ASTM C1139-1990(2002) Standard Specification for Fibrous Glass Thermal Insulation and Sound Absorbing Blanket and Board for Military Applications《军事用玻璃纤维绝热和隔音用覆盖层和板》.pdf
《ASTM C1139-1990(2002) Standard Specification for Fibrous Glass Thermal Insulation and Sound Absorbing Blanket and Board for Military Applications《军事用玻璃纤维绝热和隔音用覆盖层和板》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1139-1990(2002) Standard Specification for Fibrous Glass Thermal Insulation and Sound Absorbing Blanket and Board for Military Applications《军事用玻璃纤维绝热和隔音用覆盖层和板》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1139 90 (Reapproved 2002)Standard Specification forFibrous Glass Thermal Insulation and Sound AbsorbingBlanket and Board for Military Applications1This standard is issued under the fixed designation C 1139; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers unfaced flexible fibrous glassblanket an
3、d faced board used for thermal and sound absorbinginsulation at temperatures up to 450F (232C) for militaryapplications as a replacement for MIL-I-22023D.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 The follo
4、wing hazard caveat pertains only to the testmethod section of this specification. This standard does notpurport to address all of the safety concerns, if any, associatedwith its use. It is the responsibility of the user of this standardto establish appropriate safety and health practices anddetermin
5、e the applicability of regulatory limitations prior touse.2. Referenced Documents2.1 ASTM Standards:C 167 Test Methods for Thickness and Density of Blanketsor Batt Thermal Insulations2C 168 Terminology Relating to Thermal Insulation2C 177 Test Method for Steady-State Heat Flux Measure-ments and Ther
6、mal Transmission Properties by Means ofthe Guarded-Hot-Plate Apparatus2C 390 Criteria for Sampling and Acceptance of PreformedThermal Insulation Lots2C 411 Test Method for Hot-Surface Performance of HighTemperature Thermal Insulation2C 423 Test Method for Sound Absorption and Sound Ab-sorption Coeff
7、icients by the Reverberation Room Method2C 518 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Heat Flow Meter Apparatus2C 612 Specification for Mineral Fiber Block and BoardThermal Insulation2C 665 Specification for Mineral Fiber Blanket Therm
8、alInsulation for Light Frame Construction and ManufacturedHousing2C 1101/C1101M Test Method for Classifying the Flexibilityor Rigidity of Mineral Fiber Blanket and Board Insulation2E 84 Test Method for Surface Burning Characteristics ofBuilding Materials32.2 U.S. Military Standards:MIL-STD-167-1 Mec
9、hanical Vibrations of ShipboardEquipment (Type 1 Environmental and Type II InternallyExcited)4MIL-Y-1140 Yarn, Cord, Sleeving, Cloth and Tape-Glass4MIL-A-3316 Adhesives, Fire Resistant, Thermal Insula-tion43. Terminology3.1 DefinitionsTerminology C 168 shall apply to theterms used in this specificat
10、ion.4. Classification4.1 The fibrous glass felt shall be of the following types andgrades:Type I, Unfaced Thermal Blanket Nominal Density, lb/ft3(kg/m3)Grade 1 0.75 (12)Grade 2 1.00 (16)Grade 3 1.50 (24)Grade 4 2.00 (32)Grade 5 2.50 (40)Grade 6 3.00 (48)Type II, Unfaced Sound AbsorbingBlanket Nomina
11、l Density, lb/ft3(kg/m3)Grade 1 0.75 (12)Grade 2 1.00 (16)Grade 3 1.50 (24)Grade 4 2.00 (32)Grade 5 2.50 (40)Grade 6 3.00 (48)Type III, Faced, Thermal and SoundAbsorbing BoardDensity shall be 2.8 (45)lb/ft3(kg/m3)1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulatio
12、n and is the direct responsibility of Subcommittee C16.23 onBlanket and Loose Fill Insulation.Current edition approved Feb. 23, 1990. Published August 1990.2Annual Book of ASTM Standards, Vol 04.06.3Annual Book of ASTM Standards, Vol 04.07.4Available from Standardization Documents Order Desk, Bldg.
13、4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Ordering Information5.1 The type, dimensions, density, maximum use tempera-ture, and facing (if required) shall be specified
14、 by the pur-chaser. A product certification may be specified in the purchaseorder.6. Materials and Manufacture6.1 Composition:6.1.1 The insulation shall be composed of glass, processedfrom a molten state into a fibrous form, bonded with a chemicalbinder. Asbestos shall not be used as an ingredient o
15、r compo-nent part of the product.6.1.2 The facing shall be a polyester film reinforced withglass yarns (MIL-I-1140). The laminating adhesive shall con-form to the requirements of MIL-A-3316. Asbestos shall not beused as an ingredient or component part of the product.7. Physical Requirements7.1 A 1-i
16、n. (25-mm) thick sample of the insulation shall beflexible when tested in accordance with 11.1.7.2 The insulation shall be of the nominal density specifiedfor its grade with a tolerance of 610 %. Density shall bedetermined in accordance with 11.2.7.3 Maximum Temperature of UseWhen tested in accor-da
17、nce with 11.10 at the insulations maximum use temperatureof 450F (232C), the insulation shall not crack, warp, flame,glow, smolder, or show evidence of fused fibers.7.4 The nonfibrous material (shot) content shall not begreater than 1.5 % by weight when tested in accordance with11.3.7.5 Binder Conte
18、ntWhen tested in accordance with 11.4,the binder content shall not exceed 30 % by weight.7.6 Corrosiveness to SteelWhen tested in accordance with11.6, steel plates in contact with the insulation shall show nocorrosion greater than comparative plates in contact with sterilecotton.7.7 Surface Burning
19、Characteristics Type I and IITheinsulation shall have a flame spread index not greater than 25and a smoke developed index not greater than 50 when testedin accordance with Test Method E 84.7.8 Quarter Scale Room Fire Test of Type IIIType III shallmeet the requirements of the Quarter-Scale Room-Fire
20、TestMethod described in 11.12.7.9 Apparent Thermal ConductivityThe thermal conduc-tivities for Type I, Grade 1 through 6 and Type III materialsshall not exceed the values shown in Table 1. Thermalconductivity shall be determined by Test Methods C 177 orC 518.7.10 Vibration Resistance of Type II Mate
21、rialsThere shallbe a maximum of 0.50 % weight loss and the insulation shallnot settle and lose thickness when subjected to the vibrationtest described in 11.9.7.11 Acoustical Performance of Type II MaterialsThecoefficients of absorption shall be not less than those shown inTable 2 when Type II mater
22、ial is tested in accordance with11.8.7.12 KerfingType III panels shall be capable of beingkerfed with a 90 V-groove to facilitate bending when the panelis folded to a right angle. The facing material shall be flexibleto form a neat square corner at the kerfed joint (see 11.11).7.13 Flashover TimeFla
23、shover time shall not occur within10 min when tested in accordance with 11.12.4.5.8. Dimensions and Permissible Variations8.1 The standard sizes and tolerances of Types I, II, and IIImaterials are listed in Table 3.9. Workmanship, Finish, and Appearance9.1 The insulation units shall indicate good wo
24、rkmanshipand shall not have defects that adversely affect their installationand service qualities.10. Sampling10.1 Inspection and qualification shall be in accordancewith Criteria C390. Other provisions for sampling can beagreed upon between the purchaser, seller, and manufacturer.11. Test Methods11
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC113919902002STANDARDSPECIFICATIONFORFIBROUSGLASSTHERMALINSULATIONANDSOUNDABSORBINGBLANKETANDBOARDFORMILITARYAPPLICATIONS

链接地址:http://www.mydoc123.com/p-463507.html