《IEEE C37 41 ERTA-2009 en Errata to IEEE Standard Design Tests for High-Voltage ( 1000 V) Fuses Fuse and Disconnecting Cutouts Distribution Enclosed Single-Pole .pdf》由会员分享,可在线阅读,更多相关《IEEE C37 41 ERTA-2009 en Errata to IEEE Standard Design Tests for High-Voltage ( 1000 V) Fuses Fuse and Disconnecting Cutouts Distribution Enclosed Single-Pole .pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、22 May 2009 1 STD95852 IEEE Std C37.41-2008 (Revision of IEEE Std C37.41-2000) Errata to IEEE Standard Design Tests for High-Voltage (1000 V) Fuses, Fuse and Disconnecting Cutouts, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Fuse Links and Accessories Used with T
2、hese Devices Sponsor Switchgear Committee of the IEEE Power see 6.2. f A fuse cutout support fuse base shall be capable, at a minimum, of the number of tests listed as “Number of tests required on each fuseholder and its fuse support.” For test series 1, this represents three tests with the minimum
3、fuse link rating using one fuseholder and support, and three tests with the maximum fuse link rating using another fuseholder and support. The same quantities would be used for test series 2, whereas for test series 3, one fuse holder and its support would be used for the two required tests. For tes
4、t series 4 and 5, the same fuseholder and support is used for the four required tests. Only the manufacturer has the discretion to permit a fuseholder, or cutout support to be used for more than the specified number of individual tests. After each test on a fuseholder that uses replaceable links, on
5、ly the fuse link and the expendable cap, if used, may be replaced. Only the manufacturer has the discretion to use an expendable cap for more than one test if it is determined that the cap was not damaged during a previous test. If the fuse element is an integral part of the fuseholder, then the num
6、ber of fuseholders to be tested is the number listed for “Number of tests required on each fuseholder and fuse support.” The mounting brackets used for the cutout testing should be as specified in ANSI C37.42. Any deviation from this specification shall be noted in the test report for the device. 22
7、 May 2009 3 STD95852 Table 8Interrupting performance tests and test circuit parameters for slant-voltage-rated (multiple-voltage-rated) distribution class fuse cutouts Parameters Test series 1 2 3 4 5 6aPower-frequency recovery voltage Rated maximum voltage to the left of the slant +5%, 0% Rated max
8、imum voltage to the right of the slant +5%, 0% Transient recovery voltage (TRV) See Table 9, column 1 See Table 9, column 2 See Table 9, column 4 See Noteb See Table 9, column 2 Prospective or test current rms symmetrical Rated interrupting current +5%, 0% From 70% to 80% rated interrupting current
9、From 20% to 30% rated interrupting currentc From 400 A to 500 AdFrom 2.7 to 3.3 times fuse link ratingeRated interrupting current +5%, 0% X/R ratio (power factor) See Table 10 From 1.3 to 0.75 (from 0.6 to 0.8) See Table 10 Making angle related to voltage zerodegrees 1st test: from 5 to +15 2nd test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC3741ERTA2009ENERRATATOIEEESTANDARDDESIGNTESTSFORHIGHVOLTAGE1000VFUSESFUSEANDDISCONNECTINGCUTOUTSDISTRIBUTIONENCLOSEDSINGLEPOLEPDF

链接地址:http://www.mydoc123.com/p-1249111.html