ETSI EN 300 394-4-12-2001 Terrestrial Trunked Radio (TETRA) Conformance Testing Specification Part 4 Protocol Testing Specification for Direct Mode Operation (DMO) Sub-Part 12 Test.pdf
《ETSI EN 300 394-4-12-2001 Terrestrial Trunked Radio (TETRA) Conformance Testing Specification Part 4 Protocol Testing Specification for Direct Mode Operation (DMO) Sub-Part 12 Test.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 394-4-12-2001 Terrestrial Trunked Radio (TETRA) Conformance Testing Specification Part 4 Protocol Testing Specification for Direct Mode Operation (DMO) Sub-Part 12 Test.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、ETSI EN 300 394-4- 1 2 VI .I .I (2001-01) European Standard (Telecommunications series) Terrestrial Trunked Radio (TETRA); Conformance testing specification; Part 4: Protocol testing specification for Direct Mode Operation (DMO); Sub-part 12: Test Suite Structure and Test Purposes (TSS Essential, or
2、 potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server ClattD:/www.etsP.c/iDr. Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ET
3、SI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR O00 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the present document. Foreword This European Standard (Telecommunications series) has been produced by ETSI Proj
4、ect Terrestrial Trunked Radio (TETRA). The present document had been submitted to Public Enquiry as ETS 300 394-4-12. During the processing for Vote it was converted into an EN. The present document is part 4 of a multi-part deliverable covering Terrestrial Trunked Radio (TETRA); Conformance testing
5、 specification, as identified below: Part 1: “Radio“; Part 2: Part 3: Part 4: Part 5: “Security“. “Protocol testing specification for Voice plus Data (V+D)“; “Protocol testing specification for Packet Data Optimized (PDO)“; “Protocol testing specification for Direct Mode Operation (DMO)“; National t
6、ransposition dates Date of adoption of this EN Date of latest announcement of this EN (doa): Date of latest publication of new National Standard or endorsement of this EN (dop/e): Date of withdrawal of any conflicting National Standard (dow): 29 December 2000 31 March 2001 30 September 2001 30 Septe
7、mber 2001 ETSI 5 ETSI EN 300 394-4-1 2 V1.l.l (2001 -01) 1 Scope The present document contains the Test Suite Structure (TSS) and Test Purposes (TPs) to test the TETRA Direct Mode Operation (DMO) protocols. The present document is divided into several parts, each one dealing with a different set of
8、layer 3 and layer 2 DMO protocols. This present part 4, sub-part 12 deals with TSS Technical requirements for Direct Mode Operation (DMO); Part 7: Type 2 repeater air interface“. ETSI EN 300 396-8-4: “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8:
9、Protocol Implementation Conformance Statement (PICS) proforma specification; Sub-part 4: Type 2 repeater Air Interface (AI)“. ISO/IEC 9646-1 (1994): “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 1: General concepts“. (See also ITU-T Rec
10、ommendation X.290). 121 131 141 ISO/IEC 9646-2 (1994): “Information technology - Open Systems Interconnection - Conformance testing methodology and framework - Part 2: Abstract Test Suite specification“. (See also CCITT Recommendation X.291). ETSI ETS 300 406 (1995): “Methods for Testing and Specifi
11、cation (MTS); Protocol and profile conformance testing specifications; Standardization methodology“. ETSI EN 300 396-8-2: “Terrestrial Trunked Radio (TETRA); Technical requirements for Direct Mode Operation (DMO); Part 8: Protocol Implementation Conformance Statement (PICS) proforma specification; S
12、ub-part 2: Type 1 repeater Air Interface (AI)“. ETSI 6 ETSI EN 300 394-4-1 2 V1.l.l (2001 -01) 3 Definitions and abbreviations 3.1 TETRA d ef i nit ions For the purposes of the present document, the terms and definitions given in EN 300 396-7 i apply. 3.2 ISO/IEC 9646 abbreviations For the purposes
13、of the present document, the following ISOAEC 9646-1 3 abbreviations apply: ICs IUT IXIT PDU PICS PIXIT TP TSS Implementation Conformance Statement Implementation Under Test Implementation extra Information for Testing Protocol Data Unit Protocol Implementation Conformance Statement Protocol Impleme
14、ntation extra Information for Testing Test Purpose Test Suite Structure 3.3 TETRA abbreviations For the purposes of the present document, the following TETRA abbreviations apply: CM Circuit Mode DMO Direct Mode of Operation MAC Medium Access Control MS Mobile Station Rx Receiver SDS Short Data Servi
15、ces SDU Service Data Unit 4 Test Suite Structure (TSS) 4.1 MAC layer test groups The first level of the MAC test groups separates the MAC test suite in functional test groups: CA, BV, BI and TI. The following list defines the MAC layer test group names and identifiers: - DM-REP2 MAC layer (DMO-DMREP
16、2MAC) - Capability tests (CA) - Valid behaviour tests (BV) - Invalid behaviour tests (BI) - Timer tests (TI) ETSI 7 TP-Name The TP name is a unique identifier, specified according to the TP naming conventions defined in the clause below. (it is also the name of the corresponding test case) ETSI EN 3
17、00 394-4-1 2 V1.l.l (2001 -01) Requirement ref: reference to the clause number of specification EN 300 396-7 l stating this conformance requirement. For example: EN 300 396-7 l, 6.2.5.1 4.2 Pur pose Selection cond Test description Pass criteria Preamble Postam ble Test g roup descri pt ion purpose o
18、f the test itself, indicating for example the test performed against a requirement of the protocol, described by this test purpose. Example: test of changeover initiated from RX reservation state expression based on EN 300 396-8-4 2 PICS statements, used to select or deselect the corresponding test
19、case according to the options of the implementation. body of the test visible action to be observed at PCO to declare that the IUT passes the test and conforms to the specifications “None“ or name of the preamble procedure bringing the IUTfrom idle state to the state required to run the test. “None“
20、 or name of the postamble to bring the IUT back to idle state. Capability (CA) tests provide limited testing that the observable capabilities of the IUT are in accordance with the conformance requirements and the additional capabilities claimed in the PICSPIXIT. The Valid Behaviour (BV) group tests
21、an IUT in response to valid behaviour of the test system. “Valid“ means that a test event is syntactically and contextually correct. All test cases in the valid behaviour group are intended to verify as thoroughly as possible the various functions of the protocol. Different timers are defined to sup
22、ervise the various state transitions. The Timer (TI) test group is intended to verify that the IUT is reacting properly to an expiry of one of the timers or to a counter mismatch. 5 Introduction to Test Purposes (TPs) The test purposes are defined in clause 6 of the present document for MAC layer. 5
23、.1 Test purpose definition conventions Each TP is described using text presented in a table. Table 1 contains the following information. Table 1 5.2 Test purpose naming conventions The identifier of a test purpose is built according to table 2. Table 2: Test purpose naming convention DMO/4sll = test
24、 suite type DMREP2 DM Repeater type 2 = Type of testing CA BV BI TI I Capability Tests Valid Behaviour Tests Invalid Behaviour Tests Timer expiry and counter mismatch tests lani = sequential number o1 -99 Test Purpose Number ETSI 8 DMO-M SREP2-MAC-CA-O1 ETSI EN 300 394-4-1 2 V1.l.l (2001 -01) Refere
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN3003944122001TERRESTRIALTRUNKEDRADIOTETRACONFORMANCETESTINGSPECIFICATIONPART4PROTOCOLTESTINGSPECIFICATIONFORDIRECTMODEOPERATIONDMOSUBPART12TESTPDF

链接地址:http://www.mydoc123.com/p-728465.html