ITU-T L 156-2018 Air-assisted installation of optical fibre cables (Study Group 15).pdf
《ITU-T L 156-2018 Air-assisted installation of optical fibre cables (Study Group 15).pdf》由会员分享,可在线阅读,更多相关《ITU-T L 156-2018 Air-assisted installation of optical fibre cables (Study Group 15).pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.156 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (03/2018) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE P
2、LANT Optical fibre cables Guidance and installation technique Air-assisted installation of optical fibre cables Recommendation ITU-T L.156 ITU-T L-SERIES RECOMMENDATIONS ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY EFFICIENCY; CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER EL
3、EMENTS OF OUTSIDE PLANT OPTICAL FIBRE CABLES Cable structure and characteristics L.100L.124 Cable evaluation L.125L.149 Guidance and installation technique L.150L.199 OPTICAL INFRASTRUCTURES Infrastructure including node elements (except cables) L.200L.249 General aspects and network design L.250L.2
4、99 MAINTENANCE AND OPERATION Optical fibre cable maintenance L.300L.329 Infrastructure maintenance L.330L.349 Operation support and infrastructure management L.350L.379 Disaster management L.380L.399 PASSIVE OPTICAL DEVICES L.400L.429 MARINIZED TERRESTRIAL CABLES L.430L.449 For further details, plea
5、se refer to the list of ITU-T Recommendations. Rec. ITU-T L.156 (03/2018) i Recommendation ITU-T L.156 Air-assisted installation of optical fibre cables Summary Recommendation ITU-T L.156 describes air-assisted methods for installation of optical fibre cables in ducts. These methods can be used to i
6、nstall microcables into microducts, or larger cables into ducts or conduits. Installing conditions and equipment required should be different in each case. History Edition Recommendation Approval Study Group Unique ID* 1.0 ITU-T L.156/L.57 2003-05-14 6 11.1002/1000/6321 2.0 ITU-T L.156 2018-03-16 15
7、 11.1002/1000/13566 Keywords Air-assisted installation, air cooler, blowing, blown-in element, blown installation, cable insertion, coefficient of friction, compressor, crash test, duct, leakage piston, microcable, microduct, microelement, micro fibre unit, optical fibre cable, shuttle. * To access
8、the Recommendation, type the URL http:/handle.itu.int/ in the address field of your web browser, followed by the Recommendations unique ID. For example, http:/handle.itu.int/11.1002/1000/11830-en. ii Rec. ITU-T L.156 (03/2018) FOREWORD The International Telecommunication Union (ITU) is the United Na
9、tions specialized agency in the field of telecommunications, information and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendation
10、s on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval
11、of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“
12、is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure, e.g., interoperability or applicability) and compliance wi
13、th the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is requir
14、ed of any party. INTELLECTUAL PROPERTY RIGHTSITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectua
15、l Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. Howev
16、er, implementers are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2018 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the pri
17、or written permission of ITU. Rec. ITU-T L.156 (03/2018) iii Table of Contents Page 1 Scope . 1 2 References . 1 3 Definitions 1 3.1 Terms defined elsewhere 1 3.2 Terms defined in this Recommendation . 1 4 Abbreviations and acronyms 2 5 Conventions 2 6 Installation of jacketed cables in ducts . 2 6.
18、1 Considerations when installing cable . 2 6.2 Variants of air-assisted installation 3 6.3 Operations . 4 7 Installation of microcables in microducts . 5 Appendix I Indian experience: Installation of optical fibre cables by air blowing method 6 I.1 Products required for air-assisted installation of
19、OFC . 6 I.2 Duct 6 I.3 Air-blowing machine 6 I.4 Advantages of air-assisted installation of OFC 6 I.5 Method to measure co-efficient of friction . 7 Bibliography. 8 iv Rec. ITU-T L.156 (03/2018) Introduction Air-assisted installation is based on forcing a continuous high-speed airflow along the cabl
20、e with an air source. The force of the moving air pushes the cable and makes it advance forward at a typical speed supported by the equipment. Generally, the tensile load on the cable is an order of magnitude lower than the typical force involved with other installation methods, like pulling techniq
21、ues, thus reducing installation hazards. Additionally, with this technique, bends in duct runs have somewhat less effect than with pulling techniques, so that installation speed increases and longer lengths of cable can be installed. Cables are installed virtually without stress, leaving the cable e
22、ffectively relaxed in the duct upon completion of the installation. There are several variants of air-assisted installation: with/without a piston at the front end of the cable, or with a leaking piston. For variants without a piston, there is no pulling force at the front end of the cable; airflow
23、exerts a distributed force along the entire cable. In addition, the connection to a pulling cord is not needed. Rec. ITU-T L.156 (03/2018) 1 Recommendation ITU-T L.156 Air-assisted installation of optical fibre cables 1 Scope This Recommendation describes air-assisted methods for installation of opt
24、ical fibre cables in ducts. These methods can be used to install microcables into microducts, or larger cables into ducts or conduits. Installing conditions and equipment required should be different in each case. 2 References The following ITU-T Recommendations and other references contain provisio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL1562018AIRASSISTEDINSTALLATIONOFOPTICALFIBRECABLESSTUDYGROUP15PDF

链接地址:http://www.mydoc123.com/p-799417.html