ANSI AGA B109.4-2016 Self-Operated Diaphragm-Type Natural Gas Service Regulators For Nominal Pipe Size 1 inches (32 mm) and smaller with outlet pressures of 2 psig (13.8 kPa) and l.pdf
《ANSI AGA B109.4-2016 Self-Operated Diaphragm-Type Natural Gas Service Regulators For Nominal Pipe Size 1 inches (32 mm) and smaller with outlet pressures of 2 psig (13.8 kPa) and l.pdf》由会员分享,可在线阅读,更多相关《ANSI AGA B109.4-2016 Self-Operated Diaphragm-Type Natural Gas Service Regulators For Nominal Pipe Size 1 inches (32 mm) and smaller with outlet pressures of 2 psig (13.8 kPa) and l.pdf(39页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI B109.4 Approved Revised December 2016 Self-Operated Diaphragm-Type Natural Gas Service Regulators For Nominal Pipe Size 1 inches (32 mm) and smaller with outlet pressures of 2 psig (13.8 kPa) and less Secretariat 400 North Capitol Street, NW 4thFloor Washington, DC 20001 U.S.A. Catalog No. XM1
2、602 First Edition1998 Second Edition2016 Copyright 2016, American Gas Association All rights reservedi Table of Contents TABLE OF CONTENTS i DISCLAIMERS AND COPYRIGHT . ii PREFACE iv HISTORY OF DEVELOPMENT OF THE STANDARD v ACCREDITED STANDARDS COMMITTEE B109 . vi 1.0 Scope . 1 2.0 Definitions . 2 3
3、.0 General . 5 4.0 Design Requirements . 6 4.1 Regulator Valve Body . 6 4.2 Diaphragm Casing Assembly 7 4.3 Diaphragm . 8 4.4 Loading Spring 8 4.5 Valve Linkage and Disk 8 4.6 Orifice 9 4.7 Exterior Surface . 9 4.8 Vent . 10 4.9 Markings 11 5.0 Qualification Test for Service Regulator Performance 12
4、 5.1 General . 12 5.2 Test Equipment 13 5.3 Test Procedures 13 APPENDIX A: GUIDELINES FOR PRESENTATION OF REGULATOR PERFORMANCE DATA 24 APPENDIX B: SI/METRIC SYMBOLS 28 APPENDIX C: U.S. (INCH-POUND) SYMBOLS 29 APPENDIX D: REFERENCED STANDARDS 30 FORM FOR PROPOSALS ON ANSI B109.4 . 31 ii AMERICAN GAS
5、 ASSOCIATION (AGA) NOTICE AND DISCLAIMER This document was developed through a voluntary consensus standards development process via the American National Standards Institute (ANSI) essential requirements for due process for American National Standards (Edition January 2014). While the American Gas
6、Association (AGA) administers the process and establishes rules to promote fairness in the development of consensus, it does not write the document, and it does not independently test, evaluate or verify the accuracy or completeness of any information or the soundness of any judgments contained in t
7、his publication. The AGA disclaims liability for any personal injury, property damages or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from this publication, the use of or reliance on this publication. The AGA also
8、 makes no guarantee or warranty as to the accuracy or completeness of any information published herein. In issuing and making this document available, the AGA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the AGA undertaking to perform a
9、ny duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. The AGA has no power, nor doe
10、s it undertake, to police or enforce compliance with the contents of this document. Nor does the AGA list, certify, test or inspect products, designs or installations for compliance with this document. Any certification or other statement of compliance with the requirements of this document shall no
11、t be attributable to the AGA and is solely the responsibility of the certifier or maker of the statement. The AGA does not take any position with respect to the validity of any patent rights asserted in connection with any items that are mentioned in or are the subject of this publication, and the A
12、GA disclaims liability for the infringement of any patent resulting from the use of or reliance on it. Users of this publication are expressly advised that determination of the validity of any such patent rights and the risk of infringement of such rights is entirely their own responsibility. Users
13、of this publication should consult applicable federal, state, and local laws and regulations. The AGA does not, through this publication, provide legal advice for any purpose or intend to urge action that is not in compliance with applicable laws and this publication may not be construed as doing so
14、. Changes to this document may become necessary from time to time. If changes are believed appropriate by any person or entity, such suggested changes should be communicated to AGA in writing using the form found at the end of the document titled, Form For Proposals on ANSI B109.4 and sent to: Ameri
15、can Gas Association, ATTN: Secretariat B109, 400 North Capitol Street, NW, Suite 450, Washington, DC 20001, U.S.A. Suggested changes must include: contact information, including name, address and any corporate affiliation; full name of the document; suggested revisions to the text of the document; t
16、he rationale for the suggested revisions; and permission to use the suggested revisions in an amended publication of the document. iii Copyright 2016 American Gas Association, All Rights Reserved. Permission is granted to republish material herein in laws or ordinances as well as regulations, admini
17、strative orders or similar documents issued by public authorities. Those desiring permission for other publication should consult the American Gas Association, ATTN: ANSI B109.4 Secretariat, 400 N. Capitol St., NW, Washington, DC, U.S.A. iv PREFACE This publication presents a basic standard for the
18、safe and reliable operation and the substantial and durable construction of self-operated diaphragm-type natural gas service regulators for nominal pipe size of 1 inches (32 mm) and smaller with outlet pressure of 2 psig (3.48 kPa) and less. This work is the result of years of experience that has be
19、en supplemented by extensive research. The standard is intended to meet the minimum design, material, performance and testing requirements for efficient use of service regulators. It is recognized that during any transition period to the metric system, sizes and dimensions need to be expressed in ei
20、ther the metric system or the inch-pound system or both. In this document, both systems are used with the inch-pound units given preference. In most cases, a soft conversion from existing inch-pound values is shown. Soft conversion implies a change in nomenclature only. In this document, the alterna
21、tive nomenclatures (metric and inch-pound) are shown by using parentheses and can be used interchangeably. Nothing in this standard is to be considered as in any way indicating a measure of quality beyond compliance with the provisions it contains. It is designed to allow the construction and perfor
22、mance of service regulators that may exceed the various provisions specified in any respect. In this standards preparation, recognition was intended to be given to the possibility of improvement, through the ingenuity of design or otherwise. As progress takes place, revisions may become necessary. W
23、henever such revisions are believed desirable, recommendations should be forwarded to the Chairman of ANSI B109 Committee, American Gas Association, 400 N. Capitol St., NW, Washington, DC 20001 Users of this document should consult applicable federal, state and local regulations. The AGA does not, b
24、y the publication of this document, intend to present specifications that are not in compliance with applicable rules, and this document may not be construed as doing so. NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standard
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAGAB10942016SELFOPERATEDDIAPHRAGMTYPENATURALGASSERVICEREGULATORSFORNOMINALPIPESIZE1INCHES32MMANDSMALLERWITHOUTLETPRESSURESOF2PSIG138KPAANDLPDF

链接地址:http://www.mydoc123.com/p-430506.html