ASTM C1506-2009 Standard Test Method for Water Retention of Hydraulic Cement-Based Mortars and Plasters《基于灰浆和灰泥的水泥的水滞留性的标准试验方法》.pdf
《ASTM C1506-2009 Standard Test Method for Water Retention of Hydraulic Cement-Based Mortars and Plasters《基于灰浆和灰泥的水泥的水滞留性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1506-2009 Standard Test Method for Water Retention of Hydraulic Cement-Based Mortars and Plasters《基于灰浆和灰泥的水泥的水滞留性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1506 09Standard Test Method forWater Retention of Hydraulic Cement-Based Mortars andPlasters1This standard is issued under the fixed designation C1506; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method provides for the determination of waterretention of hydraulic cement-based mortars and plasters.1.2 The v
3、alues stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate
4、safety and health practices and determine the applica-bility of regulatory limitations prior to use. (WarningFreshhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.)22. Referenced Documents2.1 ASTM Standards:3C109/C109M Test Method for
5、 Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C185 Test Method for Air Content of Hydraulic CementMortarC230/C230M Specification for Flow Table for Use in Testsof Hydraulic CementC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plast
6、ic ConsistencyC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC1437 Test Method for Flow of Hydraulic Ceme
7、nt Mortar3. Summary of Test Method3.1 The flow of the mortar or plaster is determined. Themortar or plaster is then subjected to a controlled vacuumsuction for 60 s, after which the flow is again determined. Thewater retention is the final flow divided by the initial flowexpressed as a percentage.4.
8、 Significance and Use4.1 This test method provides a means for determining theability of mortars and plasters to retain water under suction.Test results may be used to determine compliance withspecifications.4.2 The results obtained using this test method can be usedto compare the relative ability o
9、f mortars and plasters to retainwater under suction.4.3 The results obtained using this test method for masonrymortars do not necessarily indicate the degree of waterretention when used with masonry units, since the amount ofwater absorbed by the unit depends on the rate of absorption ofthe masonry
10、unit.4.4 The results obtained using this test method for plasters(stucco) do not necessarily indicate the degree of waterretention when the plaster is applied as a second coat on thesurface of a previously applied plaster base coat, since theamount of water absorbed from the second coat of plasterde
11、pends on the rate of absorption of the base coat. This is alsotrue when a plaster is applied as a coating on masonry units.5. Apparatus5.1 Tamper, conforming to Test Method C109/C109M.5.2 Straightedge, conforming to Test Method C185.5.3 Flow Table, conforming to Specification C230/C230M.5.4 Mixing A
12、pparatus, conforming to the requirements pre-scribed in Practice C305.5.5 Filtration Assembly, an apparatus essentially as shownin Fig. 1 shall be used. This apparatus consists of a perforateddish resting on a funnel, which is connected by a three-waystopcock to a vacuum flask, to which a controlled
13、 vacuum isapplied. The perforated dish shall be made of metal notattacked by masonry mortar or plaster (Note 1). The metal baseof the dish shall have a thickness of 2.0 6 0.3 mm and shallconform to the requirements given in Fig. 1. The stopcock bore1This test method is under the jurisdiction of ASTM
14、 Committee C01 on Cementand is the direct responsibility of Subcommittee C01.22 on Workability.Current edition approved Dec. 1, 2009. Published January 2010. Originallyapproved in 2001. Last previous edition approved in 2008 as C150608. DOI:10.1520/C1506-09.2Section on Safety, Manual of Cement Testi
15、ng, Annual Book of ASTMStandards, Vol 04.01.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Ch
16、anges section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.shall have a 4.0 6 0.5-mm diameter, and the connecting glasstubing shall have a minimum inside diameter of 4 mm. Thelength of the tubing
17、 projecting into the 1-L flask from thestopcock shall extend at least 25 mm below the center line ofthe vacuum connection. The contact surfaces of the funnel andperforated dish shall be plane and may need to be lapped toensure intimate contact. An airtight seal shall be maintainedbetween the funnel
18、and the dish during the test. This shall beaccomplished by either of the following procedures. (1)Asynthetic (grease-resistant) rubber gasket may be permanentlysealed to the top of the funnel using petrolatum or light greaseto ensure a seal between the gasket and dish. (2) The top of theNOTEThe gask
19、et is to be synthetic rubber. The stopcock and the bore of the tubing shall be at least 4-mm. A check valve or water trap, or both, issuggested for the connection to the vacuum source.FIG. 1 Apparatus Assembly for the Water-Retention TestC1506 092funnel may be lightly coated with petroleum or light
20、grease toensure a seal between the funnel and dish. Care should be takento ensure that none of the holes in the perforated dish becomeclogged. Hardened, smooth, not rapid filter paper shall be used.It shall be 150 mm in diameter and be placed so as tocompletely cover the perforations in the dish.NOT
21、E 1Stainless steel, brass, and bronze are suitable metals for thispurpose.5.6 Controlled Vacuum Source:5.6.1 A vacuum gage capable of reading at least 9-kPapressure in 0.1-kPa increments (Note 2 and Note 3), connectedto a miniature vacuum regulator having a maximum 55-kPacapacity, which is then conn
22、ected to a vacuum pump or wateraspirator as shown in Fig. 1. Connection is made between thevacuum flask and the vacuum gage.NOTE 2Vacuum values are all given as pressure relative to atmo-spheric pressure.NOTE 3Gages reading pressure in other units are acceptable as longas their capacity and scale in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC15062009STANDARDTESTMETHODFORWATERRETENTIONOFHYDRAULICCEMENTBASEDMORTARSANDPLASTERS 基于 灰浆 灰泥 水泥

链接地址:http://www.mydoc123.com/p-464925.html