1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.Copyright 2005 SAE InternationalAll rights reserved. No part of this publication may be
3、reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: 724-776-4970 (outside USA)Fax: 724
4、-776-0790Email: custsvcsae.orgSAE WEB ADDRESS: http:/www.sae.orgAEROSPACE RECOMMENDED PRACTICEARP726REV.AIssued 1963-12Revised 1997-12Reaffirmed 2005-10Superseding ARP726Universal Leak DetectorFOREWORDChanges in this revision are format/editorial only.1. SCOPE:This recommended practice covers a self
5、-contained detection system which is capable of pressurizing a closed system up to 70 psig with halogen (tracer) gas and up to 3500 psig with nitrogen.1.1 An external tracer gas supply may be used to increase the capacity of the system. The detector shall be capable of detecting leaks as small as .0
6、5 ounce of tracer gas per year, with a system pressure of 70 psig or less.1.2 Purpose:The purpose of this document is to provide a recommended practice for the design of a universal leak detector which will pressurize a closed system with a mixture of inert and tracer gas and provide a probe and det
7、ector to indicate location and rate of system leakage with a high degree of accuracy.2. REFERENCES:The following military specifications may be applicable and provide useful information:MIL-N-6011 Nitrogen Liquid and GasMIL-S-8512 Support Equipment, Aeronautical, Special General Specification for th
8、e Design ofMIL-D-70327 Drawing, Engineering and Associated ListsMIL-M-8090 Mobility Requirements, Ground Support Equipment, General Specification forMS 33586 Metals - Definition of DissimilarMIL-H-5593 Hose, Aircraft Low Pressure, FlexibleMIL-H-8788 Hose, Hydraulic and Pneumatic High PressureHandboo
9、k H28 Screw Threads Standards for Federal ServicesSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/ARP726A SAE ARP726 Revision A- 2 -3. GENERAL REQUIREMENTS:3.1 Material and Workmanship:3.1.1 Material: Material specified for use
10、in fabrication shall be of the best commercial quality and suitable for the purpose.3.1.2 Workmanship: All details of workmanship specified on the drawings shall be in accordance with high-grade commercial practices. The article produced shall be free of defects which might affect its serviceability
11、 or function.4. SPECIFIC REQUIREMENTS:4.1 General:The console shall be capable of controlling the pressurization of a closed system with tracer gas and nitrogen gas, within maximum pressures herein specified. The assembly shall be capable of monitoring the system pressures.4.2 Mobility:The console a
12、ssembly shall have the capability of being easily moved on casters. The console assembly shall be able to pass thru a 30 inch wide opening.4.3 Design Configuration:Design configuration shall be of a mobile console concept (see Figures 1 and 2). The assembly shall contain, but not be limited to the f
13、ollowing:4.3.1 Console: The console shall contain hardware necessary to control pressurization of the system being leak-tested, detect the presence of leaks, and vent the system being checked. The console shall have adequate storage space to house all components such as hoses, cables, and instrument
14、s.4.3.2 Standard Control Unit: The console shall contain a standard control unit, including a voltage regulator, a vibrator type air pump, an audible alarm, and a control panel.4.3.3 Detector: The tracer gas detector shall be a hand-held detector used as a probe for passing over welds, seams, joints
15、 and other areas of potential leakage.4.3.4 Nitrogen Gas Regulator: The nitrogen gas regulator shall be capable of regulating nitrogen gas pressure of 3600 psig to an outlet pressure of 100 5 psig, 500 20 psig, 1500 50 psig and3500 75 psig.SAE ARP726 Revision A- 3 -4.3.5 Tracer Gas Regulator: The tr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP726A1997UNIVERSALLEAKDETECTOR 通用 检漏 PDF

链接地址:http://www.mydoc123.com/p-1023299.html