1、MIL-A-813b7 12 7779706 0357202 3 - . - I -k+: - * . . . MIGA-8 1369 (AS) %-June 1970 I MILITARY SPECIFICATION ASSEMBLY, LEFT-RIGHT STATION I - 6 SA 13 2 F 6 d This speoifioation has been approved by the Naval Air Systems Command, Department of the Navy. 1. SCOPE 1.1 Soope - The equipment oovered by
2、this specifloation ehall be oapable of providing release signals to one left and one right weapons station, Classification - Left-right station assembly 66A132F5 ahall oomirt of the , 1 2 item Usted in 6.9. 2, APPLICABLE DOCUMENTS 2.1 General - The dooumenta listed in 6.11 of the issue in effeot on
3、the date of invitation for bids form 8 part of this speoifioaton to the extent; 6pedfied herein. .I 3. REQUIREMENT8 3.1 Frexmduotion - This rrpeoifoation makes provieion for preproduotion . testing. 3.2 Parta and Materials - In the eelection of parts and materiala, fulfillment of major design object
4、ives shall be the prime ooneideration. in BO doing the foliowing shall govern: (1) Mioraelectronic items shall conform to requirement8 epecified herein. Other parte and materials requirements which can be used interchangeably. The choice of microelectronic modular assemblies shall be basedon 3.2.3 M
5、odules, Maintenance - The electronic portions of the equipment shall be divided into maintenance modules (see Specification MIL-S-23603). Maintenance modules shall normally be considered repairable. 3.2.4 Microelectronic Interchangeability - Microelectronic circuits (MICS) shall be interchangeable a
6、t the ME level, or at the maintenance module level when approved by the procuring activity (see 6.13). 3.3 Design and Construction - The equipment shall conform with all the ap plicabe requirements of Specification MILE- 5400 for design, construction and workman- ship, except as otherwise specified
7、herein. 3.3.1 Total Weight - The total weight of the equipment, excluding cables, shall be a minimum consistent with good design and shall not exceed 3.5 ounces. 3.3.2 Reliability - 3.3.2.1 Operational Stability - The equipment shall operate with satisfactory performance, continuously or intermitten
8、tly for a period of at least 1,000 hours without the necessity for readjustment of any controls which are inaccessible to the operator during normal use. 3.3.2.2 Operating Life - The equipment shall have total operating life of 10,000 hours with reasonable servicing and replacement of parts. placeme
9、nt shall be specified by the contractor. Parts requiring scheduled re- 3.3.2.3 Reliability in Mean Time Between Failure (MTBF) - The equipment shall havq2,000 hours of mean (operating) time between failures when tested and accepted as out- lined under the requirements of 4.4.3. -k- 3.3, 9 Y -_ -ri-
10、_. -z L.: - - i? .I - - - -_I -_ Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- _ . MIL-A-81369 12 9999906 0359205 9 MIL-A-8 1369 (AS) 3.3.10 Primary input Power Requirements - The unit shall operate with the following d-c input power: (i) DC Power
11、 28V, Category l1Bl1, O. 5 amp as specified in MIGSTD-704. (2) DC Power +1OV, O. 5 amp (3) DC Power -1OV, O. 1 amp Degraded Performance - Degraded performance will be permitted for 3.3.10.1 voltage transients not exceeding O. 5 second during normal electric system operation. Operation shall return t
12、o normal with no resulting damage to the equipment. 3.4 Performance - Unless otherwise specified, values set forth to establish the requirements for satisfactory performance apply to performance under both standard and extreme service conditions. When reduced performance under the extreme conditions
13、 is aoceptable tolerances or values setting forth acceptable variations from the performance under the standard conditions will be specified. 3.4.1 Operation - The assembly provides the necessary fire puise(s) for stores release to a left station and a corresponding right station. 3.4.2 Operational
14、Requirements - The assembly shall meet the operational .requirements of 3.4.2.1, subject to the operating conditions shown on figure 1 and the following definition of terms: (1) The logic 0 level for each output shall be less than O. 5 volt dc. (2) The logic 1 level for the outputs shall be as follo
15、ws: Outputs : Terminal: 111 Level Between +5 volts dc and the +10 volt dc input. 4, 19 Between +4. 5 and +7. O volts dc. 3, T, F, 16 -. Between +5,8 and 7. 8 volts dc. E, 17 Between +20 volts dc and the +28 volt dc input. .? . 2: 3.4.2.1 Outputs. . , -. (i) Terminal 7. The output at terminal 7 shall
16、 be at the logic 0 level - when switches S5, S6, S7, S8 and S9 are all open, and shall other- to . wise be at the logic 0 level. ._ -. - - Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-(3) (4) MIL-A-L3b7 12 W 7777706 0357206 O Terminal F. The outpu
17、t at terminal F shall be at the logic 0 level when switch S11 is closed and switch S10 is open, and shall other- wise be at the logic 1 level. Terminal 3. The output at terminal 3 shall be at the logic 1 level when switch S11 is closed and switches S10, S19, S20 and S21 are open, and shall otherwise
18、 be at the logic 0 level. Terminal 16. The output at terminal 16 shall be at the logic 0 level when switch S22 is closed and switch S23 is open, and shall other- wise be at the logic 1 level. Terminal T. The output at terminal T shall be at the logic 1 level when switch S22 is closed and switches S1
19、3, 514, S15 and S23 are open, and shall otherwise be at the logic 0 level. Terminal L. The output at terminal L shall be at the logic 0 level when switches Sll and S22 are closed and switches S1, S2, S3, S4, S10 and S23 are open, and shall otherwise be at the logic ll level. Terminal 4. The output a
20、t terminal 4 shall be at the logic 1 level when switch S11 is closed and switches S10 and S18 are open, and one or more of the following conditions exists: a) The output at terminal L is at the logic 01 level; (b) Switch 524 is closed; or (e) Switches S12, 513, 514 and S15 are open; . otherwise, the
21、 output at terminal 4 shall be at the logic 0 level. Terminal E. terminal 4. The output at terminal E shall be the logic inverse of Terminal 19. The output at terminal 19 shall be at the logic 1 level when switch S22 is closed and switches S18 and S23 are open, and when one or more of the following
22、conditions exists: (a) The output at terminal Lis at the logic 0 level; ) Switch S24 is closed; or (c) Switches S16, S17, S18, S19 and S20 are open; otherwise the output at terminal 19 shall be at the logic 0 level. (10) Terminal 17. The output at terminal 17 shall be the logic inverse of iour- rent
23、 and ambient and surface temperatures. The ambient and surface temperature shall $ (1) On completion of the life test, the equipment shall be reworked by the contractor by replacing all “wear“ items. The “wear“ item-s procuring activity. J shall be determined by agreement between the contractor and
24、de-. . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-A-3369 12 W 9999906 0359234 T W - MIL-A-81369 (AS) (2) After reworking, tlie contractor shall resubinit tlie equipment for acceptance. 4. G Test Procedures - The procedures used for conductin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILA813691970ASSEMBLYLEFTRIGHTSTATION65A132F565A132F5 左右 座位 装配 PDF

链接地址:http://www.mydoc123.com/p-977073.html