SANS 61326-2003 Electrical equipment for measurement control and laboratory use - EMC requirements《测量、控制及实验室用电气设备 电磁兼容(EMC)要求》.pdf
《SANS 61326-2003 Electrical equipment for measurement control and laboratory use - EMC requirements《测量、控制及实验室用电气设备 电磁兼容(EMC)要求》.pdf》由会员分享,可在线阅读,更多相关《SANS 61326-2003 Electrical equipment for measurement control and laboratory use - EMC requirements《测量、控制及实验室用电气设备 电磁兼容(EMC)要求》.pdf(43页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ICS 25.040.40 ISBN 0-626-14605-4 SANS 61326:2003 Edition 1 IEC 61326:2002 Edition 1 SOUTH AFRICAN NATIONAL STANDARD Electrical equipment for measurement,
4、 control and laboratory use EMC requirements This national standard is the identical implementation of IEC 61326:2002 and is adopted with the permission of the International Electrotechnical Commission. Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 t
5、el: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standards South Africa 2003 SANS 61326:2003 Edition 1 IEC 61326:2002 Edition 1 Table of changes Change No. Date Scope National foreword This South African standard was approved by STANSA TC 73, Electromagnetic compatibili
6、ty, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD61326Premire ditionFirst edition2002-02Matriels lectriques de mesure, de commandeet de laboratoire Prescriptions relatives la CEMElectrical
7、equipment for measurement,control and laboratory use EMC requirementsPour prix, voir catalogue en vigueurFor price, see current catalogue IEC 2002 Droits de reproduction rservs Copyright - all rights reservedAucune partie de cette publication ne peut tre reproduite niutilise sous quelque forme que c
8、e soit et par aucun procd,lectronique ou mcanique, y compris la photocopie et lesmicrofilms, sans laccord crit de lditeur.No part of this publication may be reproduced or utilized in anyform or by any means, electronic or mechanical, includingphotocopying and microfilm, without permission in writing
9、 fromthe publisher.International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.chCODE PRIXPRICE CODE WCommission Electrotechnique InternationaleInternational Electrotech
10、nical Commission 61326 IEC:2002 3 CONTENTSFOREWORD 7INTRODUCTION .111 Scope .132 Normative references152.1 General standards .152.2 Immunity standards152.3 Emission standards173 Definitions.174 General.215 EMC test plan .235.1 General .235.2 Configuration of EUT during testing235.2.1 General235.2.2
11、Composition of EUT .255.2.3 Assembly of EUT .255.2.4 I/O ports.255.2.5 Auxiliary equipment255.2.6 Cabling and earthing (grounding)255.3 Operation conditions of EUT during testing.255.3.1 Operation modes255.3.2 Environmental conditions .255.3.3 EUT software during test255.4 Specification of performan
12、ce criteria 255.5 Test description .276 Immunity requirements276.1 Conditions during the tests.276.2 Immunity test requirements 276.3 System and application aspects .296.4 Random aspects 296.5 Performance criteria 297 Emission requirements337.1 Conditions during measurements .337.2 Emission limits.3
13、38 Test results and test report .35Annex A (normative) Immunity test requirements for equipment intended for usein industrial locations.37Annex B (normative) Immunity test requirements for equipment used incontrolled EM environments.39Annex C (normative) Immunity test requirements for portable test
14、andmeasurement equipment .4161326 IEC:2002 5 Annex D (normative) Test configurations, operational conditions and performance criteriafor sensitive test and measurement equipment for EMC unprotected applications.43Annex E (normative) Test configurations, operational conditions and performancecriteria
15、 for portable test, measuring and monitoring equipment used in low-voltagedistribution systems.49Annex F (normative) Test configurations, operational conditions and performancecriteria for transducers with integrated or remote signal conditioning 57Figure 1 Examples of ports .19Figure E.1 Test set-u
16、p for portable test, measuring and monitoring equipment basedon IEC 61000-4-3 53Figure E.2 Example of connection details for voltage measurements.55Figure E.3 Example of connection details for current measurements .55Figure F.1 Example of a transducer with integrated signal conditioning .59Figure F.
17、2 Example of a transducer with remote signal conditioning 59Figure F.3 Example of the configuration of a force transducer with remote measured-value processing .67Figure F.4 Additional maximum measuring error (fz) versus the maximum measuringerror (fy) for continuous disturbances.71Figure F.5 Additi
18、onal maximum measuring error (fz) versus the maximum measuringerror (fy) for transient disturbances 73Figure F.6 Example of the configuration of a pressure transducer .75Figure F.7 Additional maximum measuring error (fz) versus the maximum measuringerror (fy) 79Table 1 Minimum immunity test requirem
19、ents29Table 2 Example of evaluation of immunity test results .33Table 3 Emission limits for class A equipment.35Table 4 Emission limits for class B equipment.35Table A.1 Immunity test requirements for equipment intended for use in industriallocations .37Table B.1 Immunity test requirements for equip
20、ment used in controlled EMenvironments.39Table C.1 Immunity test requirements for portable test and measurement equipment 41Table F.1 Performance criteria for the different functions 63Table F.2 Circuitry actions for generating an output signal for simulation of amechanical load on the transducer 69
21、Table F.3 Performance criteria for the different functions 69Table F.4 Additional maximum measuring error (fz)for a given maximum measuringerror (fy) for continuous disturbances.71Table F.5 Additional maximum measuring error (fz) for a given maximum measuringerror (fy) for transient disturbances 71T
22、able F.6 Performance criteria for the different functions 77Table F.7 Additional maximum measuring error (fz) for a given maximum measuringerror (fy) 7761326 IEC:2002 7 INTERNATIONAL ELECTROTECHNICAL COMMISSION_ELECTRICAL EQUIPMENT FOR MEASUREMENT,CONTROL AND LABORATORY USE EMC REQUIREMENTSFOREWORD1
23、) The IEC (International Electrotechnical Commission) is a worldwide organization for standardization comprisingall national electrotechnical committees (IEC National Committees). The object of the IEC is to promoteinternational co-operation on all questions concerning standardization in the electri
24、cal and electronic fields. Tothis end and in addition to other activities, the IEC publishes International Standards. Their preparation isentrusted to technical committees; any IEC National Committee interested in the subject dealt with mayparticipate in this preparatory work. International, governm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS613262003ELECTRICALEQUIPMENTFORMEASUREMENTCONTROLANDLABORATORYUSEEMCREQUIREMENTS 测量 控制 实验室 用电 设备

链接地址:http://www.mydoc123.com/p-1031590.html