ANSI ASME A112.6.4-2003 ROOF DECK AND BALCONY DRAINS《房顶、地面和阳台排水管》.pdf
《ANSI ASME A112.6.4-2003 ROOF DECK AND BALCONY DRAINS《房顶、地面和阳台排水管》.pdf》由会员分享,可在线阅读,更多相关《ANSI ASME A112.6.4-2003 ROOF DECK AND BALCONY DRAINS《房顶、地面和阳台排水管》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、ASME A112.6.4-2003ROOF, DECK, AND BALCONYDRAINSAN AMERICAN NATIONAL STANDARDIntentionally left blank AN AMERICAN NATIONAL STANDARDROOF, DECK,AND BALCONYDRAINSASME A112.6.4-2003Date of Issuance: November 21, 2003The next edition of this Standard is scheduled for publication in 2008. There will be no
2、addenda orwritten interpretations of the requirements of this Standard issued to this edition.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria for American NationalStandards. The S
3、tandards Committee that approved the code or standard was balanced to assure that individuals fromcompetent and concerned interests have had an opportunity to participate. The proposed code or standard was madeavailableforpublicreviewandcommentthatprovidesanopportunityforadditionalpublicinputfromind
4、ustry,academia,regulatory agencies, and the public-at-large.ASME does not “approve,” “rate,” or “endorse” any item, construction, proprietary device, or activity.ASME does not take any position with respect to the validity of any patent rights asserted in connection with anyitems mentioned in this d
5、ocument, and does not undertake to insure anyone utilizing a standard against liability forinfringement of any applicable letters patent, nor assumes any such liability. Users of a code or standard are expresslyadvised that determination of the validity of any such patent rights, and the risk of inf
6、ringement of such rights, isentirely their own responsibility.Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpreted asgovernment or industry endorsement of this code or standard.ASME accepts responsibility for only those interpretations of t
7、his document issued in accordance with the establishedASME procedures and policies, which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without the prior written permission of the publish
8、er.The American Society of Mechanical EngineersThree Park Avenue, New York, NY 10016-5990Copyright 2003 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.CONTENTSForeword ivCommitteeRoster . vCorrespondenceWiththeA112Committee . vi1 General 12 Outlet Types and Outlet
9、Connections 23 Dimensional Criteria 44 Top Loading: Classification 55 Materials and Finishes 66 Accessories 77 Testing 88 Markings 8Figures1 GeneralPurposeRoofDrain . 32 GutterorCorniceRoofDrain 33 ParapetRoofDrain 34 RoofDrainWithOverflowandFlashingFlange 45 PromenadeorDeckRoofDrain 46 BottomOutlet
10、 . 57 SideOutlet 58 45DegSideOutlet. 59 AccessoriesforDrains . 8Tables1 MinimumDimensionsforThreadedOutletConnections 52 MinimumDimensionsforInsideCaulk(Gasket)OutletConnections 53 MinimumDimensionsforHubbed(Push-On)OutletConnections . 64 GeneralPurposeRoofDrain . 65 GutterorCorniceRoofDrain 66 Para
11、petRoofDrain 67 PromenadeorDeckRoofDrain 6iiiFOREWORDTheAmericanNationalStandardsCommitteeA112wasestablishedonJuly27,1955tostandard-izeplumbingmaterialsandequipment.ItsfirstorganizationalmeetingwasheldonJuly22,1958.Panel No. 21 was created on May 1, 1964, to establish standards for roof drains, floo
12、r drains,backwatervalves,andotherdrainagespecialties.Itsscopewastherecommendationofsuitableexistingstandardsincooperationwithinterestedsponsors,orthedevelopmentofadequatenewstandardsasneededforroofdrains,floordrains,andotherdrainsasusedorinstalledinplumbingsystems.Thecommitteehassincebeenreorganized
13、asanASMEStandardsCommittee.The ASME A112 Committee was restructured during 1998 in accordance with the ASMERedesignProcessandPanel21WorkingGroup1becameProjectTeam6.4.Theprojectteammettwice to update this Standard and incorporated criteria from the International Association ofPlumbingandMechanicalOff
14、icialsProductStandardsPS41andPS47.ThisStandardwasprecededbyANSIA112.21.2M-1983,whichwaswithdrawnin1995.Suggestions for the improvement of this Standard are welcome. They should be sent to theAmericanSocietyofMechanicalEngineers,ThreeParkAvenue,NewYork,NY10016-0509.ThisStandardwasapprovedasanAmerican
15、NationalStandardonAugust14,2003.ivASME A112 STANDARDS COMMITTEEStandardization of PlumbingMaterials and Equipment(The following is the roster of the Committee at the time of approval of this Standard.)OFFICERSP. J. Higgins, ChairS. A. Remedios, Vice ChairC. J. Gomez, SecretaryCOMMITTEE PERSONNELR. H
16、. Ackroyd, ConsultantJ. A. Ballanco, JB Engineering and Code ConsultingS. L. Cavanaugh, United AssociationA. Cohen, A. Cohen and AssociatesN. Covino, Alternate, American Standard, Inc.P. V. DeMarco, American Standard, Inc.G. S. Duren, Code Compliance, Inc.R. Emmerson, Chicago Faucets Co.F. C. Evans,
17、 Zin-Plas Corp.L. S. Galowin, National Institute of Standards and TechnologyC. J. Gomez, The American Society of Mechanical EngineersR. I. Greenwald, Sunroc Corp.G. Gress, BOCA InternationalJ. P. Gronewold, NSF InternationalP. J. Higgins, PJ Higgins and Associates, Inc.A112 PROJECT TEAM 6.4 ROOF DRA
18、INSS. J. McDanal, Project Team Leader, Jay R. Smith Manufacturing Co.R. H. Ackroyd, Deputy Project Team Leader, ConsultantA. R. Becker, Zurn Industries, Inc.G. J. Flegel, Flegel Consulting ServicesR. L. George, SmithGroup, Inc., Architects, EngineersC. R. Graham, Martech EnterprisesvD. E. Holloway,
19、SGS US Testing Co.M. Klimboff, ConsultantM. T. Kobel, IAPMOL. M. Kriegbaum, Alternate, Underwriters Laboratories, Inc.J. W. Lauer, Sloan Valve Co.R. M. Martin, California Energy CommissionP. Meikle, Underwriters Laboratories, Inc.L. E. Mercer, Moen, Inc.S. Rawalpindiwala, Kohler Co.S. A. Remedios, D
20、elta Faucet Co.J. A. Sargent, Alternate, Kohler Co.G. L. Simmons, Charlotte Pipe and FoundryW. M. Smith, Jay R. Smith Manufacturing Co.D. W. Viola, Plumbing Manufacturers InstituteR. E. White, Richard E. White and AssociatesW. C. Whitehead, Plumbing and Drainage InstituteP. J. Higgins, PJ Higgins an
21、d Associates, Inc.M. T. Kobel, IAPMOP. Szczotka, LSP Products Group Co.D. W. Viola, Plumbing Manufacturers InstituteR. E. White, Richard E. White and AssociatesW. C. Whitehead, Plumbing and Drainage InstituteCORRESPONDENCE WITH THE A112 COMMITTEEGeneral. ASMEStandardsaredevelopedandmaintainedwiththe
22、intenttorepresenttheconsensusofconcernedinterests.Assuch,usersofthisStandardmayinteractwiththeCommittee by requesting interpretations, proposing revisions, and attending Committeemeetings.Correspondenceshouldbeaddressedto:Secretary,A112StandardsCommitteeTheAmericanSocietyofMechanicalEngineersThreePa
23、rkAvenueNewYork,NY10016-5990Proposing Revisions. RevisionsaremadeperiodicallytotheStandardtoincorporatechangesthatappearnecessaryordesirable,asdemonstratedbytheexperiencegainedfromtheapplicationoftheStandard.Approvedrevisionswillbepublishedperiodically.TheCommitteewelcomesproposalsforrevisionstothis
24、Standard.Suchproposalsshouldbeasspecificaspossible,citingtheedition,theparagraphnumber(s),theproposedwording,andadetaileddescriptionofthereasonsfortheproposal,includinganypertinentdocumen-tation.Whenappropriate,proposalsshouldbesubmittedusingtheA112ProjectInitiationRequestForm.Interpretations. Upon
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASMEA112642003ROOFDECKANDBALCONYDRAINS 房顶 地面 阳台 排水管 PDF

链接地址:http://www.mydoc123.com/p-431646.html