ASTM C1508-2001(2006) Standard Test Method for Determination of Bromine and Chlorine in UF6 and Uranyl Nitrate by X-Ray Fluorescence (XRF) Spectroscopy《用X射线荧光光谱测定法UF-6和硝酸铀酰中溴和氯的含量的.pdf
《ASTM C1508-2001(2006) Standard Test Method for Determination of Bromine and Chlorine in UF6 and Uranyl Nitrate by X-Ray Fluorescence (XRF) Spectroscopy《用X射线荧光光谱测定法UF-6和硝酸铀酰中溴和氯的含量的.pdf》由会员分享,可在线阅读,更多相关《ASTM C1508-2001(2006) Standard Test Method for Determination of Bromine and Chlorine in UF6 and Uranyl Nitrate by X-Ray Fluorescence (XRF) Spectroscopy《用X射线荧光光谱测定法UF-6和硝酸铀酰中溴和氯的含量的.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1508 01 (Reapproved 2006)Standard Test Method forDetermination of Bromine and Chlorine in UF6and UranylNitrate by X-Ray Fluorescence (XRF) Spectroscopy1This standard is issued under the fixed designation C 1508; the number immediately following the designation indicates the year ofori
2、ginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This method covers the determination of bromine (Br)and chlor
3、ine (Cl) in uranium hexafluoride (UF6) and uranylnitrate solution. The method as written covers the determina-tion of bromine in UF6over the concentration range of 0.2 to8 g/g, uranium basis. The chlorine in UF6can be determinedover the range of 4 to 160 g/g, uranium basis. Higherconcentrations may
4、be covered by appropriate dilutions. Thedetection limit for Br is 0.2 g/g uranium basis and for Cl is 4g/g uranium basis.1.2 This standard may involve hazardous materials, opera-tions and equipment. This standard does not purport to addressall of the safety concerns, if any, associated with its use.
5、 It isthe responsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 761 Test Methods for Chemical, Mass Spectrometric,Spectrochemical, Nuclear, and
6、 Radiochemical Analysis ofUranium HexafluorideC 787 Specification for Uranium Hexafluoride for Enrich-mentC 788 Specification for Nuclear-Grade Uranyl Nitrate So-lution or CrystalsC 1118 Guide for Selecting Components for Wavelength-Dispersive X-Ray Fluorescence (XRF) SystemsD 1193 Specification for
7、 Reagent Water3. Summary of Test Method3.1 A sample of hydrolyzed UF6(uranyl fluoride) or uranylnitrate solution is treated with sodium nitrite to reduce oxidizedforms of bromine and chlorine (bromates and chlorates) to theirrespective halide ions.Addition of silver nitrate precipitates thesilver ha
8、lides. Spike recoveries can be improved by theaddition of potassium iodide causing coprecipitation of thehalides. The halides are collected on filter paper and areanalyzed by X-ray fluorescence using two different crystal/detector systems.4. Significance and Use4.1 The method is designed to show whe
9、ther or not thetested materials meet the specifications as given in Specifica-tions C 787 and C 788.5. Interferences5.1 Plastic equipment must be used throughout the methodfor uranyl fluoride as the hydrofluoric acid in the uranylfluoride leaches chloride from glassware causing a high bias.5.2 Low r
10、ecoveries may occur as the precipitate can bedifficult to transfer quantitatively to the filter paper. A surfac-tant can be added (optional step) to minimize the adhesion ofthe precipitate to the walls of the beakers and the funnel.6. Apparatus6.1 X-Ray Spectrometer, see Guide C 1118 for the selecti
11、onof the X-ray Spectrometer.6.2 Plastic Vacuum Filtration Apparatus, for 47 mm diam-eter filter paper.6.3 Filter Paper, 0.45 micron, 47 mm diameter.36.4 Beakers, polypropylene, 250 mL.6.5 Stirring Rods, plastic or Teflon.6.6 X-ray Sample Support, Rings. Inner diameter approxi-mately 40 mm.7. Reagent
12、s7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society, where1This test method is under the jurisdiction of ASTM Commit
13、tee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee C26.05 on Methods ofTest.Current edition approved July 1, 2006. Published September 2006. Originallyapproved in 2001. Last previous edition approved in 2001 as C 150801.2For referenced ASTM standards, visit the ASTM websit
14、e, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The filter must be Cl and Br free. Millipore membrane filter type HABP() has been successfully used. An alternate
15、 is 15A from S.C.B,BP6, RN86, 07130 Soyons France. Any other equivalent is acceptable.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.such specifications are available.4Other grades may be used,provided it is first ascertained that t
16、he reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D 1193, Type I.7.3 Ammonium Hydroxide,NH4OH, concentrat
17、ed, specificgravity 0.90.7.4 Ammonium Hydroxide Solution, 1 + 3 (3.7 M). Dilute 1part NH4OH with 3 parts water.7.5 Surfactant, bromine and chlorine free.5(Optional).7.6 Surfactant Solution, 1 + 999. Add 1 mL of surfactant toapproximately 1 litre of water. (Optional).7.7 Nitric Acid, HNO3, concentrat
18、ed, specific gravity 1.42.7.8 Nitric Acid Solution, 1 + 999 (0.016 M). Add 1 mL ofconcentrated HNO3to approximately 200 mL of water. Add 1mL of the surfactant (7.6). (Optional). Dilute to 1 litre.7.9 Sodium Nitrite, NaNO2.7.10 Sodium Nitrite Solution, 2 g/L. Dissolve1gofsodiumnitrite in water and di
19、lute to 500 mL. Prepare fresh immedi-ately before use.7.11 Silver Nitrate, AgNO3.7.12 Silver Nitrate Solution, 2 g/L. Dissolve2gofsilvernitrate in water and dilute to 1 litre. Keep away from light in anopaque bottle. The solution should be made fresh weekly.Silver is an RCRA listed hazardous waste.
20、Make up only asmuch of this solution as required to minimize excess waste.7.13 Potassium Bromide, KBr.7.14 Bromide Solution, 500 mg Br/L. Dissolve 0.1861 g ofKBr (dried at 110C for 1 hour) in water and dilute to 250 mLin a volumetric flask.7.15 Sodium Chloride, NaCl.7.16 Sodium Chloride Solution, 10
21、00 mg Cl/L. Dissolve1.648 g NaCl (dried at 110 C for 1 hour ) in water and diluteto 1 litre in a volumetric flask.7.17 Spike Solution, 5 mg Br/L, 100 mg Cl/L. Transfer 10mL of 500 mg Br /L solution into a 1 litre volumetric flask bypipette. Transfer 100 mL of 1000 mg Cl /L into the flask bypipette.
22、Dilute to volume.7.18 Potassium Iodide, KI. (Optional).7.19 Potassium Iodide Solution, (Optional), 1g I/L. Dis-solve 0.131 g potassium iodide in water and dilute to 100 mL.The solution should be prepared weekly.8. Standard Preparation8.1 Pipette the following aliquots of spike solution (from7.17) in
23、to polypropylene beakers. 0 mL, 1 mL, 2 mL, 5 mL, 10mL. The aliquots represent 0g Br, 5g Br, 10g Br, 25g Br,50g Br and 0g Cl, 100g Cl, 200g Cl, 500g Cl, 1000g Cl.8.2 Add 70 mL water to each beaker.8.3 Follow steps 9.3-9.8 at the same time as the samples.9. Procedure9.1 Transfer a known aliquot of ur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC150820012006STANDARDTESTMETHODFORDETERMINATIONOFBROMINEANDCHLORINEINUF6ANDURANYLNITRATEBYXRAYFLUORESCENCEXRFSPECTROSCOPY

链接地址:http://www.mydoc123.com/p-464933.html