1、INCH-POUND MIL-DTL-32087C (OS) 04 March 2011 SUPERCEDING MIL-DTL-32087B 09 June 2005 DETAIL SPECIFICATION INFLATION DEVICE, AUTOMATIC, FLU-8B/P AND FLU-9B/P This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all departments an
2、d agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This document gives the requirements for the manufacture, assembly, and packaging of the inflation device, automatic, FLU-8B/P and FLU-9B/P and the methods of inspection and tests upon which product acceptance will be based. 2. APPLICABLE
3、DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to
4、ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following s
5、pecifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Comments, suggestions, or questions on this document should be addressed to DEPARTMENT OF TH
6、E NAVY, Indian Head Division, NSWC, Code E12AP, Document Control, 4123 Artisans Court, Suite 103, Indian Head, Maryland 20640-5085, OFFICIAL BUSINESS, or emailed to amanda.pennnavy.mil. Since contact information can change, you may want to verify the currency of this information using the ASSIST Onl
7、ine database at https:/assist.daps.dla.mil. AMSC N/A FSC 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32087C (OS) 2 STANDARDS DEPARTMENT OF DEFENSE MIL-
8、STD-1168 Ammunition Lot Numbering and Ammunition Data Cards DOD-STD-2101 Classification Of Characteristics (Copies of these documents are available online at https:/assist.daps.dla.mil/ or from the Standardization Documents Order Desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094) 2.2.2
9、 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation or contract. DRAWINGS Naval Air System
10、s Command 30003-849AS103 Battery, Dry Storage 30003-849AS153 Inflation Device, Automatic FLU-8B/P 30003-849AS221 Inflation Device, Automatic FLU-9B/P SPI 520-174-0272 Packaging for Inflation Device (Application for copies should be addressed to the DEPARTMENT OF THE NAVY, Indian Head Division, NSWC,
11、 Code E12P, Document Control, 4123 Artisans Court, Suite 103, Indian Head, Maryland 20640-5085, OFFICIAL BUSINESS.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are thos
12、e cited in the solicitation or contract. American Society for Testing Materials ASTM E 1742 Standard Practice for Radiographic Examination ( Copies of this document are available online at http:/www.astm.org or from the American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshoho
13、cken, PA 19428-2959) American Society for Quality ASQ Z1.4 Sampling Procedures and Tables for Inspection by Attributes (Copies of this document are available online at http:/www.asq.org/ or from the American Society for Quality, PO Box 3005, 611 E. Wisconsin Ave., Milwaukee, WI 53201-4606.) Provided
14、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32087C (OS) 3 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this do
15、cument takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.3.2. 3.2 Gen
16、eral. The FLU-8B/P and FLU-9B/P Inflation Devices shall be manufactured in accordance with Drawing 30003-849AS153, or Drawing 30003-849AS221 and all documents and drawings listed thereon. Lot numbers shall be in accordance with MIL-STD-1168. 3.3 Product Baseline. The manufacturer shall maintain a pr
17、oduct baseline list. The list shall be complete, specifying each item used in the FLU-8B/P and FLU-9B/P. The list shall contain for each item: The Description, Part Number, or Identifying Number, Revision letter, and material and/or applicable specification. This list and subsequent revisions shall
18、be submitted for technical review and shall be approved in writing by the Government Design Activity (Naval Surface Warfare Center, Indian Head, MD 20640-5035). Only FLU-8B/P and FLU-9B/P assemblies conforming to this specification and approved product baseline list will be accepted for delivery. 3.
19、4 Primary components. For the purposes of this specification, the Explosive Component is defined as a primary component (see 4.3.3). 3.4.1 Explosive Component. For the purposes of this specification, the following Explosive Components are defined as primary components (see 4.3.3). 3.4.1.1 CONAX Desi
20、gn. For Conax P/Ns 1812-173-02 and 1812-181-01, Primer P/N CC- 114-01 is defined as a primary component. 3.4.1.2 STRATUS Design. For Stratus P/Ns 01-0-04-100-0AA and 01-0-04-200-0AA, EED Assembly P/N 15-9-04-110-0AA is defined as a primary component. 3.4.2 Inspections. Prior to installation in the i
21、nflation devices each Explosive Component shall be subjected to the following inspections. 3.4.2.1 Bridgewire Resistance. The bridgewire resistance of each explosive component shall be tested per 4.6.1 prior to installation. 3.4.2.1.1 CONAX Design. For Primer P/N CC-114-01, the bridgewire resistance
22、 shall be between 2.0 and 5.0 ohms. 3.4.2.1.2 STRATUS Design. For EED Assembly P/N 15-9-04-110-0AA, the bridgewire resistance shall be 3 1.0 ohms. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-32087C (OS) 4 3.4.2.2 Radiographic Inspection.
23、The Explosive Components shall be free of imperfections when examined in accordance with 4.6.2. 3.4.2.3 Ballistic Acceptance Tests. The Explosive Components shall have been ballistically tested and accepted per the contractors acceptance procedure as approved by the Government Design Activity. 3.5 B
24、attery. Batteries shall be per Drawing 30003-849AS103 and shall have been manufactured within 12 months of the delivery date. Batteries shall be included, but not installed, with inflators delivered for first article and lot acceptance test conformance inspection. 3.6. Elastomeric Materials. Elastom
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILDTL32087C2011INFLATIONDEVICEAUTOMATICFLU8BPANDFLU9BPFLU8BP FLU9BP 自动 膨胀 装置 PDF

链接地址:http://www.mydoc123.com/p-978783.html