ASTM C919-2012 Standard Practice for Use of Sealants in Acoustical Applications 《声学设备中密封料使用的标准实施规范》.pdf
《ASTM C919-2012 Standard Practice for Use of Sealants in Acoustical Applications 《声学设备中密封料使用的标准实施规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C919-2012 Standard Practice for Use of Sealants in Acoustical Applications 《声学设备中密封料使用的标准实施规范》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:C91908 Designation: C919 12Standard Practice forUse of Sealants in Acoustical Applications1This standard is issued under the fixed designation C919; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is a guide provides information for the use of sealants to reduce the sound transmission characteristics ofinterio
3、r walls, ceilings, and floors by proper application of sealants to joints, voids, and penetrations normally found in buildingconstruction, which are commonly referred to as “flanking paths.”1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It
4、is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by otherorganizations
5、.2. Referenced Documents2.1 ASTM Standards:2C570Specification for Oil- and Resin-Base Caulking Compound for Building ConstructionC634 Terminology Relating to Building and Environmental AcousticsC717 Terminology of Building Seals and SealantsC834 Specification for Latex SealantsC920 Specification for
6、 Elastomeric Joint SealantsC1193 Guide for Use of Joint SealantsC1520 Guide for Paintability of Latex SealantsC1620 Specification for Aerosol Polyurethane and Aerosol Latex Foam SealantsC1642 Practice for Determining Air Leakage Rates of Aerosol Foam Sealants and Other Construction Joint Fill and In
7、sulationMaterialsE90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and ElementsE336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in BuildingsE413 Classification for Rating Sound InsulationE497Practice for Installing Sound
8、-Isolating Lightweight Partitions Classification for Rating Sound Insulation2.2 DHUD Standards:HUD Standard:3HUD Minimum Property Standards for One and Two Family Housing, Section 4900.1HUD Minimum Property Standard for Multi Family Housing, Section 4910.1HUD Minimum Property Standard for Care Type
9、Housing, Section 4920.1HUD Minimum Property Standards for Housing,Section 4910.12.3 IBC Standard:4International Building Code (IBC), Section 12073. Significance and Use3.1Construction utilizing lightweight walls and floors can have undesirable sound transmission characteristics if care is not takent
10、o seal joints and voids that are common to this type of construction. By sealing these penetrations the transmission of sound canbe diminished.1This practice is under the jurisdiction ofASTM Committee C24 on Building Seals and Sealants and is the direct responsibility of Subcommittee C24.10 on Speci
11、fications,Guides and Practices.Current edition approved MayJune 1, 2008.2012. Published June 2008.July 2012. Originally approved in 1979. Last previous edition approved in 20022008 as C919 028.DOI: 10.1520/C0919-08.10.1520/C0919-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org
12、, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3Available from Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.4Available from Internationa
13、l Code Council (ICC), 500 New Jersey Ave., NW, 6th Floor, Washington, DC 20001, http:/www.iccsafe.org.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technic
14、ally possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box
15、 C700, West Conshohocken, PA 19428-2959, United States.4.Sound Transmission Class4.1The construction industry has adopted Sound Transmission Class (STC) units (defined in Definitions Terminology3.1 DefinitionsFor definitions of terms used in this recommended practice, see Terminologies C717 and C634
16、) to rate thesound barrier properties of walls, ceilings, and floors. The STC is determined in accordance with Classification .4. Significance and Use4.1 Walls, ceilings, and floors in building construction, especially those that are of lightweight construction, and that aredesigned to reduce or lim
17、it sound transmission, can have undesirable sound transmission characteristics if care is not taken to sealjoints, voids, and penetrations that typically occur. Unsealed joints, voids, and penetrations will substantially increase the soundtransmission characteristics of these types of construction.
18、By sealing them the transmission of sound can be substantiallydiminished by eliminating “flanking paths.”5. Sound Transmission Requirements5.1 The construction industry has adopted Sound Transmission Class (STC) units, as defined in Terminology C634, to rate thesound transmission properties of walls
19、, ceilings, and floors. The STC is determined in accordance with Classification E413. Thetest data are obtained in accordance with Test Methods E90 or and E336. Note1For example, The Department of Housing andUrban Development (DHUD) has issued the following three standards dealing with the STC limit
20、ation in various housing units:HUD Minimum Property Standard for One and Two Family Housing, Section 4900.1; HUD Minimum Property Standard for MultiFamily Housing, Section 4910.1; and HUD Minimum Property Standard for Care Type Housing, Section 4920.15.Need to Seal Openings5.1The effect of unsealed
21、openings on the STC of partition walls is shown in5.2 Various building and other governmental adopted codes include requirements for sound transmission.5.2.1 For example, the International Building Code (IBC), Section 1207, has requirements for the amount of sound that isallowed to be transmitted th
22、rough the interior walls, partitions, and floor and ceiling assemblies between adjacent dwelling unitsand between them and public spaces of a building.5.2.2 Additionally, the department of Housing and Urban Development (HUD) has the following standard for STC limitationsfor various housing units: HU
23、D Minimum Property Standards for Housing, Section 4910.1.6. Why Seal Openings?6.1 The sound transmission of a wall, ceiling, or floor, no matter how well built, can be substantially defeated by the presenceof unsealed joints, voids, and penetrations. Fig. 1 . This chart also shows the improvement of
24、 the STC when openings are sealed.It should be recognized for slit openings that the STC values may be different from the STC value for a hole opening.5.2Fig. 2 shows examples of how sound travels through openings in walls and how sealing may serve to minimize soundtransmission. Further examples may
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC9192012STANDARDPRACTICEFORUSEOFSEALANTSINACOUSTICALAPPLICATIONS 声学 设备 密封 使用 标准 实施 规范 PDF

链接地址:http://www.mydoc123.com/p-508793.html