1、Designation: D 1004 07Standard Test Method forTear Resistance (Graves Tear) of Plastic Film and Sheeting1This standard is issued under the fixed designation D 1004; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method2covers the determination
3、 of the tearresistance of flexible plastic film and sheeting at very low ratesof loading, 51 mm 2 in./min. and is designed to measure theforce to initiate tearing. The specimen geometry of this testmethod produces a stress concentration in a small area of thespecimen. The maximum stress, usually fou
4、nd near the onset oftearing, is recorded as the tear resistance in newtons orpounds-force. The method is not applicable for film orsheeting material where brittle failures occur during testing orwhere maximum extension is greater than 101.6 mm 4 in.NOTE 1Film has been arbitrarily defined as sheeting
5、 having nominalthickness not greater than 0.25 mm 0.010 in.1.2 Constant-Rate-of-Grip Separation TestThis testmethod employs a constant rate of separation of the gripsholding the test specimen.1.2.1 Specimen extension may be measured in this testmethod by grip separation.1.3 The values stated in SI u
6、nits are to be regarded as thestandard. The values given in brackets are provided forinformation only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and he
7、alth practices and determine the applica-bility of regulatory limitations prior to use.NOTE 2There is no similar or equivalent ISO standard.2. Referenced Documents2.1 ASTM Standards:3D 618 Practice for Conditioning Plastics for TestingD 882 Test Method for Tensile Properties of Thin PlasticSheetingD
8、 883 Terminology Relating to PlasticsD 4000 Classification System for Specifying Plastic Mate-rialsD 5947 Test Methods for Physical Dimensions of SolidPlastics SpecimensE4 Practices for Force Verification of Testing MachinesE 691 Practice for Conducting an Interlaboratory Study toDetermine the Preci
9、sion of a Test Method2.2 ASTM Adjuncts:Die Drawings43. Terminology3.1 Definitions:Definitions of terms applying to this test method appear inTerminology D 883.4. Summary of Test Method4.1 The force to initiate tearing across a specific geometryof a film or sheeting specimen is measured using a const
10、ant-rate-of-grip separation machine. The force necessary to initiatethe tear is calculated from the load-time or load-displacementdata.5. Significance and Use5.1 Tear resistance of plastic film or sheeting is a complexfunction of its ultimate resistance to rupture. The specimengeometry and speed of
11、testing in this test method are controlledto produce tearing in a small area of stress concentration atrates far below those usually encountered in service. Experi-ence has shown the test to have its best reliability for materialswhich do not have brittle failure or do not elongate greater thantwo h
12、undred percent during testing.5.2 The data from this test method furnish comparativeinformation for ranking the tearing resistance of plastic speci-mens of similar composition. Actual use performance intearing of some plastics may not necessarily correlate with datafrom this test method.1This test m
13、ethod is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.19 on Film and Sheeting.Current edition approved April 1, 2007. Published April 2007. Originallyapproved in 1949. Last previous edition approved in 2003 as D 1004 03.2The following r
14、eference may be of interest in connection with this test method:Graves, F. L., “The Evaluation of Tear Resistance in Elastomers,” India RubberWorld, Vol 111, No. 3, December 1944, pp. 305308.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serv
15、iceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from ASTM International Headquarters. Order Adjunct No.ADJD1004.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International
16、, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 The resistance to tear of plastic film and sheeting, whilepartly dependent upon thickness, has no simple correlationwith specimen thickness. Hence, tearing forces measured innewtons or pounds-force cannot be no
17、rmalized over a widerange of specimen thickness without producing misleadingdata as to the actual tearing resistance of the material. Datafrom this test method are comparable only from specimens,which vary by no more than 610 % from the nominal oraverage thickness of all specimens tested. Therefore,
18、 thetearing resistance is expressed in maximum newtons orpounds-force of force to tear the specimen.5.4 The tear resistance of plastic film may be a specificationthat requires the use of this test method, but with someprocedural modifications that take precedence when adheringto the specification. T
19、herefore, it is advisable to refer to thatmaterial specification before using this test method. Table 1 ofClassification System D 4000 lists the ASTM materials stan-dards that currently exist.6. Apparatus6.1 Testing MachineA testing machine of the constantrate-of crosshead-movement type and comprisi
20、ng essentiallythe following:6.1.1 Fixed MemberA fixed or essentially stationarymember carrying one grip.6.1.2 Movable MemberA movable member carrying asecond grip.6.1.3 GripsPreferably, a set of self-aligning grips forholding the test specimen between the fixed member and themovable member of the te
21、sting machine. The grips shouldminimize both slippage and uneven stress distribution.6.1.3.1 Fixed grips are rigidly attached to the fixed andmovable members of the testing machine. Fixed grips may beused if extreme care is taken to ensure that the test specimen isinserted and clamped so that the lo
22、ng axis of the test specimencoincides with the direction of pull through the center line ofthe grip assembly.6.1.3.2 Self-aligning grips are attached to the fixed andmovable member of the testing machine in such a manner thatthey will move freely into alignment as soon as any load isapplied so that
23、the long axis of the test specimen will coincidewith the direction of the applied pull through the center line ofthe grip assembly.NOTE 3The specimens should be aligned as perfectly as possible withthe direction of pull so that no rotary motion that may induce slippage willoccur in the grips; there
24、is a limit to the amount of misalignmentself-aligning grips will accommodate.NOTE 4Grips lined with thin rubber have been used successfully.Grips may be of the self-tightening type. In cases where specimensfrequently fail at the edge of the grips, the radius of curvature of the edgesof the grips may
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD10042007STANDARDTESTMETHODFORTEARRESISTANCEGRAVESTEAROFPLASTICFILMANDSHEETING 塑料薄膜 塑料 薄板 撕裂 强度 PDF

链接地址:http://www.mydoc123.com/p-509113.html