NAVY UFGS-07 21 23-2011 LOOSE FILL THERMAL INSULATION《松散充填料热绝缘》.pdf
《NAVY UFGS-07 21 23-2011 LOOSE FILL THERMAL INSULATION《松散充填料热绝缘》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-07 21 23-2011 LOOSE FILL THERMAL INSULATION《松散充填料热绝缘》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-07 21 23 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 21 23 (August 2010)UFGS-07 21 23 (February 2010)UFGS-07 21 23 (April 2006)UFGS-07216 (August 2004)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTI
2、ON TABLE OF CONTENTSDIVISION 07 - THERMAL AND MOISTURE PROTECTIONSECTION 07 21 23LOOSE FILL THERMAL INSULATION05/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 SUSTAINABLE DESIGN CERTIFICATION1.4 DELIVERY, STORAGE, AND HANDLING1.4.1 Delivery1.4.2 Storage1.5 SAFETY PRECAUTIONS1.5.1 Respirators1.5.2
3、Smoking1.5.3 Other Safety ConcernsPART 2 PRODUCTS2.1 LOOSE FILL INSULATION2.1.1 Thermal Resistance Value(s) (R-Values)2.1.2 Recycled Material2.1.3 Prohibited Materials2.2 SILL SEALER INSULATION2.3 BLOCKING2.4 VAPOR RETARDER2.5 PRESSURE SENSITIVE TAPEPART 3 EXECUTION3.1 EXISTING CONDITIONS3.2 PREPARA
4、TION3.2.1 Blocking at Attic Vents and Access Doors3.2.2 Blocking Around Heat Producing Devices3.2.3 Protection of Ventilation System3.3 INSTALLATION3.3.1 InsulationSECTION 07 21 23 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.3.2 Attics an
5、d Ceilings3.3.2.1 Frame Walls3.3.2.2 Masonry Walls3.3.2.3 Electrical Wiring3.3.2.4 Cold Climate Requirement3.3.2.5 Special Requirements for Ceilings3.3.2.6 Installation of Sill Sealer3.3.2.7 Access Panels and Doors3.3.3 Installation of Vapor Retarder- End of Section Table of Contents -SECTION 07 21
6、23 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-07 21 23 (May 2011)-Preparing Activity: NAVFAC SupersedingUFGS-07 21 23 (August 2010)UFGS-07 21 23 (February 2010)UFGS-07 21 23 (April 2006)UFGS-07216 (Augu
7、st 2004)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2011*SECTION 07 21 23LOOSE FILL THERMAL INSULATION05/11*NOTE: This guide specification covers the requirements for loose fill cellulosic and mineral fiber insulation materials in attics, ceilings, and fr
8、amed walls and mineral granular in masonry walls.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, del
9、eting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcom
10、e and should be submitted as a Criteria Change Request (CCR).*NOTE: This guide specification is intended for both retrofit of existing buildings and new construction.*NOTE: On the drawings, show:1. Locations where insulation will be used.2. Thermal resistance value (R-Value) for each location.3. Loc
11、ation of vapor retarder, if required.SECTION 07 21 23 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4. Location and size of attic ventilation openings where required.*NOTE: Attic VentilationProvide net, unobstructed ventilation areas to attic
12、s over insulated ceilings:1. For attics with vapor retarder, provide 0.1 square meter one square foot of net ventilation area for each 30 square meters 300 square feet of attic floor area.2. For attics without vapor retarder, provide 0.1 square meter one square foot of net ventilation area for each
13、15 square meters 150 square feet of attic floor area.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization,
14、designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not u
15、sed in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the tex
16、t by the basic designation only.ASTM INTERNATIONAL (ASTM)ASTM C 1015 (2006) Standard Practice for Installation of Cellulosic and Mineral Fiber Loose-Fill Thermal InsulationASTM C 516 (2008) Vermiculite Loose Fill Thermal InsulationSECTION 07 21 23 Page 4Provided by IHSNot for ResaleNo reproduction o
17、r networking permitted without license from IHS-,-,-ASTM C 549 (2006) Perlite Loose Fill InsulationASTM C 665 (2006) Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured HousingASTM C 739 (2008) Cellulosic Fiber Loose-Fill Thermal InsulationASTM C 764 (2007) Mineral
18、 Fiber Loose-Fill Thermal InsulationASTM C 930 (2005) Potential Health and Safety Concerns Associated with Thermal Insulation Materials and AccessoriesASTM D 3833/D 3833M (1996; R 2006) Water Vapor Transmission of Pressure-Sensitive TapesASTM D 4397 (2010) Standard Specification for Polyethylene She
19、eting for Construction, Industrial, and Agricultural ApplicationsASTM E 136 (2011) Behavior of Materials in a Vertical Tube Furnace at 750 Degrees CASTM E 84 (2010b) Standard Test Method for Surface Burning Characteristics of Building MaterialsASTM E 96/E 96M (2010) Standard Test Methods for Water V
20、apor Transmission of MaterialsGREENGUARD ENVIRONMENTAL INSTITUTE (GEI)GEI Greenguard Standards for Low Emitting ProductsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 211 (2010) Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning AppliancesNFPA 31 (2011) Standard for the Installation o
21、f Oil-Burning EquipmentNFPA 54 (2009; TIA 10-3) National Fuel Gas CodeNFPA 70 (2011) National Electrical CodeSCIENTIFIC CERTIFICATION SYSTEMS (SCS)SCS Scientific Certification Systems (SCS)Indoor AdvantageTECHNICAL ASSOCIATION OF THE PULP AND PAPER INDUSTRY (TAPPI)TAPPI T803 OM (2010) Puncture Test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0721232011LOOSEFILLTHERMALINSULATION 松散 充填 绝缘 PDF

链接地址:http://www.mydoc123.com/p-984720.html