NAVY MIL-PRF-17773 C-2006 SWITCHES BUS TRANSFER ELECTRIC POWER AUTOMATIC AND MANUAL《自动或手动电力转接母线开关》.pdf
《NAVY MIL-PRF-17773 C-2006 SWITCHES BUS TRANSFER ELECTRIC POWER AUTOMATIC AND MANUAL《自动或手动电力转接母线开关》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-17773 C-2006 SWITCHES BUS TRANSFER ELECTRIC POWER AUTOMATIC AND MANUAL《自动或手动电力转接母线开关》.pdf(29页珍藏版)》请在麦多课文档分享上搜索。
1、Comments, suggestions, or questions on this document should be addressed to: Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard, DC 20376-5160 or emailed to CommandStandardsnavy.mil, with the subject line “Document Comment”. Since contact
2、 information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 6110 INCH-POUND MIL-PRF-17773C(SH) 21 November 2006 SUPERSEDING DOD-S-17773B(SH) 14 September 1983 PERFORMANCE SPECIFICATION SWITCHES,
3、BUS TRANSFER, ELECTRIC POWER, AUTOMATIC AND MANUAL This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the Automatic Bus T
4、ransfer Switch (ABT) (see 6.4.1) and the Manual Bus Transfer Switch (MBT) (see 6.4.13), herein referred to as ABT, MBT, or switch(es), for use on surface and submarine Naval vessels. Unless otherwise specified herein, this specification applies to both ABTs and MBTs. Requirements for Static or Solid
5、 State ABTs (SABTs) are not defined in this specification. MIL-PRF-32150 specifies requirements for SABTs. 1.2 Classification. Switches have the following characteristics: (Part or identifying number (PIN) codes are provided along with the classifications to avoid unnecessary duplication of informat
6、ion in 1.3.) 1.2.1 Voltage. Switch voltages are as follows: Voltage PIN Code 120 V 1 208 V (400 Hz only) 2 240 V (DC only) 3 450 V (AC only) 4 Other 6 1.2.2 Frequency. Switch frequencies are as follows: Frequency PIN Code 60 Hz A DC D 400 Hz F Provided by IHSNot for ResaleNo reproduction or networki
7、ng permitted without license from IHS-,-,-MIL-PRF-17773C(SH) 1.2.3 Configuration type. Switch configuration types are as follows: Configuration Type (CT) Description PIN Code ABT has: (a) control circuit time delay (0.3 to 0.5 seconds) (see 6.4.5) and (b) single phase protection (see 3.4.2.3.12) (se
8、e 6.4.8) on normal bus and (c) is instantaneous (see 6.4.10) and (d) normal seeking. 01 ABT has: (a) control circuit time delay (0.3 to 0.5 seconds) and (b) full phase protection on normal bus and (c) is instantaneous and (d) normal seeking. 02 ABT has: (a) control circuit time delay (0.3 to 0.5 sec
9、onds) and (b) line circuit time delay (see 6.4.12) or in-phase monitoring (see 6.4.9) and (c) single phase protection on normal bus and (d) is normal seeking. 03 ABT has: (a) single phase protection on normal bus and (b) is instantaneous and (c) power seeking. 04 ABT has: (a) control circuit time de
10、lay (0.3 to 0.5 seconds) on voltage sensing and (b) single phase protection on normal bus and (c) instantaneous transfer (see 6.4.22) on frequency sensing and (d) random transfer below 25 percent voltage and (e) contains in-phase monitoring. 05 ABT is for DC (direct current) only and has: (a) no lin
11、e circuit time delay and (b) single phase protection on normal bus and (c) is power seeking. 06 ABT has: (a) single phase protection on normal bus and (b) senses voltage and frequency and (c) has transfer stabilization time and (d) has an operating transfer time (see 6.4.15) of 70 milliseconds maxim
12、um upon voltage failure and (e) is instantaneous and (f) power seeking. 07 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-17773C(SH) Configuration Type (CT) Description PIN Code ABT is similar to configuration type 07 with additional curre
13、nt sensing on load terminals to inhibit transfer during overload conditions. 08 ABT is the same as configuration type 03 but is: (a) three-way and (b) normal seeking between normal and alternate and (c) power seeking to emergency and (d) automatically signals the start of the emergency power source
14、and (e) open mounting type and (f) facilities for dead front mounting and (g) automatic starting of emergency/auxiliary generator and (h) DC has no line circuit time delay. 09 ABT has: (a) control circuit time delay 2.5 to 3.5 seconds and (b) single phase protection on normal bus and (c) in-phase mo
15、nitoring and (d) is normal seeking. 10 ABT is the same as configuration type 03, but is power seeking. 11 Manual Bus Transfer Switch 12 Note: 1. In-phase monitoring is not used in 400-Hz ABTs on Naval vessels. 1.2.4 Special features. Switch special features are as follows: Special Feature PIN Code S
16、pecial Feature(s) S No Special Feature(s) X 1.2.5 Current rating. Switch current ratings are as follows: Current Rating PIN Code 025 to 600 amps XXX 1.2.6 Cabinet integrity. Switch cabinet integrities are as follows: Cabinet Integrity PIN Code Drip-proof D Splash-proof S Watertight W Open Mounted O
17、3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-17773C(SH) 1.3 Part or identifying number (PIN). PINs to be used for switches acquired to this specification are created as follows: (see 1.2.1 through 1.2.6 for PIN Code designations) M Prefi
18、x Specification Number Hyphen Voltage Frequency CT Special Feature Current Rating (maximum) Cabinet Integrity M 17773 - 4 A 01 S 600 D The example above (M17773-4A01S600D) is for a 450-V, 60-Hz, instantaneous and normal seeking, special feature, 600-amp maximum current rating, drip-proof ABT. 2. APP
19、LICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been
20、made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The fol
21、lowing specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. FEDERAL STANDARDS FED-STD-595-26307 - Colors Used in Government Procurement DEPARTME
22、NT OF DEFENSE SPECIFICATIONS MIL-S-901 - Shock Tests, H.I. (High-Impact) Shipboard Machinery, Equipment, and Systems, Requirements for MIL-E-917 - Electric Power Equipment Basic Requirements MIL-E-2036 - Enclosures for Electric and Electronic Equipment MIL-DTL-2212 - Contactors and Controllers, Elec
23、tric Motor AC or DC, and Associated Switching Devices MIL-DTL-3661 - Lampholders, Indicator Lights, Indicator Light Housings, and Indicator Light Lenses, General Specification for MIL-L-3661/38 - Housings, Indicator Light, Style LH80 MIL-L-3661/54 - Lenses, Indicator Light, Style LC40 MIL-L-3661/62
24、- Lampholder, Lights, Indicator (Housing), Style LH95, (for D.C. Applications) MIL-L-3661/63 - Lampholder, Lights, Indicator (Housing), Style LH96 MIL-L-3661/64 - Lampholder, Lights, Indicator (Housing), Style LH97 MIL-L-3661/65 - Lampholder, Lights, Indicator (Housing), Style LH98 MIL-DTL-15024 - P
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF17773C2006SWITCHESBUSTRANSFERELECTRICPOWERAUTOMATICANDMANUAL 自动 手动 电力 转接 母线 开关 PDF

链接地址:http://www.mydoc123.com/p-980895.html