FORD FLTM BI 110-03-2000 MEASUREMENT OF DISTINCTNESS OF IMAGE OF PAINTED SURFACES《涂漆表面的图像的明晰度的测定》.pdf
《FORD FLTM BI 110-03-2000 MEASUREMENT OF DISTINCTNESS OF IMAGE OF PAINTED SURFACES《涂漆表面的图像的明晰度的测定》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BI 110-03-2000 MEASUREMENT OF DISTINCTNESS OF IMAGE OF PAINTED SURFACES《涂漆表面的图像的明晰度的测定》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BI 110-03 Date Action Revisions 2000 08 31 Revised Editorial no technical change A. Cockman 1996 10 02 Printed copies are uncontrolled Page 1 of 6 Copyright 2000, Ford Global Technologies, Inc. MEASUREMENT OF DISTINCTNESS OF IMAGE OF PAINTED SURFACES Application This pro
2、cedure is used for measuring the distinctness of image (D.I.) of painted surfaces with a beam of incident light at an angle of 30 +/ - 3 degrees. Materials and Apparatus Required Dorigon Glossmeter D47R - 6F Dorigon meter (optical sender and signal processor).* Primary Standards A highly polished, p
3、lane, black glass surface with an assigned D.I. value.* Secondary Standard A semi - gloss ceramic tile with an assigned D.I. value.* * Source: Hunter Associates Laboratory, Inc. Fairfax, Virginia U.S.A. Soap - liquid, neutral. Deionized or Distilled Water - 10 ppm max dissolved solids (ASTM D 1888).
4、 Panels As specified in FLTM BI 103 -02 (for spray systems), or FLTM BI 120 - 01 (for e lectrocoat systems), or as specified in the applicable engineering document. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/
5、 - 2 C and 50 +/ - 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BI 110-03 Page 2 of 6 Co pyright 2000, Ford Global Technologies, Inc. Procedure Sample Preparation 1. Prepare paint panels per
6、 FLTM BI 103 - 02 or BI 120 -01, or specified by the applicable engineering document. 2. Wash the panels, if soiled, with neutral liquid soap and water, rinse with deionized or distilled water and blow off with air. Standardization 1. Release the standby button on the Glossmeter and allow the meter
7、to warm up for 15 minutes. 2. Screw the three alignment posts into the port collar. 3. Place the optical sensor in the cradle, with the specimen port facing upward. 4. Place the primary standard on the specimen port with the beam directional arrows in the same direction. 5. Press the R s button on t
8、 he signal processor (all other buttons must be in the released position). 6. Using the adjustment knob on the optical sensor, adjust until the digital readout shows the maximum R s reading. 7. Use the standardize control knob on the processor to adjust th e digital display in order to read the cali
9、brated R s value of the primary standard. 8. Press the D.I. button. If the value displayed is not within +/ - 1.0 of the assigned D.I. value, refer to Attachment A. 9. Place the secondary standard on the specimen port and press the R s button. 10. Adjust the maximum reading on the digital display by
10、 means of the adjustment knob on the end of the optical sensor. If the value is not within +/ - 2.0 of the calibrated R s value of the secondary standard, refer to Attac hment A. Note: Position and cleanliness of this standard is critical. 11. Press the D.I. button. If the value displayed is not wit
11、hin +/ - 3.0 of the calibrated D.I. of the secondary standard, refer to Attachment A. FORD LABORATORY TEST METHOD BI 110-03 Page 3 of 6 Co pyright 2000, Ford Global Technologies, Inc. Measuring D.I. - Test Panels 1. Pl ace the top of the test panel on the specimen port against the alignment posts. 2
12、. Press the D.I. button. 3. Adjust for the maximum positive display reading by means of the knob at the end of the optical sensor. 4. Read the D.I. value on the display and record. 5. Place the bottom of the test panel on the specimen port and repeat steps 1 through 4. 6. The D.I. for the panel shal
13、l be the average of the readings from the top and bottom of the test panel . Measuring D.I. - Vehicles 1. Remove the alignment p osts from the optical sensor viewing port. 2. Place the optical sensor on the vehicle. The arrow on the optical sensor must be pointed to the front of the vehicle. Note: W
14、hen measuring the hood, locate the optical sensor approximately 300 mm from the c owl and 300 mm outboard of the center line. Measure the right and left side, average the readings and record individual and average values. When measuring the deck lid, locate the optical sensor approximately 300 mm fr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBI110032000MEASUREMENTOFDISTINCTNESSOFIMAGEOFPAINTEDSURFACES 涂漆 表面 图像 明晰 测定 PDF

链接地址:http://www.mydoc123.com/p-746985.html