《ASTM C1363-2011 Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus《用高温实验室法测定建筑材料和包装组件热性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1363-2011 Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus《用高温实验室法测定建筑材料和包装组件热性能的标准试验方法》.pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1363 11Standard Test Method forThermal Performance of Building Materials and EnvelopeAssemblies by Means of a Hot Box Apparatus1This standard is issued under the fixed designation C1363; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method establishes the principles for the designof a hot box apparatus and the
3、 minimum requirements for thedetermination of the steady state thermal performance ofbuilding assemblies when exposed to controlled laboratoryconditions. This method is also used to measure the thermalperformance of a building material at standardized test condi-tions such as those required in mater
4、ial Specifications C739,C764, C1224 and Practice C1373.1.2 This test method is used for large homogeneous ornon-homogeneous specimens. This test method applies tobuilding structures or composite assemblies of building mate-rials for which it is possible to build a representative specimenthat fits th
5、e test apparatus. The dimensions of specimenprojections or recesses are controlled by the design of the hotbox apparatus. Some hot boxes are limited to planar or nearlyplanar specimens. However, larger hot boxes have been used tocharacterize projecting skylights and attic sections. See 3.2 fora defi
6、nition of the test specimen and other terms specific to thismethod.NOTE 1This test method replaces Test Methods C236, the GuardedHot Box, and C976, the Calibrated Hot Box which have been withdrawn.Test apparatus designed and operated previously under Test MethodsC236 and C976 will require slight mod
7、ifications to the calibration andoperational procedures to meet the requirements of Test Method C1363.21.3 A properly designed and operated hot box apparatus isdirectly analogous to the Test Method C177 guarded hot platefor testing large specimens exposed to air induced temperaturedifferences. The o
8、peration of a hot box apparatus requires asignificant number of fundamental measurements of tempera-tures, areas and power. The equipment performing thesemeasurements requires calibration to ensure that the data areaccurate. During initial setup and periodic verification testing,each measurement sys
9、tem and sensor is calibrated against astandard traceable to a national standards laboratory. If the hotbox apparatus has been designed, constructed and operated inthe ideal manner, no further calibration or adjustment would benecessary.As such, the hot box is considered a primary methodand the uncer
10、tainty of the result is analyzed by direct evalua-tion of the component measurement uncertainties of theinstrumentation used in making the measurements.1.3.1 In an ideal hotbox test of a homogenous material thereis no temperature difference on either the warm or coldspecimen faces to drive a flankin
11、g heat flow. In addition, therewould be no temperature differences that would drive heatacross the boundary of the metering chamber walls. However,experience has demonstrated that maintaining a perfect guard/metering chamber balance is not possible and small correctionsare needed to accurately chara
12、cterize all the heat flow pathsfrom the metering chamber. To gain this final confidence in thetest result, it is necessary to benchmark the overall result of thehot box apparatus by performing measurements on specimenshaving known heat transfer values and comparing those resultsto the expected value
13、s.1.3.2 The benchmarking specimens are homogeneous pan-els whose thermal properties are uniform and predictable.These panels, or representative sections of the panels, have hadtheir thermal performance measured on other devices that aredirectly traceable or have been favorably compared to anational
14、standards laboratory. For example, a Test MethodC177 Hot Plate, a Test Method C518 Heat Meter or anotherTest Method C1363 Hot Box will provide adequate specimens.Note that the use of Test Method C518 or similar apparatuscreates additional uncertainty since those devices are calibratedusing transfer
15、standards or standard reference materials. Byperforming this benchmarking process, the hot box operator isable to develop the additional equations that predict themagnitude of the corrections to the net heat flow through thespecimen that account for any hot box wall loss and flankingloss. This bench
16、marking provides substantial confidence thatany extraneous heat flows can be eliminated or quantified withsufficient accuracy to be a minor factor of the overall uncer-tainty.1.4 In order to ensure an acceptable level of result uncer-tainty, persons applying this test method must possess aknowledge
17、of the requirements of thermal measurements andtesting practice and of the practical application of heat transfer1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.30 on ThermalMeasurement.Current edition approve
18、d May 15, 2011. Published June 2010. Originallyapproved in 1997. Last previous edition approved in 2005 as C1363 05. DOI:10.1520/C1363-11.2Footnotes in the text are supplied to clarify the discussion only, and as such, arenot mandatory.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C70
19、0, West Conshohocken, PA 19428-2959, United States.theory relating to thermal insulation materials and systems.Detailed operating procedures, including design schematicsand electrical drawings, shall be available for each apparatus toensure that tests are in accordance with this test method.1.5 This
20、 test method is intended for use at conditions typicalof normal building applications. The naturally occurring out-side conditions in temperate zones range from approximately48 to 85C and the normal inside residential temperatures isapproximately 21C. Building materials used to construct thetest spe
21、cimens shall be pre-conditioned, if necessary, basedupon the materials properties and their potential variability.The preconditioning parameters shall be chosen to accuratelyreflect the test samples intended use and shall be documentedin the report. Practice C870 may be used as a guide for testspeci
22、men conditioning. The general principles of the hot boxmethod can be used to construct an apparatus to measure theheat flow through industrial systems at elevated temperatures.Detailed design of that type of apparatus is beyond the scope ofthis method.1.6 This test method permits operation under nat
23、ural orforced convective conditions at the specimen surfaces. Thedirection of airflow motion under forced convective conditionsshall be either perpendicular or parallel to the surface.1.7 The hot box apparatus also is used for measurements ofindividual building assemblies that are smaller than the m
24、eter-ing area. Special characterization procedures are required forthese tests. The general testing procedures for these cases aredescribed in Annex A11.1.8 Specific procedures for the thermal testing of fenestra-tion systems (windows, doors, skylights, curtain walls, etc.) aredescribed in Test Meth
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13632011STANDARDTESTMETHODFORTHERMALPERFORMANCEOFBUILDINGMATERIALSANDENVELOPEASSEMBLIESBYMEANSOFAHOTBOXAPPARATUS

链接地址:http://www.mydoc123.com/p-464360.html