SSPC PA GUIDE 9-2008 Measurement of Dry Coating Thickness on Cementitious Substrates Using Ultrasonic Gages《使用超声波测量计对胶结基板上的干涂层厚度进行测量》.pdf
《SSPC PA GUIDE 9-2008 Measurement of Dry Coating Thickness on Cementitious Substrates Using Ultrasonic Gages《使用超声波测量计对胶结基板上的干涂层厚度进行测量》.pdf》由会员分享,可在线阅读,更多相关《SSPC PA GUIDE 9-2008 Measurement of Dry Coating Thickness on Cementitious Substrates Using Ultrasonic Gages《使用超声波测量计对胶结基板上的干涂层厚度进行测量》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、SSPC-PA 9February 1, 20081SSPC: The Society for Protective CoatingsPainT aPPLiCaTiOn SPECiFiCaTiOn nO. 9Measurement of Dry Coating Thickness on Cementitious Substrates Using Ultrasonic Gages1. Scope1.1 This standard describes procedures to measure the thickness of dry, homogeneous coatings applied o
2、n cementi-tious surfaces using commercially available ultrasonic coating thickness gages. These procedures are intended to supplement manufacturers operating instructions for the manual operation of the gages and are not intended to replace them.1.2 The procedures for calibration, adjustment, and ge
3、neral use of using ultrasonic coating thickness gages are described in ASTM D 6132 and the gage manufacturers instructions. This document focuses on the correct method for taking measurements.1.3 Current ultrasound technology may not be capable of accurately measuring the DFT of some coatings (see N
4、otes 8.1 and 8.2). 2. Description 2.1 The procedures described in this standard include criteria for determining the number of measurements, location of measurements, and whether the dry film thickness (DFT) of the coating conforms to project specifications. 2.2 Description of Gages: Ultrasonic gage
5、s use a transducer in the probe to send pulses into the coating and measure the time taken by that pulse to return to the probe tip to calculate coating thickness (see Note 8.3).2.3 DEFiniTiOnS2.3.1 Gage Reading: A single reading at one point.2.3.2 Spot Measurement: The average of at least three gag
6、e readings made within a 15 cm (6 inch) diameter circle.2.3.3 Structure: A unit composed of one or more connected concrete members. It is possible for a single concrete shape (beam, pipe, channel, etc.) to be considered a structure if it is painted in a shop.2.3.4 Homogeneous: of the same or similar
7、 in composition or structure. In this standard, the term “homogeneous coating” refers to a coating of uniform composition throughout that does not contain large, solid particles such as sand.2.3.5 Calibration: The controlled and documented process of measuring traceable calibration standards and ver
8、ifying that the results are within the stated accuracy of the gage. Cali-brations are typically performed by the gage manufacturer or by a qualified laboratory in a controlled environment using a documented process. The standards used in the calibration are such that the combined uncertainties of th
9、e resultant measure-ment are less than the stated accuracy of the gage.2.3.6 Verification: An accuracy check performed by the user using known reference standards.2.3.7 adjustment: The act of aligning the gages thick-ness readings to match those of a known sample in order to improve the accuracy of
10、the gage on a specific surface or in a specific portion of its measurement range.3. References3.1 The latest issue, revision, or amendment of the refer-enced standards in effect on the date of invitation to bid shall govern, unless otherwise specified. Standards marked with an asterisk (*) are refer
11、enced only in the Notes, which are not requirements of this standard.3.2 If there is a conflict between the requirements of any of the cited referenced standards and this standard, the requirements of this standard shall prevail.3.3 aSTM inTERnaTiOnaL STanDaRDS1* D 4138 Standard Test Methods for Mea
12、surement of Dry Film Thickness of Protective Coating Systems by Destructive, Cross-Sectioning MeansD 6132 Standard Test Method for Nondestructive Measurement of Dry Film Thickness of Applied Organic Coatings Using an Ultrasonic Gage1 ASTM International, 100 Barr Harbor Drive, West Conshohock-en, PA
13、19428-2959. Standards are available online from http:/www.astm.org.SSPC-PA 9February 1, 20082* D 7091 Standard Practice for Nondestructive Measurement of Dry Film Thickness of Nonmagnetic Coatings Applied to Ferrous Metals and Nonmagnetic, Nonconductive Coatings Applied to Non-Ferrous Metals* SSPC-P
14、a 2 Measurement of Dry Coating Thickness with Magnetic Gages4. Gage RequirementsThe ultrasonic gage shall be capable of measuring the thickness of a coating over a cementitious substrate. To qualify under this standard, the gage shall have a minimum accu-racy within 10%. All gages shall be calibrate
15、d and adjusted following the manufacturers instructions and be in accordance with ASTM D 6132. 5. Measurement Procedures 5.1 Verify that the gage will provide accurate readings over the coating to be measured, using the procedure in Note 8.2. 5.2 SPOT MEaSUREMEnT: Repeated gage readings, even at poi
16、nts close together, usually differ due to surface irregularities of the coating and the substrate (see Notes 8.4 and 8.5). Therefore, a minimum of three (3) gage readings shall be made for each spot measurement of the coating. For each new gage reading, move the probe to a new location within the 15
17、 cm (6 inch) diameter circle defining the spot. Each gage reading shall be at least 5 cm (2 inches) from the other gage readings. Discard any single unusually high or low gage reading that cannot be repeated consistently. Take the average of the acceptable gage readings as the spot measure-ment (see
18、 Note 8.6).5.3 nUMBER OF MEaSUREMEnTS: Make five (5) separate spot measurements (average of the gage readings, see Section 5.2) spaced arbitrarily over each 10 m2(108 ft2) area to be measured unless otherwise specified. The five spot measurements shall be made for each 10 m2(108 ft2) of area as foll
19、ows:5.3.1 For structures not exceeding 30 m2(323 ft2) in area, each 10 m2(108 ft2) (or increment thereof) area shall be measured.5.3.2 For structures not exceeding 100 m2(1,076 ft2) in area, three 10 m2(108 ft2) (or increment thereof) areas shall be arbitrarily selected by the inspector and measured
20、.5.3.3 For structures exceeding 100 m2(1,076 ft2) in area, the first 100 m2(1,076 ft2) shall be measured as stated in Section 5.3.2 and for each additional 100 m2(1,076 ft2) of area (or increment thereof), one 10 m2(108 ft2) area shall be arbitrarily selected by the inspector and measured.5.3.4 If t
21、he dry film thickness for any 10 m2(108 ft2) area or increment thereof (see Sections 5.3.1, 5.3.2 and 5.3.3) is not in compliance with the requirements of Section 6, additional measurements shall be made to isolate the non-conforming area, and each 10 m2(108 ft2) area painted during that work shift
22、shall be measured. 5.4 SPECiFYinG THiCKnESS: Both a maximum and a minimum thickness are customarily specified for the coating. If a maximum thickness value is not specified, (as in Restric-tion Level 4 of Table 1) the specified thickness shall be the minimum and there shall be no maximum. Table 1Res
23、triction Levels Coating Thickness on ConcreteThicknessSpotReadingarea ReadingLevel 1Minimum As specified As specifiedMaximum As specified As specifiedLevel 2Minimum As specified As specifiedMaximum 125% of maximum As specifiedLevel 3Minimum 75% of minimum As specifiedMaximum 125% of maximum As speci
24、fiedLevel 4Minimum 75% of minimum As specifiedMaximum Unrestricted UnrestrictedSSPC-PA 9February 1, 200836. COnFORManCE TO SPECiFiED THiCK-nESS6.1 Thickness Restriction Levels: Table 1 provides four thickness restriction levels. Level 1 is the most restrictive and does not allow for any deviation of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SSPCPAGUIDE92008MEASUREMENTOFDRYCOATINGTHICKNESSONCEMENTITIOUSSUBSTRATESUSINGULTRASONICGAGES 使用 超声波 测量计

链接地址:http://www.mydoc123.com/p-1054459.html