ASTM C656-2007(2013) Standard Specification for Structural Insulating Board Calcium Silicate《硅酸钙结构隔热板的标准规格》.pdf
《ASTM C656-2007(2013) Standard Specification for Structural Insulating Board Calcium Silicate《硅酸钙结构隔热板的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C656-2007(2013) Standard Specification for Structural Insulating Board Calcium Silicate《硅酸钙结构隔热板的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C656 07 (Reapproved 2013)Standard Specification forStructural Insulating Board, Calcium Silicate1This standard is issued under the fixed designation C656; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers structural insulating board forgeneral thermal insulating, fire-resistive, and marine bulkheada
3、pplications. The rigid, preformed structural insulating board isfor use at temperatures up to 1700F (927C). For specificapplications, the actual temperature limit shall be agreed uponbetween the manufacturer and the purchaser.1.2 The structural insulating board maintains its structuralintegrity afte
4、r immersion in water.1.3 Rapid cycling over a wide temperature range is notrecommended because of potential damage due to thermalshock.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided fo
5、r information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of r
6、egulatory limitations prior to use.1.6 When the installation or use of thermal insulationmaterials, accessories and systems, may pose safety or healthproblems, the manufacturer shall provide the user appropriatecurrent information regarding any known problems associatedwith the recommended use of th
7、e companys products, andshall also recommend protective measures to be employed intheir safe utilization. The user shall establish appropriate safetyand health practices and determine the applicability of regula-tory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2C165 Test Meth
8、od for Measuring Compressive Properties ofThermal InsulationsC168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC203 Test Methods for Breaking Load and Flexural Proper-
9、ties of Block-Type Thermal InsulationC303 Test Method for Dimensions and Density of Pre-formed Block and BoardType Thermal InsulationC356 Test Method for Linear Shrinkage of Preformed High-Temperature Thermal Insulation Subjected to SoakingHeatC390 Practice for Sampling and Acceptance of ThermalInsu
10、lation LotsC411 Test Method for Hot-Surface Performance of High-Temperature Thermal InsulationC447 Practice for Estimating the Maximum Use Tempera-ture of Thermal InsulationsC518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC1045 Practice for C
11、alculating Thermal Transmission Prop-erties Under Steady-State ConditionsC1058 Practice for Selecting Temperatures for Evaluatingand Reporting Thermal Properties of Thermal InsulationD1037 Test Methods for Evaluating Properties of Wood-Base Fiber and Particle Panel MaterialsE136 Test Method for Beha
12、vior of Materials in a VerticalTube Furnace at 750C3. Terminology3.1 DefinitionsThe definitions in Terminology C168 shallapply to the terms used in this specification.4. Classification4.1 The structural insulating boards shall be of the followingtypes:4.1.1 Type IMaximum use temperature 1400F (760C)
13、.4.1.2 Type IIMaximum use temperature 1700F (927C).4.2 The structural insulating boards shall be of the followinggrades:4.2.1 Grade 1Typical density 36 lb/ft3(577 kg/m3).4.2.2 Grade 2Typical density 46 lb/ft3(737 kg/m3).4.2.3 Grade 3Typical density 60 lb/ft3(961 kg/m3).1This specification is under t
14、he jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.20 onHomogeneous Inorganic Thermal Insulations.Current edition approved March 1, 2013. Published March 2013. Originallyapproved in 1970. Last previous edition approved in 2007 as C656 07.
15、DOI:10.1520/C0656-07R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Bar
16、r Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2.4 Grade 4Typical density 14 lb/ft3(224 kg/m3).4.2.5 Grade 5Typical density 18 lb/ft3(288 kg/m3).4.2.6 Grade 6Typical density 28 lb/ft3(449 kg/m3).4.2.7 Grade 7Typical density 40 lb/ft3(641 kg/m3).4.2.8 Grade 8Typical de
17、nsity 60 lb/ft3(961 kg/m3).5. Ordering Information5.1 The type, grade, and dimensions shall be specified bythe purchaser.5.2 When a certification or test report, or both, are required,it shall be specified by the purchaser.6. Materials and Manufacture6.1 Calcium silicate structural insulating board
18、shall becomposed of hydrated calcium silicate with natural or man-made fibers or fillers, or a combination thereof. Asbestos shallnot be used as an ingredient or component of the product.7. Other Requirements7.1 Calcium silicate structural insulating board shall con-form to the physical and mechanic
19、al requirements specified inTable 1.8. Dimensions and Permissible Variations8.1 Calcium silicate structural insulating board is typicallyavailable in lengths 48 or 96 in. (1219 or 2438 mm), widths of24 or 48 in. (610 or 1219), and thicknesses from12 to 3in. (13to 76 mm).8.2 Dimensions shall be withi
20、n the following tolerances ofspecified values:Length Width Thickness18 in. (3 mm) 18 in. (3 mm) 116 in. (1.5 mm)9. Workmanship, Finish, and Appearance9.1 Calcium silicate structural insulating boards shall nothave visible defects, such as major cracks, lumps, or excessivedeparture from planeness, wh
21、ich adversely affect service quali-ties.10. Qualification Requirements10.1 Unless otherwise specified, the following requirementsshall be employed for the purpose of initial material or productqualification.10.1.1 Compressive strength,10.1.2 Screw holding strength,10.1.3 Linear shrinkage and tempera
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC65620072013STANDARDSPECIFICATIONFORSTRUCTURALINSULATINGBOARDCALCIUMSILICATE 硅酸 结构 隔热板 标准 规格 PDF
链接地址:http://www.mydoc123.com/p-507928.html