1、Lessons Learned Entry: 1803Lesson Info:a71 Lesson Number: 1803a71 Lesson Date: 2007-7-31a71 Submitting Organization: JPLa71 Submitted by: David Oberhettingera71 POC Name: Eric Archer (Supervisor, Spacecraft Transponders)a71 POC Email: Eric.D.Archerjpl.nasa.gova71 POC Phone: 818-354-7350Subject: CSAM
2、 Augments X-Ray Inspection of Die Attach (MRO Ka-Band Anomaly) Abstract: An in-flight failure of a hybrid amplifier used to derive the Ka-band downlink signal for Mars Reconnaissance Orbiter suggests that X-ray screening alone may not be adequate to determine the quality of coverage of the eutectic
3、die attach. CSAM is a non-destructive internal inspection technique that can complement high resolution X-rays by isolating variations in material properties. When screening RF hybrids and other critical components, consider the use of CSAM to augment high resolution X-ray inspection.Description of
4、Driving Event: After 6000 hours of nearly continuous in-flight operation aboard Mars Reconnaissance Orbiter (MRO), the Ka-band circuitry in the primary Small Deep Space Transponder (SDST-1) experienced an abrupt increase in power consumption. It abruptly decreased three hours later, permanently disa
5、bling the Ka-band downlink (References (1) and (2). This was likely due to an internal short circuit within the metal-semiconductor field-effect transistor (MESFET) hybrid amplifier used to derive the Ka-band signal within the SDST, which in turn raised the junction temperature and caused an open ci
6、rcuit in the hybrid. The X-band hybrid amplifier in SDST-1, as well as the X-band hybrid amplifier in the backup SDST-2, may also have been overstressed. A possible cause of the short circuit is a poor or failed eutectic bond between the hybrid device and the copper-molybdenum carrier. The process o
7、f mounting a semiconductor die/chip to a substrate or package is known as die attach. Methods include eutectic bonding (soldering) on ceramic or metal Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-substrates, adhesive bonding, and glass bonding. Ho
8、wever, soldering is preferred for high power devices because of its good thermal/electrical conductivity and ability to accommodate thermal expansion. A eutectic bond is formed by heating two or more materials in a joint such that they diffuse together to form a (eutectic) alloy. Manufacturing techn
9、ology has not eliminated voids and disbonds in the bonding layers that can increase the likelihood of die cracking, increase the chip operating temperature, and weaken the die bonds. This hybrid device failure mode is a risk for other SDST builds, and some flight hardware for the Kepler and Juno mis
10、sions may be replaced. The primary method for non-destructive evaluation (NDE) of die attach fabrication is high resolution X-rays. Following the MRO failure, the eutectic (AuSn solder) bond X-rays used to screen the parts were reexamined and revealed no voids between the die and the package (Refere
11、nce (3). Subsequently, JPL employed an ultrasound inspection technique known as C-mode Scanning Acoustic Microscopy (CSAM). Unlike X-rays, which depict the integrated density of material between the X-ray source and detector, CSAM technology can examine a specific layer. This distinction is particul
12、arly important when looking for disbonding defects such as non-wetting of surfaces or delamination. Figure 1 is an X-ray of a spare MRO hybrid die; it shows 3 void areas on the left side of the chip, as well as an unfilled via, but does not show areas of poor die attach. In the corresponding CSAM im
13、age (Figure 2), the 3 large void areas are clearly visible, as well as some smaller ones. The CSAM ultrasound image provides enough detail that, after conversion to a digital image (Figure 3), a more quantitative assessment can be performed that states the total area of disbonds and voids as a perce
14、ntage of the total die area. Figure 1 is a grayscale image of a rectangular die attach. Thirteen filled vias scattered across the die appear as small black circles, and a single unfilled via appears as a white circle. Between the faintly visible traces are three shadowy ovals that are apparently voi
15、ds.Figure 1. Microfocus X-ray of hybrid amplifier die (S/N D209) with lid Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Figure 2 is a grayscale image that is clearly the same rectangular die attach. This CSAM image is somewhat grainier, but it show
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS18032007LESSONSLEARNEDCSAMAUGMENTSXRAYINSPECTIONOFDIEATTACHMROKABANDANOMALYPDF

链接地址:http://www.mydoc123.com/p-1019297.html