1、 ANSI/FCI 79-1-2009 AMERICAN NATIONAL STANDARD STANDARD FOR PROOF OF PRESSURE RATINGS FOR PRESSURE REGULATORS ANSI/FCI 79-1 Fluid Controls Institute, Inc. Sponsor: Fluid Controls Institute, Inc. 1300 Sumner Ave Cleveland, Ohio 44115-2851ANSI/FCI 79-1-2009 AMERICAN NATIONAL STANDARD Standard for Proo
2、f of Pressure Ratings for Pressure Regulators Sponsor Fluid Controls Institute, Inc. iiCONTENTS PAGE Foreword .iv 1. Scope 1 2. Definitions .1 3. General .1 4. Test Procedure .2-4 5. Marking 4 iiiivForeword (The foreword and history are included for information purposes). This Fluid Controls Institu
3、tes (FCI) voluntary standard establishes guidelines for proof-of-design testing of pressure regulators used in the fluid controls industry. It is not intended for use in the routine production testing of regulators shells, which is covered by ANSI / FCI 4-1. This voluntary standard was developed as
4、a cooperative effort of the manufacturers in the Regulator Section of the FCI to assist manufacturers, users and specifiers of pressure regulators. This standard is not intended to supersede existing standards for regulators for specific applications such as those for gas appliance pressure regulato
5、rs, for high pressure regulators for gas cylinders, or for fluid power regulators in machinery operations. See FCI 86-2 for definitions of regulator types. This standard was originally adopted as an FCI standard May 16, 1979. The standard has been periodically revised and the latest revision was app
6、roved in July, 2003. FCI recognizes the need to periodically review and update this standard. Suggestions for improvement should be forwarded to the Fluid Controls Institute, Inc., 1300 Sumner Avenue, Cleveland, Ohio, 44115-2851. All constructive suggestions for expansion and revision of this standa
7、rd are welcome. The existence of a Fluid Controls Institute (FCI) standard does not in any respect preclude any member or non-member from manufacturing or selling products not conforming to this standard nor is the FCI responsible for its use. ANSI/FCI 79-1-2009 AMERICAN NATIONAL STANDARD Standard f
8、or Proof of Pressure Rating for Pressure Regulators1. SCOPE 1.1 This standard describes the recommended proof testing of pressure regulators for operation at or below the manufacturers rated pressure. 1.2 The purpose of this standard is to create common guidelines for establishing pressure ratings f
9、or use by manufacturers, users, specifiers and approval bodies in order to provide consistent pressure containment integrity. 2. DEFINITIONS 2.1 A pressure regulator as covered by this standard is a self contained and powered device that serves to automatically maintain a pressure at a controlled va
10、lue. 2.2 Specified minimum tensile strength is that called for in the material specification or the users order. 2.3 The test specimen is a sample taken from the same heat of a pressure retaining component. 2.4 The tensile ratio is the actual tensile strength of the specimen divided by the specified
11、 minimum tensile strength. 2.5 A rupture is the fracture of the pressure boundary, whether leading to a release of pressure in the chamber or not. 2.6 The wall thickness ratio is the actual wall thickness of the test specimen divided by the minimum allowable wall thickness of the test specimen in th
12、e area associated with measured displacement resulting from the hydraulic proof test. 2.7 Rated pressures as established by this standard are those which are specified by the manufacturer based on using the method of 4.5 or 4.10 and can safely be used in normal service without rupture of pressure co
13、ntaining parts, provided the regulators are installed as specified in 3.2. 3. GENERAL 3.1 This standard is limited to proof-of-design testing. It is not intended to cover the testing of duplicate parts of the same materials, designs and construction once a representative single unit has been tested
14、and a pressure rating established by the means specified herein. Some tests are potentially destructive and the regulator under test is not required to be functional after all tests are completed. 3.2 This standard includes pressure regulators which may have two static pressure ratings, one for the
15、portion of the regulator subjected to the inlet pressure and the other for the portion subjected to the outlet pressure. Such regulators should be installed with adequate over-pressure protection equipment to prevent excessive downstream pressure resulting from any system failure. 23.3 The ratings e
16、stablished by this standard are applicable to normal ambient temperatures, 38 to 100F (3 to 38C). Ratings at other temperatures for materials other than cast iron can be calculated by multiplying the test rating by the ratio of allowable stress at operating temperature to the allowable stress at rat
17、ing temperature. Rating of cast iron at elevated temperature shall be determined by provision of ASME B16.1. 3.4 Production units manufactured and rated to be in compliance with this standard shall have the same material multiplier (per Section 4.5) and pressure boundary geometry, independent of end
18、 connections, as the regulator which was tested and rated according to this standard. 3.5 The maximum pressures which can be sustained without damage to the internal parts are not covered in this standard. 3.6 The regulator end connections shall be considered in the overall determination of the pres
19、sure rating. The lesser value of the maximum allowable pressure of the end connection or body rating shall be used. 4. TEST PROCEDURE 4.1 In devices with dual pressure ratings, the valve plug or closure member in the test unit may be replaced with a member designed to isolate the chambers normally s
20、ubjected to inlet pressure from those normally subjected to outlet pressure. 4.2 Exhaust or vent holes may be plugged to conduct a pressure test. 4.3 A flexible part such as a diaphragm, bellows or similar item which cannot perform its function if subjected to proof test pressures as described in 4.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIFCI7912009STANDARDFORPROOFOFPRESSURERATINGSFORPRESSUREREGULATORS 压力 调节器 额定值 验证 标准 PDF

链接地址:http://www.mydoc123.com/p-434780.html