ASTM C231 C231M-2010 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《压力法测定新拌混凝土中空气含量的标准试验方法》.pdf
《ASTM C231 C231M-2010 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《压力法测定新拌混凝土中空气含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C231 C231M-2010 Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method《压力法测定新拌混凝土中空气含量的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C231/C231M 10Standard Test Method forAir Content of Freshly Mixed Concrete by the PressureMethod1This standard is issued under the fixed designation C231/C231M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers determina
3、tion of the air contentof freshly mixed concrete from observation of the change involume of concrete with a change in pressure.1.2 This test method is intended for use with concretes andmortars made with relatively dense aggregates for which theaggregate correction factor can be satisfactorily deter
4、mined bythe technique described in Section 6. It is not applicable toconcretes made with lightweight aggregates, air-cooled blast-furnace slag, or aggregates of high porosity. In these cases, TestMethod C173/C173M should be used. This test method is alsonot applicable to nonplastic concrete such as
5、is commonly usedin the manufacture of pipe and concrete masonry units.1.3 The text of this test method references notes andfootnotes that provide explanatory information. These notesand footnotes (excluding those in tables and figures) shall notbe considered as requirements of this standard.1.4 The
6、values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the stan
7、dard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. (WarningF
8、reshhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.)22. Referenced Documents2.1 ASTM Standards:3C31/C31M Practice for Making and Curing Concrete TestSpecimens in the FieldC138/C138M Test Method for Density (Unit Weight),Yield, and A
9、ir Content (Gravimetric) of ConcreteC143/C143M Test Method for Slump of Hydraulic-CementConcreteC172 Practice for Sampling Freshly Mixed ConcreteC173/C173M Test Method for Air Content of FreshlyMixed Concrete by the Volumetric MethodC192/C192M Practice for Making and Curing ConcreteTest Specimens in
10、 the LaboratoryC670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsE177 Practice for Use of the Terms Precision and Bias inASTM Test Methods3. Significance and Use3.1 This test method covers the determination of the aircontent of freshly mixed concrete
11、. The test determines the aircontent of freshly mixed concrete exclusive of any air that mayexist inside voids within aggregate particles. For this reason, itis applicable to concrete made with relatively dense aggregateparticles and requires determination of the aggregate correctionfactor (see 6.1
12、and 9.1).3.2 This test method and Test Method C138/C138M andC173/C173M provide pressure, gravimetric, and volumetricprocedures, respectively, for determining the air content offreshly mixed concrete. The pressure procedure of this testmethod gives substantially the same air contents as the othertwo
13、test methods for concretes made with dense aggregates.3.3 The air content of hardened concrete may be eitherhigher or lower than that determined by this test method. This1This test method is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibil
14、ity of SubcommitteeC09.60 on Testing Fresh Concrete.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 1949. Last previous edition approved in 2009 as C231/C231M09b.DOI: 10.1520/C0231_C0231M-10.2Section on Safety Precautions, Manual of Aggregate and Concrete Testin
15、g,Annual Book of ASTM Standards, Vol 04.02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Cha
16、nges section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.depends upon the methods and amount of consolidation effortapplied to the concrete from which the hardened concretespecimen is taken; uni
17、formity and stability of the air bubbles inthe fresh and hardened concrete; accuracy of the microscopicexamination, if used; time of comparison; environmentalexposure; stage in the delivery, placement and consolidationprocesses at which the air content of the unhardened concreteis determined, that i
18、s, before or after the concrete goes througha pump; and other factors.4. Apparatus4.1 Air MetersThere are available satisfactory apparatusof two basic operational designs employing the principle ofBoyles law. For purposes of reference herein these aredesignated Meter Type A and Meter Type B.4.1.1 Me
19、ter Type AAn air meter consisting of a measuringbowl and cover assembly (see Fig. 1) conforming to therequirements of 4.2 and 4.3. The operational principle of thismeter consists of introducing water to a predetermined heightabove a sample of concrete of known volume, and theapplication of a predete
20、rmined air pressure over the water. Thedetermination consists of the reduction in volume of the air inthe concrete sample by observing the amount the water level islowered under the applied pressure, the latter amount beingcalibrated in terms of percent of air in the concrete sample.4.1.2 Meter Type
21、 BAn air meter consisting of a measuringbowl and cover assembly (see Fig. 2) conforming to therequirements of 4.2 and 4.3. The operational principle of thismeter consists of equalizing a known volume of air at a knownpressure in a sealed air chamber with the unknown volume ofair in the concrete samp
22、le, the dial on the pressure gauge beingcalibrated in terms of percent air for the observed pressure atwhich equalization takes place. Working pressures of 50 to 205kPa 7.5 to 30.0 psi have been used satisfactorily.4.2 Measuring BowlThe measuring bowl shall be essen-tially cylindrical in shape, made
23、 of steel, hard metal, or otherhard material not readily attacked by the cement paste, havinga minimum diameter equal to 0.75 to 1.25 times the height, anda capacity of at least 6.0 L 0.20 ft3. It shall be flanged orotherwise constructed to provide for a pressure tight fitbetween measuring bowl and
24、cover assembly. The interiorsurfaces of the measuring bowl and surfaces of rims, flanges,and other component fitted parts shall be machined smooth.The measuring bowl and cover assembly shall be sufficientlyrigid to limit the expansion factor, D, of the apparatus assembly(Annex A1.5) to not more than
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC231C231M2010STANDARDTESTMETHODFORAIRCONTENTOFFRESHLYMIXEDCONCRETEBYTHEPRESSUREMETHOD 压力 测定 混凝土 空气

链接地址:http://www.mydoc123.com/p-466082.html