1、SAE ARPxSO9C 80 W 8357390 0028996 3 = !Ir WAC AEROSPACE RECOMMENDED p RACTI CE Society 400 COMMONWEALTH of Automotive DRIVE. WARRENDALE. Engineers, PA Inc. 15096 AN -N NATIONAL STANDARD I ARP 504C Issued 11- 15- 76 Revised 4- 15- 80 - I IGNITION SYSTEM TESTING - METERING AND POWER SUPPLIES 1. PURPOS
2、E This Aerospace Recommended Practice (ARP) provides a design standard for power supplies applicable to ignition system development testing. 2. SCOPE This procedure establishes the ignition system power supply design parameters for aero- nautical engine ignition system testing. 3. FOR D.C. SYSTEM ME
3、ASUREMENTS 3.1 3.2 3.3 3.4 3.5 3.6 0 Use meters with accuracy of 2% of full scale or kl volt , whichever is less. Use lowest range meters for minimum error readings of mid-scale, or greater. Use power supplies having not more than 1 volt drop at the terminals when a 10 ampere load is applied. Use a
4、capacitance across the power supply terminals large enough (2000 mfd plus) to ensure meeting ripple requirements of 3.3 and to provide a low impedance return path for the A.C. component that may be developed by the ignition exciters. The power supply shall be capable of being varied over the nominal
5、 supply voltage range that wiU be available to the system so as to allow checking of operation at the design limits of the system. Use power supplies having A.C. RMS ripple content no greater than 3% of average D .C. level, measured with 10 ampere load. Power supply circuit accessories such as filte
6、rs, relays and long power leads should be considered part of the power supply and meet the above requirements. Locate meters for measuring input characteristics at the input terminal of the system. Use moving coil type D .C. ammeters with i 2% accuracy for measuring average value of input current. D
7、ue to the varying characteristics of the input current over the charging cycle in capacitor discharge type system, the input current should be specific and read as the average of the minimum and maximum meter indications. If an automatic electronic averaging meter is available, it may be used. Digit
8、al meters are not recommended due to the varying CharactePistics. If it is required to measure current peaks, a suitable peak reading instru- ment may be connected external to the supply. 4. FOR A.C. SYSTEM MEASUREMENTS 4.1 Use frequency meters with accuracy of Il% of full sclae. Use lowest range me
9、ters for min- imum error readings at mid-scale , or greater. CopyriQht 1980 by Societ of Automotive Engineen, Inc. All rights reserveJ. Printed in U. S.A. 4RP 504C -2- 1 4.2 Use electronic true RMS , dynanmmeter or iron vane type meters with 5 28 of full scale accuracy for meneuring input current or
10、 voltage RMS value. Meters should be calibrated, or accuracy rnte, up to the highest frequency to be measured. Due to the varying characteristics of the in- put current over the ehinrging cycle in capacitor discharge type systems, the input current shoulc be specified and read na the average of the
11、minimum and maximum meter indications. Digital nmmetore aro not recommended due to this varying characteristic. If it is required to measure current peaks, n suitable peak reading instrument may be connected external to the power supply 4.3 Use power eupplieei having regulation capable of providing,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP504C1980IGNITIONSYSTEMTESTINGMETERINGANDPOWERSUPPLIES 点火 系统 测试 计量器 能源 供给 PDF

链接地址:http://www.mydoc123.com/p-1023027.html