ASTM C513-2011 Standard Test Method for Obtaining and Testing Specimens of Hardened Lightweight Insulating Concrete for Compressive Strength《获取并检测硬化轻质绝缘混凝土抗压强度试验样本的标准方法》.pdf
《ASTM C513-2011 Standard Test Method for Obtaining and Testing Specimens of Hardened Lightweight Insulating Concrete for Compressive Strength《获取并检测硬化轻质绝缘混凝土抗压强度试验样本的标准方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C513-2011 Standard Test Method for Obtaining and Testing Specimens of Hardened Lightweight Insulating Concrete for Compressive Strength《获取并检测硬化轻质绝缘混凝土抗压强度试验样本的标准方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 513 11Standard Test Method forObtaining and Testing Specimens of Hardened LightweightInsulating Concrete for Compressive Strength1This standard is issued under the fixed designation C 513; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This
3、 test method covers obtaining, preparing, and test-ing specimens of hardened, lightweight, insulating concretemade with either lightweight aggregate conforming to Speci-fication C332 or using preformed foam made from a foamingagent conforming to Specification C869 and having an oven-dry density not
4、exceeding 800 kg/m350 lb/ft3.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may r
5、esult in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulator
6、y limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C39/C39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC88 Test Method for Soundness of Aggregates by Use ofSodium Sulfate or Magnesium SulfateC125 Terminology Relating to Concrete and Concrete Ag-gregates
7、C332 Specification for Lightweight Aggregates for Insulat-ing ConcreteC617 Practice for Capping Cylindrical Concrete SpecimensC670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC869 Specification for Foaming Agents Used in MakingPreformed Foam for Cel
8、lular ConcreteC1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic Cements3. Terminology3.1 Definitions3.1.1 For definitions of terms used in this test method, referto Terminology C125.4. Significance and Use4.1 This test met
9、hod is used to determine the compressivestrength of hardened lightweight insulating concrete usingsamples taken from the field. The test results can be used todetermine specification compliance when results of tests onspecimens molded at the time of construction are not availableor are defective, an
10、d to establish the strength properties ofexisting construction.5. Apparatus5.1 Masonry or Carpenters Saw, for removing a samplefrom hardened concrete and cutting cubes from the sample. Acore drill is permitted for concrete thicker than 150 mm 6 in.5.2 Testing Machine, conforming to the requirements
11、in TestMethod C39/C39M.5.3 Scales and Weights, used in weighing specimens shallconform to Specification C1005.5.4 Drying Oven, conforming to the requirements in TestMethod C88.6. Sampling6.1 Remove a sufficiently large sample, from each samplelocation, so that at least four test specimens for compre
12、ssivestrength, and one for density (unit weight), can be preparedwithout the inclusion of any concrete that has been cracked,spalled, undercut, or otherwise damaged. The sample shall beof such length and width as to permit the cubes and prisms to1This test method is under the jurisdiction of ASTM Co
13、mmittee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.21 on Lightweight Aggregates and Concrete.Current edition approved Oct. 1, 2011. Published November 2011. Originallyapproved in 1963. Last previous edition approved in 1995 as C 513 89(1995).DOI: 10.15
14、20/C051311.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Dri
15、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.be cut therefrom without approaching any edge of the samplecloser than 25 mm 1 in. Unless otherwise specified, thesample shall not be obtained until the concrete is at least 14days old. Indicate the casting direction on the sample.7. T
16、est Specimens7.1 Compressive strength specimens shall be cubes not lessthan 50 mm 2 in., nor more than 100 mm 4 in. on a side.The dimensions of the cubes shall be equal to the thickness ofthe concrete slab unless that thickness exceeds 100 mm 4 in.,in which case the depth of the specimen shall be re
17、duced to 100mm 4 in. by sawing off the lower portion as placed. Thecasting direction shall be marked on each prepared cube so thatload can be applied in the direction of casting.7.2 Specimens for density (unit weight) determination shallbe oven-dry prism-shaped specimens with a volume of at least650
18、 mL 40 in.3.8. Preparation of Test Specimens8.1 The surfaces of compressive strength specimens thatwill be in contact with the bearing surfaces of the testingmachine shall be plane within 0.5 mm 0.02 in.). Theplaneness of the bearing surfaces of the specimens shall bechecked by means of a straighted
19、ge and feeler gauge, makingmeasurements across both diagonals of the bearing faces of thecube. If the bearing surfaces depart from a plane more than 0.5mm 0.02 in., they shall be ground to within this tolerance orcapped with materials conforming to Specification C617. Thecapped surface shall be plan
20、e within 0.05 mm 0.002 in. (Note1). The surface of the specimen in contact with the lowerbearing block of the testing machine shall not depart fromperpendicularity to the axis by more than 1 (approximatelyequivalent to 0.8 mm 0.03 in. in 50 mm 2 in. or 1.7 mm0.07 in.) in 100 mm 4 in.), and the combi
21、ned departure ofthe two bearing surfaces from perpendicularity to the axis shallnot exceed 3. The difference between the longest and shortestcube edge shall not exceed 3 mm 18 in.NOTE 1These relatively low-strength materials can tolerate greaterdeviation from planeness of bearing surfaces without af
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC5132011STANDARDTESTMETHODFOROBTAININGANDTESTINGSPECIMENSOFHARDENEDLIGHTWEIGHTINSULATINGCONCRETEFORCOMPRESSIVESTRENGTH

链接地址:http://www.mydoc123.com/p-466904.html