FORD FLTM BU 153-01-2005 RHEOLOGICAL TESTING FOR DETERMINING THE VISCOSITY OF ADHESIVES AND SEALERS《胶粘剂和密封剂的粘性的流变性试验法测定》.pdf
《FORD FLTM BU 153-01-2005 RHEOLOGICAL TESTING FOR DETERMINING THE VISCOSITY OF ADHESIVES AND SEALERS《胶粘剂和密封剂的粘性的流变性试验法测定》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BU 153-01-2005 RHEOLOGICAL TESTING FOR DETERMINING THE VISCOSITY OF ADHESIVES AND SEALERS《胶粘剂和密封剂的粘性的流变性试验法测定》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHODBU 153-01Printed copies are uncontrolled Copyright 2005, Ford Global Technologies, LLC Page 1 of 4 RHEOLOGICAL TESTING FOR DETERMINING THE VISCOSITY OF ADHESIVES AND SEALERS Application This method is used to evaluate the viscosity of adhesives and sealers as a function o
2、f shear rate. Such properties help to optimize the processing of these materials throughout the manufacturing process, particularly in the flow of these materials through the dispensing system, from the pump to the nozzle. Apparatus Required Rheometer An extrusion rheometer, equipped with an orifice
3、 of 0.32 cm diameter and at least 3.2 cm length. The rheometer should be capable of determining the rheological properties of substances that will flow at room temperature with the application of pressure from 0 to 100 psi, in a viscosity range of 1 to 1 million centipoises. For example, Burrell Sev
4、ers Model A120 Rheometer equipped with an orifice of 0.32 cm inner diameter and 5 cm length, and a sample cylinder of 4 cm inner diameter and 29.5 cm length. (Figure 1) Temperature Control Devices (a) An oven capable of achieving a temperature range of 100 125 F +/- 2 F (b) A refrigerator or freezer
5、 capable of achieving a temperature of 54 F +/- 2 F Miscellaneous (a) Balance to make weight measurements (b) Thermocouple or similar device to make temperature measurements. For example, Omega Thermocouple Probe machined into rheometer sample cylinder, to measure material temperature (Figure 1) (c)
6、 Paper cups (d) Stopwatch Materials Required Adhesive/Sealer Adhesives and sealers (Ford specifications WSB-M4G60-B4, WSB-M4G348-A/A2, WSS-M4G348-A3/A4 and WSB-M2G388-A) will be tested according to this test method. Conditioning and Test Conditions All test values indicated herein are based on mater
7、ial conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5% relative humidity for not less than 24 h prior to testing. Materials will be tested at 23 C unless otherwise stated. Date Action Revisions 2005 03 08 Activated M. Brutto FORD LABORATORY TEST METHODBU 153-01Printed copies are unco
8、ntrolled Copyright 2005, Ford Global Technologies, LLC Page 2 of 4 Procedure 1. Load material into rheometer and attach orifice of 0.32 cm diameter. Fill the orifice with material by applying a small amount of pressure. 2. Three different tests should be run under the following conditions: a. Test O
9、ne: Room Temperature Testing - 23 25 C (73 77 F) 1. Extrude material through orifice into a paper cup, for 1 minute, at the following pressures: a. 5 psi b. 10 psi c. 20 psi d. 30 psi e. 50 psi f. 70 psi g. 90 psi 2. For each pressure, record the weight of material extruded in 1 minute. 3. Run three
10、 replicates per pressure. b. Test Two: Elevated Temperature Testing - 43 46C (110 115F) 1. Condition the rheometer sample cylinder in an oven for 30 minutes at 52 C (125 F). Remove sample cylinder from oven and run test listed in Step 2 below, while maintaining a material temperature of 43 46 C (110
11、 115 F). Material temperature should be monitored throughout the experiment using a thermocouple probe or similar device. Generally, two pressures can be run at one time; then sample cylinder should be re-conditioned in an oven for an additional 30 minutes at 52 C (125 F). 2. Extrude adhesive throug
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBU153012005RHEOLOGICALTESTINGFORDETERMININGTHEVISCOSITYOFADHESIVESANDSEALERS 胶粘剂 密封剂 粘性 流变 试验

链接地址:http://www.mydoc123.com/p-747555.html