ASTM C151 C151M-2016 Standard Test Method for Autoclave Expansion of Hydraulic Cement《水硬水泥热压膨胀的标准试验方法》.pdf
《ASTM C151 C151M-2016 Standard Test Method for Autoclave Expansion of Hydraulic Cement《水硬水泥热压膨胀的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C151 C151M-2016 Standard Test Method for Autoclave Expansion of Hydraulic Cement《水硬水泥热压膨胀的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C151/C151M 15C151/C151M 16Standard Test Method forAutoclave Expansion of Hydraulic Cement1This standard is issued under the fixed designation C151/C151M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers determination of the autoclave expansion of hydraulic cement by means of a test on a neat cements
3、pecimen. a hardened cement paste when exposed to the autoclave conditions in this method.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independ
4、ently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and
5、 health practices and determine the applicability of regulatorylimitations prior to use. For specific precaution statements, see the section on Safety Precautions.2. Referenced Documents2.1 ASTM Standards:2C187 Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste
6、C305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic ConsistencyC490 Practice for Use of Apparatus for the Determination of Length Change of Hardened Cement Paste, Mortar, and ConcreteC511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage
7、 Tanks Used in the Testing of HydraulicCements and ConcretesC856 Practice for Petrographic Examination of Hardened ConcreteC1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing ofHydraulic CementsC1157 Performance Specification for Hydra
8、ulic Cement3. Significance and Use3.1 The autoclave expansion test provides an index of potential delayed expansion caused by the hydration of CaO or MgO,or both, when present in hydraulic cement.34. Interferences4.1 Pozzolans containing fine-grained quartz have been reported to cause excessive expa
9、nsion under autoclave test conditionsdue to alkali-silica reaction that will not occur under normal service conditions.4 When excessive expansion of paste containingpozzolans occurs, it is recommended that the specimens be examined (see Practice C856) for evidence of alkali-silica reaction(Note 1).N
10、OTE 1If the excessive expansion has resulted from alkali-silica reaction under autoclave conditions, the pozzolan can be evaluated for alkalireactivity using the procedure described in Performance Specification C1157.5. Apparatus5.1 Weighing Devices and Weights, for determining the mass of materials
11、 conforming to the requirements of SpecificationC1005.1 This test method is under the jurisdiction of ASTM Committee C01 on Cement and is the direct responsibility of Subcommittee C01.31 on Volume Change.Current edition approved Jan. 1, 2015Dec. 15, 2016. Published January 2015December 2016. Origina
12、lly approved in 1940. Last previous edition approved in 20092015as C151/C151M 09.C151/C151M 15. DOI: 10.1520/C0151_C0151M-15.10.1520/C0151_C0151M-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standa
13、rdsvolume information, refer to the standards Document Summary page on the ASTM website.3 Gonnerman, H. F., Lerch, W. and Whiteside, T. M., “Investigations of the Hydration Expansion Characteristics of Portland Cements,” Portland Cement AssociationResearch Department Bulletin 45, pp. 1168, 1953.4 Wa
14、ng, H., “Autoclave Soundness Test Mischaracterizes Cement-FlyAsh Blends by IntroducingAlkali-Quartz Reaction,” Cement, Concrete, and Aggregates, Vol 24, No.2, pp. 6872, 2002.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what chang
15、es have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the offici
16、al document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 Glass Graduates, 200 or 250-mL capacity, and conforming to the requirements of Practice C490.5.3 Molds, c
17、onforming to the requirements of Practice C490 for test specimens used in the determination of length change ofcement paste.5.4 Flat Trowel, conforming to the requirements of Test Method C187.5.5 Autoclave, consisting of a high-pressure steam vessel provided with a thermometer well. The autoclave sh
18、all be equippedwith automatic controls and either a rupture disk with a bursting pressure of 2.4 MPa 350 psi65 % or a safety valve that actuatesat this pressure. In addition, the autoclave shall be equipped with a vent valve to allow the escape of air during the early part ofthe heating period and t
19、o release any steam pressure remaining at the end of the cooling period. The pressure gauge shall have anominal capacity of 4.0 MPa 600 psi, a dial with a nominal diameter of 115 mm 412 in. and shall be graduated from 0 to 4.0MPa 0 to 600 psi with scale divisions not exceeding 0.03 MPa 5 psi. The er
20、ror in the gauge shall not exceed 6 0.02 MPa 63 psi at the operating pressure of 2 MPa 295 psi. The capacity of the heating unit shall be such that with maximum load (waterplus specimens) the pressure of the saturated steam in the autoclave may be raised to a gauge pressure of 2 MPa 295 psi in 45to
21、75 min from the time the heat is turned on. The automatic control shall be capable of maintaining the gauge pressure at 2 60.07 MPa 295 6 10 psi for at least 3 h. A gauge pressure of 2 6 0.07 MPa 295 6 10 psi corresponds to a temperature of 2166 2C 420 6 3F. The autoclave shall be designed to permit
22、 the gauge pressure to drop from 2 MPa to less than 0.07 MPa295 psi to less than 10 psi in 112 h after the heat supply has been shut off.5.5.1 Rupture DiskThe rupture disk shall be made of a material having a tensile strength that is relatively insensitive totemperature in the range 20 to 216C 68 to
23、 420F and that is electrochemically compatible with the pipe leading to it and to itsholder.55.6 Length ComparatorThe comparator used for measuring length change of specimens shall conform to the requirements ofPractice C490.6. Temperature and Humidity6.1 Molding RoomMaintain the temperature of the
24、molding room, dry materials and mixing water, and the relative humidityof the molding room within the limits of Practice C490.6.2 Moist Storage FacilitiesMaintain the temperature and humidity of the moist storage facilities to the requirements ofSpecification C511.7. Safety Precautions7.1 The pressu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC151C151M2016STANDARDTESTMETHODFORAUTOCLAVEEXPANSIONOFHYDRAULICCEMENT 水泥 热压 膨胀 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-464941.html