1、AMSC N/A FSC 5920 INCH-POUND MIL-PRF-15160/60J 15 October 2008 SUPERSEDING MIL-PRF-15160/60H 14 March 2005 PERFORMANCE SPECIFICATION SHEET FUSES, INSTRUMENT, POWER, AND TELEPHONE (NONINDICATING), STYLE F60 This specification is approved for use by all Departments and Agencies of the Department of De
2、fense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-15160. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. FIGURE 1. Style F60, characteristic C. Inches mm .004 0.10 .009 0.23 .031
3、0.79 .406 10.31 1.500 38.10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/60J 2 REQUIREMENTS: Interface and physical dimensions: See figure 1. Case: Glass melamine. Ferrule: Brass, copper, bronze, or copper alloy. Finish: Nickel, or s
4、ilver plated when specified. Terminal strength: Method 211 of MIL-STD-202, test condition E, 2 pound-inch torque between ferrules and fuse body. Electrical: Current rating: See table I. Current carrying capacity: 110 percent of rated current. Voltage rating: See table I. Characteristic: See table I.
5、 Overload interrupt: Within 1 hour at 135 percent of rated current; and within 2 minutes at 200 percent. Short circuit interrupt: 200,000 A at 500 V ac (symmetrical), 150,000 A at 500 V dc. Shock: Method 207 of MIL-STD-202, HI shock. Vibration: Method 204 of MIL-STD-202, test condition A (except 5g,
6、 500 Hz). Type designation: Type designation shall be as specified in table I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/60J 3 TABLE I. Type designation. 1/ 1/ For silver plated terminals, the designator “S“ is added after the cur
7、rent rating. VERIFICATION: Qualification inspections: The number of qualification samples required shall be: a. 24 samples maximum current rating of each voltage and design. b. 24 samples minimum current rating of each voltage and design. NOTE: If labels are used, five additional samples of any rati
8、ng are required. Sample size: The number of group III samples shall be twelve samples each of the maximum and minimum current ratings. The samples shall be divided as shown in table II. TABLE II. Short circuit test. 1/ A 600 volt ac test voltage may be used. Group C inspection: Group C inspection sh
9、all be performed on short circuit current ratings of 5,000 A at 500 V ac; 200,000 A at 500 V ac; and 5,000 A at 500 V dc. The 150,000 A at 500 V dc short circuit current test is not required to be performed for group C testing. Style Characteristic Voltage Current F60 F60 F60 F60 F60 F60 F60 F60 F60
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF1516060J2008FUSESINSTRUMENTPOWERANDTELEPHONENONINDICATINGSTYLEF60PDF

链接地址:http://www.mydoc123.com/p-692207.html