Digits in Test Data t
9、oDetermine Conformance with Specifications3. Terminology3.1 DefinitionsFor definitions of terms used in this prac-tice, refer to Terminology D1129.3.2 Definitions of Terms Specific to This Standard:3.2.1 surrogatescompounds that are similar to analytes ofinterest in chemical composition and behavior
10、, separation, andmeasurements, but that are not normally found in environmen-tal samples.NOTE 1These compounds are added to blanks, standards, samples, orspiked samples prior to analysis to confirm the proper operation of theanalytical system.3.2.2 Type I errora statement that a substance is present
11、when it is not.3.2.3 Type II errora statement that a substance was notpresent (was not found) when the substance was present.4. Significance and Use4.1 The proper use of analytical data requires adequatedocumentation of all inputs, that is, the source and history ofthe sample, laboratory performing
12、the analysis, method ofanalysis, date of analysis, precision and bias of the measure-ments, and related quality assurance information.4.2 In order to have defensible data, the report must becomplete and accurate, providing adequate information toevaluate the quality of the data and contain supportin
13、g infor-mation that documents sampling and analysis procedures.4.3 This guide contains some of the common data qualifiersor “flags” commonly used by laboratories following the GoodLaboratory Practices, the Government Contract program, or1This guide is under the jurisdiction of ASTM Committee D19 on
14、Water and isthe direct responsibility of Subcommittee D19.02 on Quality Systems, Specification,and Statistics.Current edition approved May 1, 2011. Published June 2011. Originallyapproved in 1940. Last previous edition approved in 2006 as D596 01(2006).DOI: 10.1520/D0596-01R11.2For referenced ASTM s
15、tandards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon w
16、ww.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.found in the commercial laboratories. Examples of thesequalifiers are the use of (E) for estimated value, (U) foranalyzed for but not detected, and (B) for analyte was found
17、 inthe blank (see 8.11). The qualifiers included in this guideshould help the laboratory and its customers to better under-stand each other by using standardized qualifiers.4.4 Practice D933 is a comprehensive practice for reportingwater-formed constituents such as metal oxides, acid anhy-drides, an
18、d others.5. Sample Documentation5.1 Information regarding the source and history of thesample to be included in the analytical report should define thesample and include the following, as appropriate:5.1.1 Laboratory performing analysis,5.1.2 Name and address of organization or person request-ing an
19、alysis,5.1.3 Specific location of sampling and complete identifica-tion of sample,5.1.4 Date and time of sampling,5.1.5 Sample identification number, and5.1.6 Sampling method, treatment, and preservation.5.2 In addition to the information in 5.1, the followinginformation should be included as approp
20、riate:5.2.1 Identification of sampling organization and individualsampler,5.2.2 Pressure and temperature of system sampled,5.2.3 Flow rate of water in a stream, outfall, pipe, and soforth.5.2.4 Copies of sampling logs with signatures,5.2.5 Chain-of-custody forms with signatures (see GuideD4840),5.2.
21、6 Results of field measurements, and5.2.7 Description information (color, odor, and so forth)clearly presented.5.2.8 The information about the sample documented in thereport should be complete enough to provide direct unabridgedlinks to underlying documents (such as chain-of-custody re-cords and fie
22、ld logs) and information (such as name of sampler,lot numbers of the sample bottles, and preservatives).6. Analysis Documentation6.1 The laboratory system shall provide enough informationto the user or reviewer so that all of the events that couldinfluence the quality of the data can be reconstructe
23、d. The usermay not need to have the information communicated directly tothem, but it must be available upon request. Such informationshould describe how effectively all procedures were carried outand how processes were controlled so that they meet industryand government standards for performance.6.2
24、 As described in Guide D3856, the test method ofanalysis should be specified in the analytical report for eachdetermination performed on a sample. A reference of sufficientdefinition or a copy of the test method should be provided tothe requestor of the analytical services.6.3 The report should note
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD59620012011STANDARDGUIDEFORREPORTINGRESULTSOFANALYSISOFWATER 水分 结果 报告 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-511926.html