1、*USACE / NAVFAC / AFCESA / NASA UFGS-08 51 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 51 13 (August 2009)UFGS-08 51 13 (January 2008) UFGS-08 51 13.00 20 (July 2006)UFGS-08 51 13.00 40 (October 2006)UFGS-08 51 14.00 10 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences ar
2、e in agreement with UMRL dated April 2011*SECTION TABLE OF CONTENTSDIVISION 08 - OPENINGSSECTION 08 51 13ALUMINUM WINDOWS05/11PART 1 GENERAL1.1 REFERENCES1.2 CERTIFICATION1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Shop Drawing Requirements1.4.2 Sample Requirements1.4.2.1 Finish Sample Requirements1.4.
3、2.2 Window Sample Requirements1.4.3 Design Data Requirements1.4.4 Test Report Requirements1.5 DELIVERY AND STORAGE1.6 PROTECTION1.7 SUSTAINABLE DESIGN REQUIREMENTS1.7.1 Local/Regional Materials1.7.2 Environmental Data1.7.3 Plastic Identification1.8 FIELD MEASUREMENTS1.9 PERFORMANCE REQUIREMENTS1.9.1
4、 Wind Loading Design Pressure1.9.2 Tests1.10 DRAWINGS1.11 WINDOW PERFORMANCE1.11.1 Structural Performance1.11.2 Minimum Antiterrorism Performance1.11.2.1 Computational Design Analysis Method1.11.2.2 Alternate Dynamic Design Analysis Method1.11.2.3 Standard Airblast Test Method1.11.3 Air Infiltration
5、1.11.4 Water Penetration1.11.5 Thermal PerformanceSECTION 08 51 13 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1.11.6 Life Safety Criteria1.11.7 Sound Attenuation1.12 QUALIFICATION1.13 MOCK-UPS1.14 WARRANTYPART 2 PRODUCTS2.1 WINDOWS2.1.1 Aw
6、ning Windows (AP)2.1.2 Casement Windows (C)2.1.3 Hung Windows (H)2.1.3.1 Window Materials2.1.4 Horizontal Sliding Windows (HS)2.1.5 Projected Windows (AP)2.1.6 Top-Hinged Windows (TH)2.1.7 Vertically Pivoted Windows (VP)2.1.8 Fixed Windows (F)2.1.9 Forced Entry Resistant Windows2.1.10 Glass and Glaz
7、ing2.1.11 Calking and Sealing2.1.12 Weatherstripping2.1.13 Sash Poles2.2 FABRICATION2.2.1 Provisions for Glazing2.2.2 Weatherstripping2.2.3 Fasteners2.2.4 Adhesives2.2.5 Drips and Weep Holes2.2.6 Combination Windows2.2.7 Mullions and Transom Bars2.2.8 Accessories2.2.8.1 Hardware2.2.8.2 Fasteners2.2.
8、8.3 Window-Cleaner Anchors2.2.8.4 Window Anchors2.2.9 Finishes2.2.9.1 Anodic Coating2.2.9.2 Organic Coating2.2.10 Screens2.3 SPECIAL OPERATORS2.3.1 Pole Operators2.3.2 Extension Crank Operators2.3.3 Mechanical Operators2.4 THERMAL-BARRIER WINDOWS2.5 MULLIONS2.6 WINDOW CLEANERS BOLTSPART 3 EXECUTION3
9、.1 SCHEDULE3.2 INSTALLATION3.2.1 Method of Installation3.2.2 Dissimilar Materials3.2.3 Anchors and Fastenings3.2.4 Adjustments After Installation3.3 CLEANING3.4 WASTE MANAGEMENTSECTION 08 51 13 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- E
10、nd of Section Table of Contents -SECTION 08 51 13 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-08 51 13 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-08 51 13 (August 2009)UFGS-08 51 13 (January 2
11、008) UFGS-08 51 13.00 20 (July 2006)UFGS-08 51 13.00 40 (October 2006)UFGS-08 51 14.00 10 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 08 51 13ALUMINUM WINDOWS05/11*NOTE: This guide specification covers the requirements for R, LC,
12、CW and AW performance class aluminum windows.Note: Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, d
13、eleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welc
14、ome and should be submitted as a Criteria Change Request (CCR).*1. Windows requiring UL fire rating must be steel, and may occur in conjunction with aluminum windows which cannot be approved for this use. When steel windows are used in conjunction with aluminum, specify finish matching aluminum wind
15、ows. Steel windows should be specified in Section 08 51 23 STEEL WINDOWS.2. Aluminum windows are not acceptable for use as security windows which should be steel, specified in Section 08 51 23 STEEL WINDOWS. Security steel windows are designed and constructed to give protection against unauthorized
16、entrance and removal SECTION 08 51 13 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-of materials from warehouses and other storage type areas; they are not designed for detention use. Guard windows for detention use are not included in this g
17、uide; where such windows are desired, consult Steel Window Institute Recommended Specifications and manufacturers data, and specify in Section 08 51 23 STEEL WINDOWS.3. Specify the following items of related work under other sections of the specifications:a. Glass and glazing and the furnishing of g
18、lazing clips and gaskets.b. Calking and sealants.c. Structural building supports at window mullions.d. Wood subframes for windows in frame walls.e. Drilling and tapping for attachment of window shades, drapery rods, and venetian blinds. The drilling and tapping of window frames to receive brackets f
19、or shades, venetian blinds, and curtain rods has been omitted from this specification. It is contemplated that this work will be done after erection of windows by the trade for the item to be installed. On projects where factory drilling for these items is required, revise this specification accordi
20、ngly.f. Brackets and supports for window shades, drapery rods, and venetian blinds.g. Electrical requirements for motor driven operators.*NOTE: On the drawings, show:1. Sizes and types of windows; metal and wood subframes, casings, or stools; and hardware.2. Sizes, location, and swing of ventilators
21、; direction of slide for sliding ventilators; location and details of fixed sash.3. Typical window sections and details. Show glass thickness. Show special glazing.4. Method of anchoring windows to adjoining construction; size and types of clips, anchors, screws, or other fasteners.5. Details of non
22、structural mullions and mullion covers; details of anchoring and reinforcing nonstructural mullions at windows to receive window cleaner anchors.SECTION 08 51 13 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-6. Number and locations of window
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0851132011ALUMINUMWINDOWS 铝制 窗户 PDF