KS C IEC 61852-2007 Medical electrical equipment-Digital imaging and communications in medicine(DICOM)-Radiotherapy objects《医用电气设备 医用数字成像和通信(DICOM) 放射治疗设备》.pdf
《KS C IEC 61852-2007 Medical electrical equipment-Digital imaging and communications in medicine(DICOM)-Radiotherapy objects《医用电气设备 医用数字成像和通信(DICOM) 放射治疗设备》.pdf》由会员分享,可在线阅读,更多相关《KS C IEC 61852-2007 Medical electrical equipment-Digital imaging and communications in medicine(DICOM)-Radiotherapy objects《医用电气设备 医用数字成像和通信(DICOM) 放射治疗设备》.pdf(86页珍藏版)》请在麦多课文档分享上搜索。
1、 KSKSKSKSKSKSKSK KSKSKS KSKSK KSKS KSK KS KS C IEC 61852 (DICOM) KS C IEC 61852: 2007(2012 ) 2007 11 29 http:/www.kats.go.krKS C IEC 61852: 2007 : ( ) ( ) ( ) : (http:/www.standard.go.kr) : :2007 11 29 :2012 12 20 2012-0725 : : ( 02-509-7294) (http:/www.kats.go.kr). 10 5 , . KS C IEC 61852: 2007 i .
2、1 3: .1 1 1 2 2 3.X (Radiotherapy) .2 4 (Symbols and abbreviations) .2 A.U RT (RT image INFORMATION OBJECT DEFINITION).6 A.U.1 RT IOD (RT image IOD discription) 6 A.U.2 RT IOD (RT image IOD entity-relationship model) .6 A.V RT (RT DOSE INFORMATION OBJECT DEFINITION).9 A.V.1 RT IOD .9 A.V.2 RT IOD (R
3、T Dose IOD entity-relationship model).9 A.V.3 RT IOD 9 A.W RT (RT STRUCTURE SET INFORMATION OBJECT DEFINITION).11 A.W.1 RT IOD .11 A.W.2 RT IOD .11 A.W.3 RT IOD 11 A.X RT (RT PLAN INFORMATION OBJECT DEFINITION)12 A.X.1 RT IOD .12 A.X.2 RT IOD .12 A.X.3 RT IOD (RT Plan IOD Module Table).12 A.X.3.1 RT
4、 (RT FRACTION SCHEME MODULE)13 A.X.3.2 RT (RT PRESCRIPTION MODULE).13 A.X.3.3 RT (RT TOLERANCE TABLES MODULE).13 A.X.3.4 RT (RT PATIENT SETUP MODULE) 14 C.7.3.1.1.1 (Modality) 14 C.8.X (radiotherapy) .14 C.8.X.1 RT (RT series module)14 C.8.X.1.1 (modality) .15 C.8.X.2 RT (RT image module) .15 C.8.X.
5、2.1 (Multi-frame image data) 21 C.8.X.2.2 X (X-Ray image receptor angle)21 C.8.X.2.3 RT SID(image plane pixel spacing and RT image SID) 21 C.8.X.2.4 (exposure sequence)21 C.8.X.2.5 (single frame and multi-frame images) 22 C.8.X.2.6 (image pixel module attributes)22 C.8.X.2.6.1 (samples per pixel)22
6、C.8.X.2.6.2 (photometric interpretation)22 C.8.X.2.6.3 (bits allocated).22 C.8.X.2.6.4 (bits stored) .22 KS C IEC 61852: 2007 ii C.8.X.2.6.5 (high bit) 22 C.8.X.2.6.6 (pixel representation) 22 C.8.X.3 RT (RT dose module) .22 C.8.X.3.1 (normalization point) 25 C.8.X.3.2 (grid frame offset vector).25
7、C.8.X.3.3 (dose units) 25 C.8.X.3.4 (image pixel module attributes)25 C.8.X.3.4.1 .25 C.8.X.3.4.2 .25 C.8.X.3.4.3 25 C.8.X.3.4.4 26 C.8.X.3.4.5 26 C.8.X.3.4.6 26 C.8.X.4 RT DVH (RT DVH Module)26 C.8.X.4.1 (referenced structure set sequence) 27 C.8.X.4.2 DVH ROI (DVH ROI contribution type)28 C.8.X.5
8、(structure set module)28 C.8.X.5.1 (frames of reference)30 C.8.X.5.2 (frame of reference transformation matrix).30 C.8.X.6 ROI (ROI contour module)31 C.8.X.6.1 (contour geometric type)32 C.8.X.6.2 (contour slab thickness) .32 C.8.X.7 RT ROI (RT dose ROI module)32 C.8.X.7.1 ROI 33 C.8.X.7.2 ROI .33 C
9、.8.X.7.3 .33 C.8.X.8 RT ROI .33 C.8.X.9 RT .36 C.8.X.9.1 (referenced structure set sequence) 37 C.8.X.10 RT 37 C.8.X.10.1 (target underdose volume fraction).39 C.8.X.11 RT (RT tolerance tables module)39 C.8.X.12 RT .41 C.8.X.13 RT (RT fraction scheme module).42 C.8.X.14 RT 46 C.8.X.14.1 (meterset ca
10、lculations) .57 C.8.X.14.2 (planned verification image sequence) 57 C.8.X.14.3 X (X-ray image receptor angle) .58 C.8.X.14.4 (multiple aperture blocks) .58 C.8.X.14.5 (control point sequence) .58 C.8.X.14.6 (absolute and relative machine coordinates)59 C.8.X.14.7 (cumulative dose reference coefficie
11、nt)59 C.8.X.14.8 (machine rotations) 59 C.8.X.15 RT (RT brachy application setups module) 59 C.8.X.15.1 (permanent implants).66 C.8.X.15.2 ROI (referenced ROI number) 66 C.8.X.15.3 (channel length) .66 KS C IEC 61852: 2007 iii C.8.X.15.4 (oscillating source movement)66 C.8.X.15.5 (channel shields)66
12、 C.8.X.15.6 (time calculations)66 C.8.X.15.7 (brachy control point sequence) .67 C.8.X.15.8 (source transit time) 68 C.8.X.15.9 (control point relative position) 68 C.8.X.15.10 3D (control point 3D position)68 C.8.X.15.11 (cumulative dose reference coefficient)68 C.8.X.16 (approval module).69 4: SOP
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- KSCIEC618522007MEDICALELECTRICALEQUIPMENT DIGITALIMAGINGANDCOMMUNICATIONSINMEDICINEDICOM RADIOTHERAPYOBJECTS

链接地址:http://www.mydoc123.com/p-816818.html