SANS 10120-2 MG-1996 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 2 Project specification Section MG Bit.pdf
《SANS 10120-2 MG-1996 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 2 Project specification Section MG Bit.pdf》由会员分享,可在线阅读,更多相关《SANS 10120-2 MG-1996 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 2 Project specification Section MG Bit.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. SABS 0120-2 Section MG:l996 Bituminous surface treatment First revision Part 2 : Project specification, Portion 2 Section MG Contents 1 Essentiai project
4、 specification clauses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . l 2 Essentialdata 1 3 Additionalclauses . l 3.1 General . 1 3.2 Normalprojects . 1 3.2.1 Sandsal 2 3.2.2 Final rolling of aggregate (double surface
5、 treatment) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3.2.3 Mass batching of slurry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . 2 3.2.4 Initialtes
6、ting 2 3.3 Prestigeprojects . 2 3.4 Subeconomic projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , . . . 2 3.5 Labour-basedproj . 3 First Revision 24 June 1996. This section of the code supersedes SABS 0120
7、-2 : Section MG:1981 Approved by the PRESIDENT OF THE SOUTH AFRICAN BUREAU OF STANDARDS CODE OF PRACTICE SABS 0120-2 : Section MG:1996 SABS 1200 MG : Bituminous surface treatment NOTES 1 Number the PSMG clauses in portion 2 of the project specification in the sequence in which the clauses to which t
8、hey relate appear in SABS 1200 MG. 2 The clause number(s) given in brackets at the beginning or after the heading of a clause istare, unless otherwise stated, the number(s) of the relevant clause(s) of SABS 1200 MG. 1 Essential project specification clauses Set out suitable clauses in portion 2 of t
9、he project specification to provide essential information as follows: a) (5.5.1) Specify whether one or two coats of bituminous binder are required. b) (5.5.1) Specify whether one or two coats of slurry seal are required. 2 Essential data The availability of certain essential data could affect the p
10、rices tendered. Except where such data have been given in the schedule or on the tender drawings, set out suitable clauses covering items such as the following in portion 2 of the project specification: a) (Clause 1) State the surface treatment required. b) (3.1) When relevant, state which prime is
11、to be used. c) (3.3 and 3.5) State which types and grades of bituminous binders are to be used. d) (3.6) State whether grade 1, grade 2 or grade 3 aggregate is required. e) (3.7) State the grade or type (or both) of slurry required. f) (3.9) When relevant, state which filler is to be used. g) (5.2)
12、State whether a prime coat is required and, if so, the type and, when relevant, the grade and over which parts of the works it is required. h) (5.4.1) When relevant, state the nominal sizes of aggregate to be used for double surface treatment. i) (5.4.6) State whether a fog spray is required. If so,
13、 provide a schedule item. j) (5.4.7) When relevant, state whether pre-coating of the second application of aggregate is required for double surface treatment. If so, provide schedule items and, where necessary, amend the pre-coating application rate. k) (5.5.1) When relevant, state the nominal size
14、of aggregate and the number of applications of bituminous binder and of slurry seal required. 1) (5.6.1) When relevant, state the nominal size of aggregate to be used for single surface treatment. m) Unless details have been set out in the drawings, provide a list of street names or road sections to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS101202MG1996CODEOFPRACTICEFORUSEWITHSTANDARDIZEDSPECIFICATIONSFORCIVILENGINEERINGCONSTRUCTIONANDCONTRACTDOCUMENTSPART2PROJECTSPECIFICATIONSECTIONMGBITPDF

链接地址:http://www.mydoc123.com/p-1028503.html