ASTM A388 A388M-2016 Standard Practice for Ultrasonic Examination of Steel Forgings《钢锻件超声波检测标准实施规程》.pdf
《ASTM A388 A388M-2016 Standard Practice for Ultrasonic Examination of Steel Forgings《钢锻件超声波检测标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM A388 A388M-2016 Standard Practice for Ultrasonic Examination of Steel Forgings《钢锻件超声波检测标准实施规程》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: A388/A388M 15A388/A388M 16 Used in USNRC-RDT standardsStandard Practice forUltrasonic Examination of Steel Forgings1This standard is issued under the fixed designation A388/A388M; the number immediately following the designation indicates the yearof original adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice2 covers the examination procedures for the contact, pulse-echo ultrasonic examina
3、tion of steel forgings by thestraight and angle-beam techniques. The straight beam techniques include utilization of the DGS (Distance Gain-Size) method. SeeAppendix X3.1.2 This practice is to be used whenever the inquiry, contract, order, or specification states that forgings are to be subject toul
4、trasonic examination in accordance with Practice A388/A388M.1.3 Supplementary requirements of an optional nature are provided for use at the option of the purchaser. The supplementaryrequirements shall apply only when specified individually by the purchaser in the purchase order or contract.1.4 The
5、values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the s
6、tandard.1.5 This specification and the applicable material specifications are expressed in both inch-pound units and SI units. However,unless the order specifies the applicable “M” specification designation SI units, the material shall be furnished to inch-poundunits.1.6 This standard does not purpo
7、rt to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:3A469/A
8、469M Specification for Vacuum-Treated Steel Forgings for Generator RotorsA745/A745M Practice for Ultrasonic Examination of Austenitic Steel ForgingsA788/A788M Specification for Steel Forgings, General RequirementsE317 Practice for Evaluating Performance Characteristics of Ultrasonic Pulse-EchoTestin
9、g Instruments and Systems without theUse of Electronic Measurement InstrumentsE428 Practice for Fabrication and Control of Metal, Other than Aluminum, Reference Blocks Used in Ultrasonic TestingE1065/E1065M Practice for Evaluating Characteristics of Ultrasonic Search Units2.2 Other Document: 4Recomm
10、ended Practice for Nondestructive Personnel Qualification and Certification SNT-TC-1A, (1988 or later)3. Terminology3.1 Definitions:3.1.1 indication levels (clusters), nfive or more indications in a volume representing a 2-in. 50-mm or smaller cube in theforging.1 This practice is under the jurisdic
11、tion of ASTM Committee A01 on Steel, Stainless Steel and Related Alloys and is the direct responsibility of Subcommittee A01.06on Steel Forgings and Billets.Current edition approved July 15, 2015May 1, 2016. Published July 2015May 2016. Originally approved in 1955. Last previous edition approved in
12、20112015 asA388/A388M 11.A388/A388M 15. DOI: 10.1520/A0388_A0388M-15.10.1520/A0388_A0388M-16.2 For ASME Boiler and Pressure Vessel Code applications see related Specification SA-388/SA-388M in Section II of that Code.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM
13、 Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.4 Available from American Society for Nondestructive Testing (ASNT), P.O. Box 28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt
14、.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prio
15、r editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1942
16、8-2959. United States13.1.2 individual indications, nsingle indications showing a decrease in amplitude as the search unit is moved in any directionfrom the position of maximum amplitude and which are too small to be considered traveling or planar.3.1.3 planar indications, nindications shall be cons
17、idered continuous over a plane if they have a major axis greater than 1 in.25 mm or twice the major dimension of the transducer, whichever is greater, and do not travel.3.1.4 traveling indications, ninductions whose leading edge moves a distance equivalent to 1 in. 25 mm or more of metaldepth with m
18、ovement of the transducer over the surface of the forging.4. Significance and Use4.1 This practice shall be used when ultrasonic inspection is required by the order or specification for inspection purposes wherethe acceptance of the forging is based on limitations of the number, amplitude, or locati
19、on of discontinuities, or a combinationthereof, which give rise to ultrasonic indications.4.2 The ultrasonic quality level shall be clearly stated as order requirements.5. Ordering Information5.1 When this practice is to be applied to an inquiry, contract, or order, the purchaser shall so state and
20、shall also furnish thefollowing information:5.1.1 Designation number (including year date),5.1.2 Method of establishing the sensitivity in accordance with 9.2.2 and 9.3.3 (Vee- (DGS (Distance Gain Size), Vee- orrectangular-notch),5.1.2.1 The diameter and test metal distance of the flat-bottom hole a
21、nd the material of the reference block in accordance with9.2.2.2,5.1.3 Quality level for the entire forging or portions thereof in accordance with 12.3, and5.1.4 Any options in accordance with 1.5, 6.4, 6.5, 7.1, 8.1, 8.2, 9.1.11, 10.1, 10.2, and 12.2.6. Apparatus6.1 Electronic ApparatusAn ultrasoni
22、c, pulsed, reflection type of instrument shall be used for this examination. The systemshall have a minimum capability for examining at frequencies from 1 to 5 MHz. On examining austenitic stainless forgings thesystem shall have the capabilities for examining at frequencies down to 0.4 MHz.6.1.1 App
23、aratus Qualification and CalibrationBasic qualification of the ultrasonic test instrument shall be performed atintervals not to exceed 12 months or whenever maintenance is performed that affects the equipment function. The date of the lastcalibration and the date of the next required calibration sha
24、ll be displayed on the test equipment.6.1.2 The ultrasonic instrument shall provide linear presentation (within 5 %) for at least 75 % of the screen height (sweep lineto top of screen). The 5 % linearity referred to is descriptive of the screen presentation of amplitude. Instrument linearity shall b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA388A388M2016STANDARDPRACTICEFORULTRASONICEXAMINATIONOFSTEELFORGINGS 锻件 超声波 检测 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-458230.html