1、Beneficial comments (recommendations, additions, deletions) and any pertinentdata which may be of use in improving this document should be addressed to:Commander, SEA 05Q, Naval Sea Systems Command, 2531 Jefferson Davis Hwy,Arlington, VA 22242-5160 by using the Standardization Document ImprovementPr
2、oposal (DD Form 1426) appearing at the end of this document or by letter.AMSC N/A FSC 4140DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.INCH-POUNDMIL-PRF-19004B25 May 2001SUPERSEDINGMIL-F-19004A18 April 1983PERFORMANCE SPECIFICATIONFANS, CENTRIFUGAL, VENTILATION, N
3、AVAL SHIPBOARDThis specification is approved for use by the Naval Sea Systems Command,Department of the Navy, and is available for use by all Departments andAgencies of the Department of Defense.1.SCOPE1.1 Scope. This specification covers centrifugal fans for use in Navalshipboard heating, ventilati
4、ng, and air conditioning systems.1.2 Classification. Fans covered by this specification are of the followingtypes, as specified (see 6.1).Type CC - Centrifugal, motor driven (high-impact - shock)Type X-CC - Centrifugal, motor driven (non-Shock, commercial motor)2.APPLICABLE DOCUMENTS2.1 General. The
5、 documents listed in this section are specified in Sections3 and 4 of this specification. This section does not include documents citedin other sections of this specification or recommended for additionalinformation or as examples. While every effort has been made to ensure thecompleteness of this l
6、ist, document users are cautioned that they must meetall specified requirements documents cited in sections 3 and 4 of thisspecification, whether or not they are listed.2.2 Government documents.2.2.1 Specifications, standards. The following specifications, standards,publications and handbooks form a
7、 part of this document to the extentspecified herein. Unless otherwise specified, the issues of these documentsare be those listed in the issue of the Department of Defense Index ofSpecifications and Standards (DODISS) and supplement thereto, cited in thesolicitation (see 6.2).SPECIFICATIONSDEPARTME
8、NT OF DEFENSEMIL-S-901 Shock Tests, H.I. (High-Impact); ShipboardMachinery, Equipment and Systems, RequirementsforMIL-B-17931 Bearings, Ball, Annular, for Quiet OperationProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-19004B2STANDARDSDEPARTME
9、NT OF DEFENSEMIL-STD-167-1 Mechanical Vibrations of Shipboard Equipment(Type I - Environmental and Type II - Internallyexcited)MIL-STD-1399 Interface Standard for Shipboard Systems, Sect300, Electric Power, Alternating CurrentMIL-STD-2031 Fire otherwise, it shall be shock tested on thelight weight m
10、achine as specified for grade A shock of MIL-S-901. Shock testacceptance shall not be contingent upon the ability of the equipment tosatisfy noise and vibration requirements. Evidence of fragmentation orProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,
11、-MIL-PRF-19004B12missile effect of parts, deformation that will cause active interferencebetween parts, or failure to operate shall be cause for rejection. Resilientmounting shall not be used unless specified (see 6.2). Fan-motor units thathave passed this test may be used as production units after
12、replacement ofmotor bearings.4.7.1.1 Shock on lightweight machine. The motor and fan support shall bemounted as shown on Figure 4c of MIL-S-901. The test shall consist of nineblows with the unit operating at maximum speed and nine blows with the unitnot engaged.4.7.1.2 Shock on medium weight machine
13、. The test of a fan-motor unit shallconsist of nine blows indicated in Table VI. The required mountings forrequired tests in Table VI are as follows: (Designations for rotation anddischarge of centrifugal fans are in accordance with AMCA 2406-66).1. CWTH or CCTH, motor and impeller shaft horizontal.
14、2A. CWTH or CCTH, motor and impeller shaft horizontal, mounting baseinclined 30.2B. CWUB or CCOB, base, motor and impeller shaft inclined 30, motor ontop.TABLE VI. Test on medium weight shock machine.BlowNo.GroupNo.HAMMERdropAnviltravel (in)OperatingConditionFanOrientation123456789IIIIIIIIIIIIIIIIII
15、(Based onweight, seeMIL-S-901)331.5331.5331.5SecuredOperatingSecuredOperatingSecuredOperatingSecuredOperatingSecuredNo. 1No. 1No. 1No. 2ANo. 2ANo. 2ANo. 2BNo. 2BNo. 2BUpon completion of the shock test, post-shock test inspection, and testsspecified in Table V, the fan-motor unit shall be returned to
16、 the contractorfor examination and further testing.4.7.2 Vibration test. Fan-motor units shall be subjected to type Ienvironmental vibration tests as specified in MIL-STD-167-1. The exploratoryvibration test specified in MIL-STD-167-1 shall include frequencies up to 33Hz at the table amplitude speci
17、fied herein. The vibration test shall beconducted as specified in 4.11. Any unit that fails to meet any requirementshall be rejected.4.7.3 Balance test. In this test, the fan-motor unit shall be operated atmaximum speed and free delivery, with shaft horizontal. It shall be suspendedfrom a stand by m
18、eans of two elastic vibration cords, one secured to each endflange. The cords shall have a natural frequency of less than 1/4 of theminimum rotational frequency of the unit in Hz. The static deflection shall bewithin the limits of MIL-STD-167-1 for elastic mounting elements, and thisshall be the bas
19、is for determining cord size for each unit tested. As analternative to the suspension test, the fan-motor unit shall be suspended froman electric hoist by means of two chains, one secured to the end flanges ofthe fan-motor unit (that is, the ends of the chain secured to oppositeflanges); one secured
20、 to the electric hoist and to the center of the chainsecured to the end flanges. The length of the chains shall be not less than 15inches nor greater than 35 inches, and the link size of the chains shall benot less than 1/4 inch nor greater than 3/8 inch. With either method, theinternally excited vi
21、brational displacement (single amplitude mils, peak)shall be measured as follows: four axial measurements 90 degree apart on theface of each end flange, one horizontal measurement perpendicular to the axisProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,
22、-,-MIL-PRF-19004B13on the edge of each flange, and one vertical measurement on the top edge ofeach flange. The maximum amplitude of vibration shall be the maximum singlereading and not an average. The operating frequency at which the maximumamplitude occurs shall be measured. Exceeding vibration lim
23、its specified in3.9.2 is cause for rejection.4.7.4 Performance. Performance tests shall be conducted in accordance withAMCA 210. Any of the alternate test stands and associated instrumentation maybe used. The total pressure or the volume or both not being within thespecified limits is cause for reje
24、ction.4.7.4.1 Stall and recovery. Tests shall be conducted in accordance with AMCA210.4.7.5 Airborne noise. Octave band sound power levels for a fan-motor unitshall consist of the measurement of sound pressure levels and the computationof sound power levels in accordance with procedures and instrume
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF19004B2001FANSCENTRIFUGALVENTILATIONNAVALSHIPBOARD 海军 透气 离心 通风机 PDF

链接地址:http://www.mydoc123.com/p-980908.html